HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
l` (�
fill
F
BCIS Home I Log In User Registration Hot Topics I-Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links •Search
Ronda
r Product Approval ^:
Ig USER:Public User I
y I
Product Aooroval Menu>Product or ArolicaticTn Search>Anollcation List>Application Detail
• FL# FL10124-R20
Application Type Revision
' Code Version 2017
Application Status Approved
Comments
Archived — ❑
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf.com
I I ,
Authorized Signature Robert Nieminen
lindareith@trinityerd.com j I
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
j TechnicalQuestionsGAF@gaf.com
I Quality Assurance Representative I
Address/Phone/Email
I
Category Roofing
Subcategory Asphalt Shingles
i
Compliance Method Evaluation Report from a Florida Rel istered Architect or a Licensed
Florida Professional Engineer
j ❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC ,
Quality Assurance Contract Expiration Date 10/20/2018 j
Validated By John W. Knezevich,PE
Wj Validation Checklist-HardcopyReceived' .
I I ,
Certificate of Independence FL10124 R20 COI 2017 01 COI Ni min nI odf
i I ,
Referenced Standard and Year(of Standard) Standard Vear
ASTM D1970 2015
ASTM D3161
� 2016
ASTM D3462 2010
ASTM D7158 I 2011
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
' I
I
I
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=WGEVXQ;WtDquracBeVCbdM... 2/8/2018
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 09/20/2017
Date Validated 09/27/2017
Date Pending FBC Approval 09/28/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinfo'r'ced 34A,'Iaminated,5-tab and hip/ridge
asphalt shingles'l I
I
Limits of Use Installation Initructions'
Approved for use in HVHZ;No FL10124 R20 ft 2017 69 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shinales FL10124-R20.pdf-
Impact Resistant:N/A Verified By: Robert Nierninbri PE-59166
Design Pressure:N/A Created by Independent pendent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports I,
FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt
Shinoles FL10124-R20.Ddf, I
Created by Indd endent Tifiird Party:Yes
..-ck-1 .F_1
Contact Us 2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-18,2
The State of Florida is an AA/EEO employer.Copyriobt 2007-2013 State of Florida.::Privacy Statement:: -essibility Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have ahy questions!please contact 850.4B7.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.Howeve',email addresges are p6blic record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts,
ME a GiW 19 Mtl
Credit Card
Safe
fi
i .
https://www.floridabuilding.org/pr/pr—api)—dtl.aspx?param=wGEVXQwtDquracBeVCbdm... 2/8/2018
i
o � �
EkTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINITY EI\® 353 CHRISTIAN STREET,UNIT QOI OXFORD,CT 06478478
(203)262-9245
EVALUATION REPORT
GAF I Evaluation Report 01506.01.08-1122
1 Campus Drive FL10124-R20
Parsippany,NJ 07054 Date ofl Issuance:01/03/2008
(800)766-3411 I Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regi lations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
11 1
products described herein have been evaluated for compliance with the 6 Edition (2017) ;Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the nal ed products) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement►to notify Robert Nieminen, P.E.if the
product'changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it,shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Biuilding Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Gt
Robert J.M. Nieminen,P.E. ; s��� g�;�, i
1�J1i�������i�s+` The facsimile seal appearing'was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 4�'' P.E.on 09/20/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financials interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. I
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are !in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
1 I
= '
-JTRINITYIERD
ROOFING S.mms EVALUATION:�
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF, have derno'nstrated compliance with the
. d'e, Residential Volume
no/mw/nm ,ccvm� v. "= ° Edition= '~�'' ...�� -__-,~ -__- --- _.lori6 _ ,
Requirementsthrough testing in accordance with the following Standards. Compliance is subject to the Installation
|
|
2. SrAmo�aDs
i '----' |
' Section Property | | Year
1507.2.4/1507.1.1, Properties ASTM D1970
/ \ zu��
n9052.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 | ZOIO
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D715u | zozz
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 | 1995
'
3. REFERENCES: � (
Examination Reference | Date
E�(P0w��� b����m�|�m 3�����|m �� |n 01/13/2012
PRI(T5TsU78) Physical Properties GAF-025-02-01 03/27/2002
l
PRI ASTM GA�O59'O2'Oz ` 0�0�2oD4
' /
� GAF-080-02-01 | 05/25/2005PH(�ST5870 ASTM D3462
PRI(TSTS87O) Physical Properties GxF-32402-01 � 12/01/2011
PRI(T5T587D) Wind Driven Rain GAF-407-02'01 / 01/21/2013
�
ASTM 93NK6295 ` 11/29/1993
U���Tz74O) �
| UL(TSTz74O) ASTM D3462 99NK43835 ! � � 01/12/2000
UL(TST1740) TAS107 94NK9632 | 03/29/2000
ULU3Tz74O| ASTM D]46z 01NK06632 \ . 02Y02/2001
> ASTM o318�l��1O7 ozN�92z6 ' U�2�2VO1
UL � .
\ ~''~---` ��--' — --
A�lM D3161 O1No37122 z2/z�200z
u����4�
( UL(T6Tz74O) ASTM o3462 01NK37122 ' 12/19/2001
ASTM O2Nnz298V � 04/10/2002Ui�5T17wN ! �
UL(TJrz74O) ASTM D3161,TAS 1O7 02NK30871 09/09/2002
| uL(TSTz74O) ASTM D3161 03[A5367 03/11/2003
' UL(TST 1740) ASTM D3462 03NK26444 ! 10/17/2003
ULUSr174V> ASTM D346z 04NK13850 | ' 0607/2004
| �
ASTM 04NK1�8S0 | 06/23/2004U��5Tz7�� i
UL(TSTz740) ASTM D3161 04NK30546 . 03/10/2005
| UL(TST174O) ASTM D34oz 0*0K22009 05/06/2005
UL(TSTz740) ASTM D3161 04NK22009 05/09/2005
> UL(T5Tz740) ASTM D346I 05NK27924 0Y10/2006
/
UL(TST174O) ASTM D316z 05NK27924 � 02/11/2006
| UL(TSTz74o) ASTM n3Inz'D34oa 06CA18077 | 06/05/2006
| UL(TsT17w0) ASTMo]161,o34az o6Cx18074 ! 06/16/2006
UL(TSTz740) ASTM oS1sz,oa4sz 06CA35251 ! � . 10/18/2006
UL(T3T174O) ASTM D346u 06{A31603 i 12/01/2006
' UL(TSTz740 A5TMD3161,D3462 06Cx41095 12/27/2006
| UL(T8'1740) ASTM D3161 07NK05228 i / 03/13/2007
| UL(TSTzJ4N ASTM o3161 06Cx31611 | 04/04/2007
UL(TSTz74O) ASTM D3161 06Cx61148 i | 04/09/2007
UL(TB'174o) ASTM o3161,D3462 07CA31742 | 11/08/2007
UL(T8'z74U) ASTNDs161,[nz58,D346z ODCA06100 ' 03/13/2008
i .
��x�c�n�
sm,wmn�ma�hand nemgn U.C. am�� Report� � . n
m^���ww"�"� a
" " #9503 �=Eomom(ao17)pocmom'ovxZomuuArmm ! pu0124-m0
GAF Asphalt Roof Shingles Revision 22:09/20/2017
/
Page 2m6
| .
|
i I
I
►'� ER®
RINITY(
Enti Examination Reference I Date
UL(TST 1740) ASTM D3161,D3462 07CA55908 I 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 ! 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 I 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 ! 10/29/2010
i UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 I 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 I 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 i 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 I 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 I 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,!R21,Mobile,AL i 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,121,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,!121,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,121,Michigan Cty,IN 11/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,iR21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,-R21,Minneapolis,MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.IVernon,IIN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,11121,Baltimore,MD 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX ; 11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,'Ennis
,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude'"", GlenwoodTm. Grand Canyon®! Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShieldTM, Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShieldTM II,Timberline® Natural Shadow®,Timberline HD®,Timberline® Cool Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShieldTM Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are;fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION I' FL10124-RZO
GAF Asphalt Roof ShinglesI Revision 22:09/20/2017
Page 3 of 6
i
i
i
i
)0! ,'RR'1 I 1 1 I ER®
4.3 Accessory Starter Strips:
4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker- Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
i
4.3.3 StarterMatchTM Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchl are instal[led as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
i
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Niem�nen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for' that p uI rpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. ;
5.3 Fire Classification is not part of this Evaluation Report; refer to' current;Approved Roofing Materials
Directory for fire ratings of this product.
5_4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in acct l dance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for
use in all wind zones u to V 150 mph V ' '
P asd= p ( „it=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in iaccordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up
to Va,d=150 mph(V,,it=194 mph). Refer to Section 6 for installation',requirements to meet this wind rating.
I
j 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, asl defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualifieddesigni professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment: I `
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.31
i
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF Icurrentlpublished instructions.
6.3 Asphalt Shingles:
1 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia!iR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle. j
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but riot less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, ipe, cial methods of fastening are
required. Contact the GAF for details. i
Exterior Research and Design,U.C. I Evaluation Report 01506.01.08-1122
Certificate Of Authorization 119503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION I FL10124-R20
GAF Asphalt Roof Shingles ! Revision 22:09/20/2017
Page 4 of 6
i ,
I
_ 1
I
,• i i I.
F T11�11TY(ER®
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the,IGAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5' Sealant
1• (292 mm) 1° Sellante
(25 MM) (25 mm) Enduit d'etancheite
I
k � i
Nail (30 mm)
Clavo
I
6 5/8'-7 5/8' Clouer
(168-194mm)
j
i
(305 mm)
1
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply';with GAF current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, pier shingle and beads of Sonneborn NP3
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant:
(292 rnrn} r Sealaltl
1' ellanta
(25 tni>i) q25 mm Rnduit WiitanchiW j
;.
Nab
rw 5p'
,t�'puer
(229 mm•
i
I
{305 nun)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
I
� I I
I
1
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-1122
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION j FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
JERD
TRINITY
7. LABELING:
7.1 Labelifig shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the!required,classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in orderlto properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
IJ I1
Exterior Research and Design,LLC. I Evaluation Report 01506.01.08-R22
Certificate ofAutharization#9503 EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6