HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
Business & Professional Regulation
r
SCIS Home j Log In : User Registration i Hot Topics ; Submit Surcharge ; Stats&Facts j Publications FBC Staff k BCIS Site Map Links ( Search i
f 'tla
Product Approval
R USER:Public User
Product Aooroval Menu>Application Detail
FL# FL21553-R1
Application Type Revision
Code Version 2017
Application Status Validated
Comments
Archived f l
Product Manufacturer Tri-Built Materials Group,LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
U Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Intertek Testing Services NA,Inc. -QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
D Validation Checklist-Hardcopy Received
Certificate of Independence FL21553 R1 COI TBM16001.1 2017 FBC Eval Underlavment flnal.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 226 2009
ASTM D 4533 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://floridabuilding.org/pr/Pr app_dtl.aspx?param=wGEVXQwtDqtcQ%2f8oYOLm9py7... 3/1/2018
Florida Building Code Online Page 2 of 2
Date Submitted 02/21/2018 •
Date Validated 02/21/2018
Summary of Products
FL# Model,Number or Name Description
21553.1 Tri-Built Materials Synthetic Mechanically attached,woven polypropylene underlayments
Underlayments used as alternatives to ASTM D 226,Type I and Type II.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL21553 RI II TBM16001 1 2017 FBC Eval Underlavment
Approved for use outside HVHZ:Yes fin
Impact Resistant: N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL21553 R1 AE TBM16001.1 2017 FBC Eval Underlavment
final.Dd
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
X91 ® hR
Credit Card
Safe
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtcQ%2f8oYOLm9py7... 3/1/2018
Certificate of Authorization No. 29824
GREEK 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL. SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION(2017)
Manufacturer: TRI-BUILT Materials Group Issued February 21, 2018
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485
www.tribuiltmaterialsoroup.com
Quality Assurance: Intertek Testing Services(QUA1586)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1, 1518.4
Properties: Physical properties
REFERENCES
Enth Report No. Standard Year
Intertek Testing Services(TST1585) 102074565COQ-004 AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-004A AC 188' 2012
Intertek Testing Services(TST1585) 102074565COQ-007 ASTM D 226 2009
Intertek Testing Services(CER1497) CCRR-1045 IBC,IRC 2012
PRI Construction Materials Technologies(TST5878) CMI-048-02-01A ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-01B ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-048-02-01C ASTM D 226 2009
PRI Construction Materials Technologies(TST5878) CMI-055-02-01 ASMT D 4533 2015
PRI Construction Materials Technologies(TST5878) CMI-056-02-01 ASMT D 4533 2015
'Determined to be equivalent to ASTM D 226(2009),Type I and II
PRODUCT DESCRIPTION
Tri-Built Synthetic 10 A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic 25 A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic Plus A mechanically attached, woven polypropylene underlayment (nominal weight = 2.46
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
Tri-Built Synthetic MAX A mechanically attached, woven polypropylene underlayment (nominal weight = 3.69
Roof Underlayment Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear
strength per ASTM D 4533 of 20 pounds. The underlayment is available in rolls 48-inch
wide by 250-ft long.
TBM16001.1 FL21553-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CRK TRI-BUILT MATERIALS GROUP
Synthetic Underlayments
TECHNICAL SERVICES,LLC
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing
construction. Sheathing shall be installed in accordance with FBC requirements. New
construction in the HVHZ shall be minimum 19/32-inch plywood. Roof decks shall
have no more than 1/8-inch gap at abutting joints.
Attachment method Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and
(non-HVHZ): manufacturer's installation instructions.
Attachment method Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch
(HVHZ): end lap and be fastened as specified in FBC Section 1518.2.
Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1507.1.1.
(Non-HVHZ):
Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles, metal roof
(HVHZ): panels and shingles, composite shingles and wood shingles and shakes
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Roof slope limitations shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
9) The underlayment shall not be installed over existing roof coverings.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
TBM16001.1 FL21553-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TRI-BUILT MATERIALS GROUP
Synthetic Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
,, PRY R p •,, 2018.02.21
',,,�. •.`'�G E N SF • s�."," ���-._' 1
No 74021 13:42:11
* = -05'00'
3 STATE OF :�Z/
" ��•.�< pP,•'�= Zachary R. Priest, P.E.
'��'�SS;ONpLE�. `,` Florida OrganzationNo.IANE9641on No. 021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBM16001.1 FL21553-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not