Loading...
HomeMy WebLinkAboutProduct Approval - shingles COPY Business & Professional Regulation r�r�rr SCI,SS�Home I Log In I User Registration Hot Topic Submit Surcharge Stats&Facts Publicatbre Fac stall acts site Map Links Search F Product Approval USER:Public User Product Aooroval Menu>Product or Applkatlpn Search>Application List>Application Detail FL# FL18355-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kern Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_.eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden 21 Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001 4 2017 FBC Eval Reoort Shingles final odf Referenced Standard and Year(of Standard) Standard YAM ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FLIB355 R4 Equiv UL letter for standards for FBC 2017.odf Sections from the Code Product Approval Method Method i Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage,Heritage Premium, Heritage Woodgate,Heritage Vintage,Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18355 R4 II TBP15001.4 2017 FBC Eyal Report ShIngles Approved for use outside HVHZ:Yes final.Ddf Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other: See evaluation report for limits of use. Evaluation Reports FLIB355 R4 AE TBP3 001 4 2017 Far Eval Report Shingles flnal.Ddf Created by Independent Third Party:Yes Back Next Contact us::2601 Blair Stone Road,Tallahassee FL 3 399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::A¢essibdity Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send elearonlc mall to this entity.Instead,contact the oMce by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,Ikensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Proalru"Approlml Aeeepb- ®IBJ® --. Credit Card Safe Certificate of Authorization No. 29824 GREEK 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017 220 West 4"Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO Phillipsburg,KS Frederick, MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES _ Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) IOCA50498 ASTM D 3462 2010A UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. use or other product attributes that are not This evaluation report does not express nor imply warranty, installation, recommendedp specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36', ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4' x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed (V„n): Max. 194 mph (Frederick, Joplin& Basic Wind Speed (Vad): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin (Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nall Pattern"or"6 Nail Pattern"detailed below. NAILS 1" 1" Nailing -- ........ - - - - ------------ Area -- x-7/8" Area ------------------------------... ------------_.........__.. - ----.--------------._..... _ 5-118" t Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern (Non-HVHZ only) NAILS Nailing` .......-............- Area. ---.....------------------------------ - _...... ........ 5-118" Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed(V,,,t): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed(V-d): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgate new construction; Min.7/16 in.OSB existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZONE COMMON BOND EXPOSURE 5-5/8" 12-3/8" - - 12-1/2"-- Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE COMMON AVIBOND 6-1/8" EXPOSURE 5-5/8" 1—►I �r-1/2' T ?-1/2"-►h- ?�8"-�7-1�°2"�-?-112"� It-i" Figure 4. Heritage®&Heritage®Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREK TAMKO BUILDING PRODUCTS '" Asphalt Shingles 1 S LLC TECHNICAL SERVICES,, NAIL ZONE/ ASTENERS;� COMMON BOND 8-1/8" FT RE 5 518" Figure 5. Heritage®Woodgate 6 Nail Pattern -►I1"il"it--12-1/2" �� ��12-1/2" �i?'il'��- j I ® Common Bond ' FASTENERS i 1i _7 39-3/8° Figure 6. Heritage®,Heritage®Premium,&Heritage®Woodgate Alternate 6 Nail Pattern PAINT LINE 7-718" -- ------- --------------------------_—-- -- – -- NAIL ZONE 6-1I8" EDGE OF COMMON BOND EXPOSURE 5-5/9, ACCEPTABLE FASTENER LOCATION DO NOT FASTEN ALONG EDGE OF ---------- ----- -- COMMON BOND PREFERRED FASTE NE R LOCATION Figure 7. Heritage®(Tuscaloosa) Expanded Nail Zone Nail pafterns from Figures 3,4,and 6 may be placed in the nall zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Premium Basic Wind Speed(V,„): Max. 194 mph (Frederick) Basic Wind Speed(V,,d): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BOND 5'12" [EXPOSURE 5" 12" —►�1- 11"---►{ 1 Figure 8. Heritage®Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS /COMMON BOND 51/211 EXPOSURE 5" Figure 9. Heritage®Premium (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Woodgate Basic Wind Speed(V,it): Max. 194 mph (Frederick) Basic Wind Speed(V.,sd): Max. 150 mph Deck(Non-HVHZ): In accordance with FBC requirements, Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BAND T- /T EXPOSURE Y 1'L- 11" --►�--.12-3/8"—►�— 11" —� k-1" Figure 10. Heritage®Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ COMMON BOND * FASTENERS Joe1 5.1/2 EXPOSURE 5" 1"—►I � 9-112"�►�4.3'�9-318"—►�3'+►�I.9-1/2"� �1" Figure 11. Heritage®Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Vintage® Basic Wind Speed(V„n): Max.194 mph (Phillipsburg) Basic Wind Speed(V.a): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Undedayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern'detailed below. 40, V Alan, rxposuR T7 g ^ Z Nalch Fxeenas — — — — — — — — — Ofq 17-1R" 5" FX PW R 41 A•-�---41M` 41/6' --41M• _t _t Figure 12. Heritage®Vintage® 5 Nail Pattern(non-HVHZ only) 4W Nord+ it -1 NN — � — — — lie - - - - - - - - - - 17-1�2` s Figure 13. Heritage®Vintage® 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.