HomeMy WebLinkAboutProduct Approval r
TIRII VIII 1 1 ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entipt Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certlicate oJAuthorizatlon#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 2 of 6
i
f i I
TRINITY ERD
Enti Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 ! 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 I 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 I 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 i 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
i UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL I 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,'R21,Minneapolis MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report„821,Mt.1Vernon,ilN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,11121,Baltimore,MD 10/21/2016
I UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,:R21,Dallas,TX 11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION: I,
4.1 Asphalt Shingles:
4.1.1 Marquise WeatherMaxe, Royal Sovereign® and Sentinel® are a fiberglass'reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude'"", Glenwood TM, Grand Canyon®, Grand'.Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield'", Monaco®, Sienna®, Timberline® American! Harvest®, Timberline®
I ArmorShieldTM II,Timberline® Natural Shadow®,Timberline HD®,Timberline®Cool,,Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShieldm Ridge Cap Shingles and Timbertexe Premium Ridge Cap Shingles are!fiberglass reinforced, hip
and ridge asphalt roof shingles.
i
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-1122
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
i
0
\J
.T,- 1N1 ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlockerT" Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatchTI Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchT" are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
use in all wind zones up to Vasd=150 mph (V,,It=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up
to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
IF
RINITY ERD
i 6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant,Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the 16AF current published instructions with
j a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5- Sealant
-77-(292 mm) 1° Sellante
(25 mm) (25 mm) Enduit d'etanch&6 i
12"
_mow (305 mm)
Nail
Clavo
6518,-7 518' Clouer
(168-194 mm)
i
! I
i
12°
(305 mm) j
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply.with GAF current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.'
5er�talrl
(25
Mir)) (Y203 milt) (25 mr.% {Solt nta
F-nduitWj tarichi`16
x 1
F N
i
it
(MMMI,
LlI ! '
12� _ I '
(W5 trrio I l i
I 6.4.3 Fasteners shall be in accordance with GAF published requirements, but 'not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
1
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22
6rdficate o/Authoriratlon#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
i
li
TRINI 7ryl ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:.
Contact the named QA entity for information on which plants produce products covered by Florida_ Rule 611320-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-RZ2
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6
9till!AMl_._
maw
MIAMI-DADE COUNTY
m
i PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) I 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION I Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Gardner Asphalt Corporation
4161 W.71 Avenue
Tampa,FL.33605
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Juri i diction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke thi's acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or materiall,fails to meet the requirements
of the applicable building code. i I
This product is approved as described herein,and has been designed to comply with the Florida'Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. j
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOAas an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
I this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade''County), Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-0707.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
i NOA: 17-0427.10
QMIAMMI.DMADEM= I
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 1 of 5
. I
i
ROOFING COMPONENT APPROVAL
Category: Roofing i
Sub-Category: Underlayment
Material: Asphalt I .
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BYiAPPL'ICANT:
Test Product
Product Dimensions Specification Description
APOC Tuff-Felt 26 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2
Manufacturing square#3d,.'
Location 91, 2
;United FGUR20 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2
Manufacturing square#30.
Location 91, 2
APOC Tuff-Felt 46 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location#1, 2
United FGUR10 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.,
Location#1, 2
United FGUR70 18"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
square#30.
Manufacturing q
Location#1, 2
� I
GatorSkin 42"x 285.8' rolls ASTM D 226 Type II Synthetic goof uriderlayment comprised
i Manufacturing ofjlayers of polyolefin film.
i Location 93
1 Weather-Armor CX-L 37.25"x 145' rolls ASTM D 226 Type II High strength hybrid underlayment
Manufacturing comprised of two layers of polyolefin and
Location#3 polyester.!synthetic fabric with a thin layer
of modified bitumen between the two
plies. i
I'
Weather-Armor SB-1 36"x 65' 8"rolls ASTM D 1970 Glass fiber;reinf6rced,polymer modified
Manufacturing asphalt,granulated self-adhered
Location#4 underlayment.
Weather-Armor HT3 39"x 65' 8"rolls ASTM D 1970 60-mils thick(nominally),self-adhering
Manufacturing membrane comp sed of elastic polymers,
Location#4 bitumen,glass reinforcements and a cross
laminated sheet surfacing.
NOA: 17-0427.10
ritathi•oaoecoutvrir I Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 2 of 5
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY,APPLICANT:
Test Product
Product Dimensions Specification Description
Weather-Armor FV 39"x 65' 8"rolls TAS 103 60-mils thick(nominally),self-adhering
Manufacturing
composed of elastic polymers,
Location#4: bitumen polyester and glass
1.
reinforcement.
i
MANUFACTURING LOCATIONS:
i
1. Tacoma,WA.
2. Eutaw,AL.
3. Hangzhou,China.
4. Springville,AL.
EVIDENCE SUBMITTED:
Test Agency Test Identifier. Test Name/Report Date
PRI Construction Materials GGI-100-02-01 ASTM;D 226; 06/22/12
Technologies GGI-101-02-01 ASTM D 226 06/22/12
GGI-132-02-01 ASTM D 226 04/28/15
GGI-176-02-01 ASTI'D 226 09/26/16
! GGI-178-02-01 ASTM16
1970 10/25/16
GGI-194-02-01 -ASTMD 1970 ' 08/04/17
GGI-196-02-01 ! TAS'"d 03 'i 08/08/17
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated ! I
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of APOC Tuff-Felt 26,United FGUR20,United FGUR70,GatorSkin,or
iWeather-Armor CX-L with a minimum 4"headlap and a 6"end lap mechanically fastened to
deck with approved nails and tin caps 6 inches o.c.minimum at all laps and three staggered
rows fastened at 12 inches o.c. minimum in the field of the roll.Nails shall be driven flush and
90 degrees to the roof deck.
I
! Surfacing: Shall be acceptable for use in approved asphaltic shingles;wood shakes l&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
i
I 1 i
i
i
i
' NOA: 17-0427.10
MIAMI•DAD;COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 3 of 5
I' I
i
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
i
Anchor Sheet: Minimum 2 plies or more of APOC Tuff-Felt 46,or United FGUR10 with a minimum 19"
headlap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6
inches o.c.minimum at all laps and three staggered rows fastened at 12 inches o.c.minimum in
the field of the roll.Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,)wood shakes,I&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
Deck Type 1: Wood,Non-insulated
Deck Description: 19/3z" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. I
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
I 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the side lap
edge and in a grid pattern spaced 12" o.c.in the field of the roll. i
Membrane: One or more plies of Weather-Armor SB-1,or Weather-Armor HT3 self adhering membrane
adhered to the anchor sheet with a minimum 3"headlap and 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles;wood shakes,&shingles,quarry
slate,and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes.
Deck Type 1: Wood,Non-insulated I
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 21626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor FT3 self-adhering membrane'adhered to the anchor sheet
with a minimum 3"headlap and 6"end lap.
I• I
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles, quarry
1.slate,metal roof,and mechanically fastened roof tile applications.'MustlComply with applicable
Roofing Application Standards and Building Codes.
i
t
I
I
i
I
MIAMI•DADE COUNTY NOA: 17-0427.10
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 4 of 5
• I
i
i
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufalcturer's,name or logo, city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material. I
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements; shall be in compliance
with applicable building code.
3. Weather-Armor SB-1, and Weather-Armor HT shall not be hot mop Iped; refer to manufacturer's published
literature for product compatibility.
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof are approved
Y P pP
1 under specific assembly Notice of Acceptance.
5. APOC-Tuff Felt 26,United FGUR20,APOC-Tuff Felt 46,United FGUR10,United FGUR70,GatorSkin,
Weather Armor CX-L, and Weather-Armor SB-1 listed herein shall not be left'exposed as a temporary roof
for longer than 30 days of application.
6. Weather-Armor HT3 and Weather-Armor FT3 listed herein shall not be left exposed as a temporary roof for
longer than 180 days of application.
7. Gardner Underlayments listed herein may be used with any approved roof'coveririg Notice of Acceptance
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire
testing results.
I
8. For fire classification of specific roof assemblies using Gardner Underlayments; listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product:
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA: 17-0427.10
MIAMI•DADE couNTY Expiration Date: 03/28/18
j Approval Date: 08/31/17
Page 5 of 5
I
i
i
12/14.2017 Florida Building Code Online
7177771-17707 77—
tt I. '
TT
L rim1a3 ' i
3a=. tq
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts j Publications I i FBC Staff I BCIS Site Map { Links Search'I
Florida
J."iy Product Approval
�f_'�" USER:Public User
+�-s
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail
I.
FL# FL10124-1120
Application Type Revision
nv
Cade Version 2017
Application Status Approved
Comments
cKF
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
a (800)766-3411
u p
mstieh@gaf.com
Authorized Signature Robert Nieminen
1 ° lindareith@trinityerd.com
Technical Representative William Broussard �I
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
TechnicalQuestionsGAF@gaf.com I
Quality Assurance Representative ;
�I
Address/Phone/Email
My
1 Category Roofing i
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from al Florida Registered Architect or a Licensed Florida
` a; Professional Engineer
EJ Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
- I
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/20/2018
Validated By John W.Knezevich,PE
Validation Checklist-;'Hardcopy'Received
t V
€CFz ^
Certificate of Independence FL10124 R20 COI 20171-01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 i 2016
ASTM D3462 2010
ASTM D7158 1 2011
TAS 107 1995
i
a * Equivalence of Product Standards
3 Certified By
https:/Avww.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BooyLwXhmdCmfpylEOlvyCA%3d%3d 1/2
i
I,
I
V
12/14/2017 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option
PP D
41 Date Submitted 09/20/2017
Date Validated 09/27/2017
Date Pending FBC Approval 09/28/2017
Date Approved 12/12/2017
Suminary of Pioducts
FL# Model,Numberor Name: '" Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R20 II 2017 09 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shingles FL10124-R20.odf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt
Shingles FL10124-R20.pdf
x Created by Independent Third Party:Yes
W
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
_ Product Approval Accepts:
Credit Card a
.Safe
}
hftps://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOlvyCAg/o3dg/gad 2/2
EXTERIOR RESEARCH&DESIGN,LLC.
:Certificate of Authorization#9503
C 353 CHRISTIAN STREET,UNIT#13
TRINITY ERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
GAF i, Evaluation Report 01506.01.08-1122
1 Campus Drive �' II ' FL10124-R20
Parsippany,NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6U'Edition '(2017 ).Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/11905.2.6.1. I'
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that irelate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreementito notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Tri n1ityI ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity;)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be°done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building,Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
ut,tttrrr,,., —
�9-:S,n���r•p�- f
Robert J.M.Nieminen P.E.
The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 tom` P.E.on 09/20/2017.This does not serve as an electronically signed
document. !
CERTIFICATION OF INDEPENDENCE:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial)interests in any company manufacturing or
distributing products it evaluates. I i
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing'or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other ehtity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are„in any I ay,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I ,
I '
I
j
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
11905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1122
Certificate ofAuthorhation#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 2 of 6
i
t I
I
i
i
I TRINITY ERD
Enti Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CA55908 I, 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 I 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 I; 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 I I 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 I 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 i 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 I'! 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 i 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 ! 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 !; 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
C UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/2016
I UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,'R21,Mt.lVernon„IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,,R21,Baltimore,MD 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA' 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles.
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® Il, Fortitudelm, GlenwoodTTM, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShieldT", Monaco®, Sienna®, Timberline® American, Harvest®, Timberline®
ArmorShieldT"' II,Timberline® Natural Shadow®,Timberline HD®,Timberline®Cool'Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingle's.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap, Shingles, Seal-A-Ridge®
ArmorShieldTm Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,I.I.C. i Evaluation Report 01506.01.08-11122
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles I Revision 22:09/20/2017
Page 3 of 6
I
i
TRINITY ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlockerTM' Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatch'"I Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchl are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
use in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up
to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
X� TRINITY J ERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the'GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle Pend nominal 0.25-inch diameter
beads of Henkel"Loctite PL S3O Roof&Flashing Sealant".
11.5 Sealant
1" (292 mm) 1/MoEnduit
Sellante j
(25 mm) (25 d'etancheite
12"
Nail
(305 mm)
,
Clavo
6 518'-7518- Clouer
(168-194 mm)
12" �I
(305 mm)` i
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and'.beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant;
1�( 92 mr i} 1` gllOntO i
(2itarrnp (25rnri r=rzduitdhbanchiM6
Nail
' { 'o 12' !,
mut at 05 arrn)
4
(229 mm)
I '
(375 Two)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but', not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
f,
i '
I
I.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22
Cer0 icate ofAuthori:atlon 119503 6EDITION(2017)FBC NON-HVH2 EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
rTRINI-ry ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
U L LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL30124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6
HTAM
- MIAMI-DADE COUNTY
M
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) I 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidaae.eov/eeonomv
Gardner Asphalt Corporation
4161 W.711 Avenue j
Tampa,FL.33605
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-":Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted here''in.
li
RENEWAL of this NOA shall be considered after a renewal application has been filed'and there has been no change
in the applicable building code negatively affecting the performance of this product. `f
TERMINATION of this NOA will occur after the expiration date or if there has been a!revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA!as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade:County',,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA isl'displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufa I'turer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-0707.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA: 17-0427.10
M IAMI-DADE coUNTY I Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 1 of 5
I
i
I
ROOFING COMPONENT APPROVAL i
Category: Roofing j
Sub-Category: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY,APPLICANT:
Test Product
Product Dimensions Specification I Description
APOC Tuff-Felt 26 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2
Manufacturing sq are#4
Location#1, 2
I,
United FGUR20 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2
Manufacturing square#36:
Location 91, 2
APOC Tuff-Felt 46 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
i Manufacturing square#15
Location 91; 2 j
United FGUR10 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing
square#15.
I I,
Location#1, 2
United FGUR70 18"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
Manufacturing square#30.
Location#1, 2
GatorSkin 42"x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing of layers of polyolefin film.
Location#3
fl
Weather-Armor CX-L 37.25"x 145' rolls ASTM D 226 Type II High strength hybrid underlayment
Manufacturing comprised;of two layers of polyolefin and
Location#3 polyester,synthetic fabric with a thin layer
of modified bitumen between the two
plies.
Weather-Armor SB-1 36"x 65' 8"rolls ASTM D 1970 Glass fiber;reinforced, polymer modified
Manufacturing asphalt,granulated self-adhered
Location#4 underlayment.
Weather-Armor HT1 39"x 65' 8"rolls ASTM D 1970 60-mils t I ick(nominally),self-adhering
Manufacturing membrane composed of elastic polymers,
Location#4 bitumen,glass reinforcements and a cross
laminated'sheet surfacing.
NOA: 17-0427.10
MIAMI•DADE COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 2 of 5
I I' ,
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY.APPLICANT:
Test Product
Product Dimensions Specification Description
Weather-Armor FT3 39"x 65' 8"rolls TAS 103 60'mils thick(nominally),self-adhering
Manufacturing m imbranecomposed of elastic polymers,
Location 94, bitumen polyester and glass
reinforcement.
MANUFACTURING LOCATIONS: I!
1. Tacoma,WA.
2. Eutaw,AL.
3. Hangzhou,China.
4. Springville,AL. R'
I i '
EVIDENCE SUBMITTED: r
Test Agency Test Identifier. Test Name/Report Date
PRI Construction Materials GGI-100-02-01 j.ASTM,D 226 06/22/12
Technologies GGI-101-02-01 AST4D 226 06/22/12
GGI-132-02-01 ASTMD 226 04/28/15
GGI-176-02-01 ASTMD 226 09/26/16
GGI-178-02-01 I,ASTMD 1970 10/25/16
GGI-194-02-01 ;ASTN6 1970 08/04/17
GGI-196-02-01 TAS!1:103 08/08/17
l ,
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32° or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of APOC Tuff-Felt 26,United FGUR20,United FGUR70, GatorSkin,or
Weather-Armor CX-L with a minimum 4"headlap and a�6"end lap mechanically fastened to
I deck with approved nails and tin caps 6 inches o.c.minimum at all laps and three staggered
rows fastened at 12 inches o.c. minimum in the field of the roll.Nails shall be driven flush and
90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles;;wood shakes;°&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
i
NOA: 17-0427.10
MIAMI•DADE COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 3 of 5
I"
e
;
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank !4
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: Minimum 2 plies or more of APOC Tuff-Felt 46,or United FGUR10 with a minimum 19"
headlap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6
1.
inches o.c. minimum at all laps and three staggered rows fastened1at 12 inches o.c.minimum in
the field of the roll.Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,�woods hakes,;;&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and BuildingCodes.
! E,
Deck Type 1: Wood,Non-insulated
l
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 witli;a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails andlin caps 6 o.c.at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor SB-1,or Weather-Armor HT3 self-.adhering membrane
! adhered to the anchor sheet with a minimum 3"headlap and 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,!&shingles,quarry
slate, and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes.
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
i
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered. "
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 witfta minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and�tin caps 6" o.c.at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of tie roll. ;
Membrane: One or more plies of Weather-Armor FIT self-adhering rriembra`e''adheed to the anchor sheet
with a minimum 3"headlap and 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles;wood shakesjl&shingles,quarry
jslate,metal roof, and mechanically fastened roof tile applications:wMust Comply with applicable
Roofing Application Standards and Building Codes, j' f
f
k
I
i
f
NOA: 17-0427.10
QMIAMI-DADE COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 4 of 5
k
k
� kr
li
1
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below. [
MIAMI•DADE COUNTY
i
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Oficial or applicable building code in order to properly evaluate
the installation of this material.
�i
r
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building code.
3. Weather-Armor SB-1, and Weather-Armor HT1 shall not be hot mopped; refer to manufacturer's published
literature for product compatibility. j
4. Gardner Underlayments listed herein are components used in roof assemblies: Roof assemblies are approved
under specific assembly Notice of Acceptance. �' k
II,
5. APOC-Tuff Felt 26,United FGUR20,APOC-Tuff Felt 46,United FGUR10,United FGUR70,GatorSkin,
Weather Armor CX-L,and Weather-Armor SB-1 listed herein shall not be leftexposed as a temporary roof
for longer than 30 days of application.
6. Weather-Armor HT1 and Weather-Armor FT listed herein shall not be left exposed as a temporary roof for
longer than 180 days of application. k'
7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami-Dade County Product Control DIepartment for:approval provided that
appropriate documentation is provided to detail compatibility of the products!;wind uplift resistance, and fire
testing results. i
8. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.l
9. All products listed herein shall have a quality assurance audit in accordance;with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
i
I ,
ii
NOA: 17-0427.10
MIAMI•DADE COUNTY I Expiration Date: 03/28/18
Approval Date: 08/31/17
' Page 5 of 5
I
I;
I
I I�