Loading...
HomeMy WebLinkAboutProduct Approval shingles • Ad'01 3 " RECE1Vr:D MAR 0 S IN EXTERIOR RESEARCH& DESIGN, LLC. Certificate of Authorization#9503 Tf�INITY ERD Permitting DepartmentCertificate CHRISTIAN STREET, UNIT#13 St.Lucie County OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL30674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: — �P•E4�; c• . CO:t� _ o-Sgll6 Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCAANE1983 f'�"'��� " ' Nieminen,P.E.on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used foe permitting or design guidance unless retained specifically for that purpose. r' TRINITY'ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme!are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"' are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition. Duration, Duration Premium Cool, TruDefinition' Duration Designer Color Collection, TruDefinition'Oakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard0. HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge`m Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthoriration#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL30674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 i I ' ' TRINITYERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones Up to Vasd= 150 mph (V,,t= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire®shingles require minimum five(5) nails per shingle. WeatherGuard HP shingles require minimum six(6)nails per shingle. Devonshire'"shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltunderlaymem Deck Feltunde+Yyment Deck SaMrAhred w..nherLocrt Self-adhered utrdadaptwn WeatherLocks urderlayment �p Drip edge �p—� '{ Drip edge edge edge Nails located Nalr located 2-r from saw 2"-3"from eave Install Self-sealing adhesive Instil flirt Stutz s S*40*v 40"W Starter positioned along eave Strip Plus positioned along save shingle! with G nmovad 6"removed Starter Strip shingle overhangs eaves and rakes bi"44" Samar Strq P4s overhangs caws and rakes 1p•-7i4' Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area parr* Normal Mansard or Area pan Wind Area" High Wind deavanes y Wind Areas High Wind dasst nae y Area pan virr►tos normaMa Areas r/antor fueress Ana pan Was nonssafaa Areas Wall Iambs n• 12 T g+Po• 6 6/8'Exposure Erpeaiel6n Exposiei6n 6.2.7 Minimum Nailing—Berkshire®: Sealow snip Sealant strip to Ura do saradu U tiro de sellador •�--s • *-------1- 04------------01• 0-0 • 0-0-0 9 th' 9 Yf 1 9 Yf I e Yf "ski, a rh" 8'h" 8 uz" l. r r Standard Fastening Pattern 6-Nail Fastening Pattern Seabnt strip U Ura do sdJadx 041�--�• •Fes►a 4----►• r 8 Vf 8 Yf 8 Yf B r'y 1` a r ♦*-- 2' 1-74 Mphak rooting oonwt Conwnto do bAo do asidto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 =E, TRINITY ERD 6.2.8 Minimum Nailing—Devonshire": 1" 7" 8" 8" 8" 7- Wo uposure "5318'exposure Sealmtlocation i Exposiei6n de 5-5/8 pulp Ubiaci6rl del sellador }I Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration®Designer Color Collection: 4-Nall Fastening Pattern "all Fastening Pattern AeU/arlBMw•rr0anewwo WNaaet tWwnp ane WWO was.typlar I M+a.rypcar +• tr tr r +r trF] r aw sarr �+�saw- Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for 31opes Greater Than 21:12 s.w.r•raa."ww.«.ram rAP r +r +r a-+n-ssra- �r Pour+••P•%at A•PkW r100••e aow"r Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 TRINITY ERD 6.2.1 Minimum Nailing—TruDefinition�Oakridge®,Oakridge®: 4 Nail Pdttern 6 Nail Pattern Esquems con 4 clavos Esquema con 6 davos r t- r r I<— >r —►I iE- tr F/ 65/9 Exposuremails5 6/9"Exposure Nail, &poslddnde66/8pa¢ Claims Exposicimdo56/8pulg. 664rExposule Crams 55/0'Exposule Exposiddn de 5 5/8 ptdg. Exposition de 5 5/8 pulg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 rwa*rpm i• z _� r tr a.in- s.a+• _ 0 F—i-{pw of Asp—nom N CN Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: �illdhfrhtdVbw .t;: •:f• IIrMr�r7bhsh�hNil 1i� Clam JtiJt...'= Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate ofAuthoriration x9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8