HomeMy WebLinkAboutProduct Approval shutter Florida Building Code Online Page 1 of 3
ess •• Professional Regulation
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search
o
�
pr
Product Approval
USER:Public User c-il
Product Aooroval Menu>Product or Aoolication Search>Aonlication List>Application Detail
FL# FL389-R9
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived RECEIVED
Product Manufacturer American Shutter Systems Association, Inc. MAR 0 8 2018
Address/Phone/Email 4268 Westroads Drive
West Palm Beach,FL 33407
(561)209-8263 Permitting Department
bfeeley@easternmetal.com St. Lucie County
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Walter A..Tillit,Jr.P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By John Henry Kampmann Jr.
-/ Validation Checklist-Hardcopy Received
Certificate of Independence FL389 R9 COI AMERICAN SHUTTER SYSTEM ASSOC..INC. DRAWING
17-107 CERTIFICATE OF INDEPENDENCE.PDF
FL389 R9 COI AMERICAN SHUTTER SYSTEMS ASSOC INC
DRAWING 17-106 CERTIFICATION OF INDEPENDENCE(1)PDF
FL 384 R9 COI AMERICAN SHUTTER SYSTEMS DRAWING 17-108
CERTIFICATE OF INDEPENDENCE.PDF
Referenced Standard and Year(of Standard) Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201, 202,203 1994
Equivalence of Product Standards
Certified By
httnc•//www.floridahuilding.org/or/nr ann dtl.asnx?param=wGEVXQwtDgvYYHH2vJvx5... 1/8/2018
Florida Building Code Online Page 2 of 3
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted 09/18/2017
Date Validated 10/18/2017
Date Pending FBC Approval 10/19/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
389.1 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
Blade 3-(Non-HVHZ)- Drwg 17- (top and bottom)for storm protection
108
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL389 R9 II AMERICAN SHUTTER SYSTEMS DRAWING
Approved for use outside HVHZ:Yes 17-108 BERTHA HV ACCORDION SHUTTER SYSTEM.PDF
Impact Resistant:Yes Verified By: American Test Lab of South Florida Inc.
Design Pressure:N/A Created by Independent Third Party: Yes
Other:Large Missile Level"D".Max span is 12'-3"for 40 psf Evaluation Reports
positive ASD load and 13'-0"for 35 psf negative ASD load FL389 R9 AE AMERICAN SHUTTER SYSTEMS DRAWING
the HV3 blade w/o window blade,5'-2"for 110 psf ASD load 17-108 PRODUCT EVALUATION REPORT.PDF
for HV3 blade w/o window blade and 8'-11"for 62 psf,9'- Created by Independent Third Party: Yes
11"for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79"for max.ASD
pressure rating of+72,-72 and 84"for+64,-64 psf.See
sheet 5 for other spans and ASD pressures.
389.2 Bertha HV Accordion Shutter-Blade Extruded aluminum interlocking blades retained by tracks
1 Only-(Non-HVHZ)-Drwg 17-107 (top and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R9 II AMERICAN SHUTTER SYSTEM ASSOC.,
Approved for use outside HVHZ:Yes INC. DRAWING 17-107 BERTHA HV ACCORDION SHUT EE&
Impact Resistant:Yes SYSTEM.PDF
Design Pressure:N/A Verified By: American Test Lab of South Florida Inc.
Other: Large missile level"D". Max. Span is 16'-0"for 30 Created by Independent Third Party:Yes
p.s.f negative ASD load depending on centermates and Evaluation Reports
locking rod configuration for the HV1 blade,8'-0"for+64, FL389 R9 AE AMERICAN SHUTTER SYSTEM ASSOC.,
-72 p.s.f.A.S.D. load for HV blade for Keystone mountings INC, DRAWING, 17-107 PRODUCT OF EVALUATION
7'-0"p.s.f.for metals stud mountings and 8'-0"for 110 REPORT.PDF
p.s.f.for HV1A working in unison.See sheets 7, 11 and 20 Created by Independent Third Party: Yes
respectively of installation drawings for other spans and
pressures.
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO-(Non-HVHZ)-Drwg 17- (top and bottom)for storm protection
106
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R9 II AMERICAN SHUTTER SYSTEMS ASSOC.,
Approved for use outside HVHZ:Yes INC. nRAWING 17-106 BERTHA HV ACCORDION SHUTTER
Impact Resistant:Yes SYST.PDF
Design Pressure: N/A Verified By: American Test Lab of South Florida Inc.
Other: Large missile. Max. 16'-0"span at 30 p.s.f ASD load Created by Independent Third Party: Yes
for Blade 1 and 18'-0"for Blade 2. See schedules on sheet Evaluation Reports
12, 25 and 28 respectively FL389 R9 AE AMERICAN SHUTTER SYSTEMS ASSOC.,
INC DRAWING 17-106 PRODUCT EVALUATION
REPORT.PDF
Created by Independent Third Party: Yes
Bade Vert
Contact Us::7601 Blair Stone Road Tallahassee FL 32349 Phone,850.487-1824
The State of Florida is an AA/EEO employer.r'oovriaht 2007-2013 State of Florida.::Privacy Statement::Aar. hiliN 5 aterrwnt::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
httns://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx5... 1/8/2018