HomeMy WebLinkAboutEngineering CLIENT INFORMATION PROJECT INFORMATION SPECICY DMEMNG
CONSULTANTS,Int
FLORIDA HOME IMPROVEMENTS BOWKER RESIDENCE 602283 {t�MEa1ERZ 150 +per AW
3044 SW 42nd STREET 5307 BUCHANAN DR. SEAC+•FL 33425
FORT LAUDERDALE, FL 33312 FORT PIERCE, FL 34982 W
BEAM
INSPECTOR NOTE: FL�Hans -P�
STRUCTURE WAS DESIGNED BASED ON THE INSPECTOR NOTE cul 4��
REPAIRS ARE OF A LEVEL 1 ALTERATION IN 2x4 ALUMINUM TUBE DETAIL
FBC 2017, AND 6I->u 410-5X10E
ASCE 7-10, 170 MPH (3 SEC), EXP. C. ACCORDANCE WITH OF THE EXISTING FOR NEW FO N3 AND SIDELR5
E �4 SBI-752Y-354x FAX
RISK CAT. 2. BUILDINGNG C CODE.
NOTES
EXISTING WOOD 1. TAPCONS SHALL BE ULTRACON BY ELCO ( 1 )4"MIN..EMBEDMENT, 2 14" MIN. EDGE DIST.)
STRUCTURE 2. ALUMINUM SHALL BE 6063-T6 MIN.
3. ALL FASTENERS SHALL BE GALVANIZED MIN, UNO.
4. WATERPROOFING, BY OTHERS.
5. OPENING SIZE AND STRUCTURE LOADING DOES NOT CHANGE
1
NEW 2x4 " 6063-T6 ALUMINUM TUBE 6. PROVIDE BARRIER BETWEEN ALUMINUM AND CONCRETE.
S1
ATTACHED W/CUPS TOP AND BTW. 7. FOLLOW MANUFACTURER INSTALLATION AND APPROVED NOA.
8. NOTIFY THIS ENGINEER OF ANY DISCREPANCIES.
EXISTING WOOD FILE COPY -�
/ STRUCTURE 0 0
/ 0 0
/ 204" 6063-T6
8° I ALUMINUM TUBE 2.
o
NEW DOOR,
BY OTHERS \ < FASTEN T0:
\
\ 0 0 'CONCRETE STRUCTURE W/ (4)>;"0 TAPCONS
NEW SIDELffEFASTEN CLIP TO ALUMINUM TUBE
\\ (1 J" MIN EMBEDMENT, 2 Ye" EDGE DISTANCE)
,
1 \ BY OTHERS W/ (3) #10 x 1" FH SCREWSSDE, -WOOD STRUCTURE W/ (4) #14 x 3"S.S.
WOOD SCREWS (1" EDGE DISTANCE)
51 \
1 2x4x1 4" ALUMINUM TUBE TO STRUCTURE CONNECTION .A
S1 M
SCALE:3" = 1'-0"
1,2
2 PARTIAL ELEVATION
SI SCALE:3/4"= 1'-0" RECEIVED C)?
MAR 13 X18 �J�,' RIDP.•'�t���c`'`
ST.Lucie County,Permitting
;S1 OF 1