HomeMy WebLinkAboutProduct Approval FILE COFY RECEIVED
MAR 14 2018 MIAMI-DADE COUNTY
IwllAMl' &F ODUCT CONTROL SECTION
51', Lucio County, Permitting
Y-- - 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®American Harvest®,and
FortitudeTM Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0811.11
MIAMFDADE C3 Expiration Date:02/21/22
Approval Date:02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Cateeory: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American®Harvest®,and
FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HD® 13 '/a'x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow® roof shingle,with a laminate profile
Manufacturing
Locations#1,2,3,4,5,6,7
GAF Timberline®American 13 '/4"x 393/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest® roof shingle,with a laminate profile
Manufacturing
Locations#2,4,5,6
GAF Fortitude7m 13 '/4"x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,4
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
NOA No.: 16-0811.11
MIAMI•DAD;COUNTY Expiration Date:02/21/22
RIJUN1431
Approval Date: 02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Aeency Test Identifier Test Name/Revort Date
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 I ICA48924 10/24/11
Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
Mii•oaoe couNrt� Expiration Date:02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with Detail'B',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAWDADE COUNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
htwt7NoaneCOUrrrY Expiration Date:02/21/22
Approval Date: 02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
DECK
FULL
5th
17" OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1st
NOA No.: 16-0811.11
MIAMI-owDe coUNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/8"
(1 m)
14-1/2"-17-1/2" 14-1/2"-17-12"
(368-445mm) (368-445mm)
6-12"-9-1/2" {� 6-12"-9-12" ail guide line
I (,es-24i—)
(146mm-159mm)
53,4".6 1,4-
(337m ) + ♦_
VT2 1�" from bottom of shingle
9
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
'required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6"(152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
NOA No.: 16-0811.11
htwt�ND►ne coup Expiration Date:02/21/22
Approval Date:02/09/17
Page 6 of 6
RECEIVED
MAR 14 2018
MIAMIDADE
ST. Lucie County, PerMIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11$05 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DMSION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/economy
GAF
1 Campus Drive
Parsipanny,NJ 07054 FILE COPY
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 16-1213.04 and consists of pages 1 through 10.
The submitted documentation was reviewed by Hamley Pacheco,P.E.
MIAMI-DADE CNOA No.: 18-0119.15
OON TY
�, Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 1 of 10
ROOFING COMPONENT APPROVAL
Category: hoofing
Sub-Category: Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
WeatherWatch®Mineral 36"x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Surfaced Leak Barrier 36"x 66.7' rolls bituminous sheet material for use as a leak barrier
Manufacturing underlayment in sloped roof assemblies.
Location#1,9 Designed as an ice&rain shield.
StormGuard®Film 36"x 66.7' rolls ASTM D 1970 Modified, fiberglass reinforced,bituminous sheet
Surfaced Leak Barrier material for use as a high temperature leak barrier
Manufacturing underlayment in sloped roof assemblies.
Location#1,9 Designed as an ice&rain shield.
LibertyTM SBS Self- 39-'/8"x 66' rolls ASTM D 1970 Self-adhering SBS roof membrane.
Adhering Base/Ply Sheet ASTM D4601
Manufacturing Type H
Location#1,9
Deck-Armor'Premium 54"x 222' rolls ASTM D 226 A UV-stabilized polypropylene breathable
Breathable Roof Deck 48"x 100' rolls Type H underlayment. To be used for roof deck
Protection protection as an underlayment in sloped roof
Manufacturing assemblies.
Location#2
Tiger Paw"Roof Deck 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable
Protection 48"x 100' rolls Type II underlayment.To be used for roof deck protection
Manufacturing as an underlayment in sloped roof assemblies.
Location#3,5,6
FeltBuster®High-Traction 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable
Synthetic Roofing Felt Type I underlayment.To be used for roof deck protection
Manufacturing as an underlayment in sloped roof assemblies.
Location#7,8
Shingle-Mate®Roof Deck 36"x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment. To
Protection Type I be used for roof deck protection as an
Manufacturing underlayment in sloped roof assemblies.
Location#4
NOA No.: 18-0119.15
MIAMI•DAD,CouNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 2 of 10
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
LibertyTm SA Glass Cap 39 3/8"x 34' rolls ASTM D 1970 Granular surfaced modified,fiberglass reinforced,
Sheet ASTM D 6163 self-adhering SBS roof membrane.
Manufacturing ASTM D 7530
Location#9
GAFGLAS®Ply 4 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlt
Manufacturing (1 meter)Wide Type IV coating.
Location#9, 10
GAFGLAS®FlexPlyTM 6 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlt
Manufacturing (1 meter)Wide Type VI coating.
Location#9,10
MANUFACTURING LOCATION:
1.Mt.Vernon,IN
2.North Bay,Ontario
3.Mission,British Columbia
4.Pryor,OK
5.Qingdao,China
6.Charleston, SC
7.Spartanburg, SC
8.Dadra,India
9.Savannah,GA
10.Mobile,AL
NOA No.: 18-0119.15
MIAMI•DADE COUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 3 of 10
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Renort Date
Intertek Testing Services NA Ltd. 3077464-01 ASTM D 1970 08/23/06
3090131 Wind Uplift and Self Sealability 08/23/06
100258583COQ-OIOA ASTM D 226 Type H 01/08/11
100673818COQ-003 ASTM D 226 Type 11 06/13/13
10157289000Q-005 ASTM D 226 Type II 04/17/14
F8549.02-106-18 ASTM D 226 Type I 11/08/16
PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07
Technologies,LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06
GAF-238-02-01 ASTM D 1970 03/03/10
GAF-323-02-01 ASTM D 1970 11/30/11
GAF-324-02-01 ASTM D 1970 12/01/11
GAF-325-02-01 ASTM D 1970 12/01/11
GAF-326-02-01 ASTM D 1970 11/30/11
GAF-275-02-01 ASTM D 1970 11/11/10
GAF-344-02-01 ASTM D 1970 04/23/12
GAF-339-02-01 ASTM D 226 Type 1 03/14/12
ELK-311-02-01 ASTM D 1970 09/11/07
GAF-518-02-01 ASTM D 226 Type 1 06/04/14
GAF-818-02-01 ASTM D 4533 12/06/17
GAF-829-02-01 ASTM D 226 Type H 01/15/18
GAF-314-02-01 ASTM D 2178 07/21/11
GAF-315-02-01 ASTM D 2178 07/21/11
Trinity-ERD GAF-SC13285.03.17-1 ASTM D 1970 03/08/17
GAF-SC13285.03.17-3 ASTM D 1970 03/01/17
GAF-SC13285.03.17-4 ASTM D 1970 03/01/17
GAF-SC13285.02.17-2 ASTM D 4601 Type fI 02/08/17
GAF-SC9700.08-15-R1 ASTM D 2178 09/09/15
GAF-SC12915.12.17-R1 ASTM D 1970 12/11/17
GAF-SC12915.12.17-R1 ASTM D 6163 12/11/17
GAF-SC12915.12.17-R1 ASTM D 7530 12/11/17
NOA No.: 18-0119.15
MIAMI•DADE COUNTY Expiration Date: 02/22/23
...6 -��
Approval Date: 02/22/18
Page 4 of 10
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type Il,Deck-Armoil Premium Breathable Roof Deck Protection,FeltBuster®
High-Traction Synthetic Roofing Felt,or Tiger PawTM Roof Deck Protection with a minimum 4"
side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film
Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet,or LibertyTM SBS Self-Adhering
Base/Ply Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of
membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the
release membrane as the membrane is applied. Vertical strapping of the roof with
WeatherWatch®Mineral Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier is
acceptable.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
MIAMI•DAD,COUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 5 of 10
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAFGLAS®Ply 4,GAFGLAS®FlexPlyTm 6,Shingle-Mate®Roof Deck
Protection,Deck-Armoil Premium Breathable Roof Deck Protection,FeltBuster®High-
Traction Synthetic Roofing Felt, or Tiger Pawl Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film
Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet,or LibertyTM SBS Self-Adhering
Base/Ply Sheet membrane mechanically fastened with a minimum 3"side lap and a 6"end lap to
deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two
staggered rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
MIAMI OADE COUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 6 of 10
Deck Type 1: Wood,non-insulated
Deck Description: 19/32° or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered.
Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier, ,LibertyTM SBS
Barrier: Self-Adhering Base/Ply Sheet,LibertyTM SA Glass Cap Sheet,or StormGuard®Film Surfaced
(Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base
sheet.Do not overlap end or side joints.All side and end laps should be butted firmly side by
side, flush with each other but not overlapped.Do not leave the WeatherWatch®Mineral
Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier membrane exposed for more
than 30 days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof-Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-ArmorTM Premium Breathable Roof Deck Protection,
FeltBuster®High-Traction Synthetic Roofing Felt, or Tiger Paw'Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c.at the laps and four staggered rows 12"o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
MIAWDADEcouNrYM Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 7 of 10
Deck Type 1: Wood,non-insulated
Deck Description: "/32"or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-Armoi'Premium Breathable Roof Deck Protection,
FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger Pawl Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6"o.c.at the laps and four staggered rows 12"o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard®Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Surfacing: Approved for Metal roofing, Slate,and Asphalt Shingle assemblies.
NOA No.: 18-0119.15
MIAMI-DACE COUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 8 of 10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck
Protection, Deck-Armor' Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic
Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch®
Mineral Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply
Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable
Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection
as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak
Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, LibertyTM SA
Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armoi'Premium Breathable Roof Deck Protection,
FeltBuster®High-Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request
may be made to the Authority Having Jurisdiction(AHJ) or the Miami-Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance,and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45° F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions.
NOA No.: 18-0119.15
MIAM-DADEcouNrY Expiration Date: 02/22/23
...V a�
Approval Date: 02/22/18
Page 9 of 10
LIMITATIONS:
10. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control
Approved"or the Miami-Dade County Product Control Seal as shown below.
MIAMI-DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 18-0119.15
MIAMI•DAD,COUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 10 of 10
RECEIVED
MAR 14 2018
MIAMI•DADE ,. ST. Lucie County, Permitting
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv
GAF --py
1 Campus Drive 0
Parsippany,NJ 07054 FILE C
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Cobra® Ridge RunnerTM Exhaust Vent for Roof Ridge
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises and renews NOA#14-1022.10 and consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 17-0822.06
MIAMFDAD;COUNTY Expiration Date: 11/01/22
Approval Date: 10/19/17
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material: Plastic
Minimum Slope: 2:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
GAF Cobra®Ridge 20' Length(Roll) TAS 100 Low profile attic ridge vent in roll form for
RunnerTM Exhaust 11.5"Width installation under ridge shingles.
Vent for Roof Ridge .7"Height
MANUFACTURING LOCATION
1. Cumming,GA.
EVIDENCE SUBMITTED
Test Auency/Identifier Name Report Date
Architectural Testing ASTM D 1929 D8532.01-106-18 07/10/14
ASTM D635 D8532.01-106-18 07/10/14
ASTM D 2843 D8532.01-106-18 07/10/14
Intertek/Architectural Testing ASTM G155 E2672.01-106-18 07/08/15
ASTM D638 E2672.01-106-18 07/08/15
PRI Construction Materials Technologies,Inc. TAS 100(A) GAF-783-02-01 08/01/17
NOA No.: 17-0822.06
MIAMFDAD;COUNTY Expiration Date: 11/01/22
Approval Date: 10/19/17
Page 2 of 4
APPROVED APPLICATIONS
Tradename: GAF Cobra®Ridge RunnerTM Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of ridge vent.
Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of
each side of ridge. Cut a 1 3/4"(no ridge board)or 31/4"(ridge board)maximum slot
along the apex of the roof by cutting 7/8" (no ridge board)or 15/8"(ridge board)on each
side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length
of ridge vent used.
Installation: Place,center and conform the end of a piece of ridge vent at each end of slots. Mark the
location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce
baffle alignment. Place vent sections centered over the slot using a chalk line. Place
nails at pre-marked locations on top of the vent.Nails shall be minimum 12 guage 1 3/4"
corrosion resistant ring shank roofing nails,a minimum 3/16"penetration into wood
substrate is required.
Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place,as per ridge cap
shingle manufacturer's installation instructions.Nails shall be minimum 12 gauge 1 3/4"
corrosion resistant ring shank roofing nails,a minimum 3/16"penetration into wood
substrate is required.
Ventilation Calculations: Refer to manufacturer's published literature.
LIMITATIONS:
1. Refer to applicable Building Code required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Ridge Vent shall not be installed on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo,city and state of manufacturing facility,and following statement: "Miami-Dade
County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below.
MIAMI-DADE COUNTY
��Fjjvsxjqlj
NOA No.: 17-0822.06
MIAWDADECOUNTY Expiration Date: 11/01/22
Approval Date: 10/19/17
Page 3 of 4
DETAIL A
W
i
i
i
i
i
2C'Length
M
1
w i
BOTTOM VIEW
TOP (VIEW
11.5"Wide 7"
END VIEW
END OF THIS ACCEPTANCE
MIAMFDADE COU NOA No.: 17-0822.06
� Expiration Date: 11/01/22
jl Approval Date: 10/19/17
Page 4 of 4