Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 �.. r . ' BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff i,BCIS Site Map Links Search a ! F[a;ida Product Approval R= V USER:Public User AF,�} .tSrn Product Approval Menu>Product or ADDlication Search>Application List>Application Detail �;o x FL# FL22513-R1 Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By f61 affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONo ON/A Product Approval Method Method 1 Option A https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46... 3/14/2018 Florida Building Code Online Page 2 of 3 Date Submitted 11/21/2017 Date Validated 11/21/2017 Date Pending FBC Approval Date Approved 11/26/2017 Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RI C CAC NI013747.0l.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure:+50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R1 II FL0212.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 R1 AE 514008.odf system is required. Door top rails stamped"HPC".See DWG- Created by Independent Third Party: Yes MA-FL0212 for details. 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 Rl C CAC NI013747.04.odf' Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other:Evaluated for use in locations adhering to the FL22513 R1 II FL0215.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed.3'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 R1 AE 514009.odf system not required.See DWG-MA-FL0215 for details. Created by Independent Third Party: Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 Rl C CAC NI013747.04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R1 II FL0215.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 R1 AE 514007.odf system not required on opaque panels,but Is required on Created by Independent Third Party: Yes glazed sidelites.See DWG-MA-FL0215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 Rl C CAC NI013747.04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 Rl II FL0215.odf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R1 AE 514007.odf system not required on opaque panels,but is required on Created by Independent Third Party:Yes glazed sidelites.See DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RS C CAC N1013747.06.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure:+40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 Rl II FL0217.0f Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46... 3/14/2018 Florida Building Code Online Page 3 of 3 When impact resistance is required,hurricane protective FL22513 R1 AE 514007.odf system is required. See DWG-MA-FL0217 for details. Created by Independent Third Party:Yes 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RI C CAC NI013747.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+70/-70 Installation Instructions Other:Evaluated for use in locations adhering to the FL22513 RS II FL0211.12df Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed.3'-0"x 6'-8"max nominal size. Evaluation Reports When Impact resistance is required,hurricane protective FL22513 R1 AE 514010.odf system not required.See DWG-MA-FL0211 for details. Created by Independent Third Party:Yes 22513.7 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sldelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R1 C CAC NI013747.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R1 II FL0211.odf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RI AE 514008.Ddf system not required on opaque panels,but is required on Created by Independent Third Party:Yes glazed sidelites. See DWG-MA-FL0211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R1 C CAC NI013747.03.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30%2021 Design Pressure:+50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RI II FL0214.pdf Florida Building Code,Including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 R1 AE 514008.Ddf system is required. See DWG-MA-FL0214 for details. Created by Independent Third Party: Yes Back Neat Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card. Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46... 3/14/2018 L•. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514010 434-688-0609 Date: 05/01/2017 rllomas Irlomasp e.com Test Report: N/A Product: Single door Tx 6'8"(Wood Frame) Scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/6 w/out gap: a. With threads present in shear plane Fastener type:410 wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyy= 80,000 psi side member:Douglas Fir-Larch(6=0.50) Main member:Spruce-Pine-Fir(G=0.42) Side member thickness: t,= 1.000 in Main member thickness: %= 1.500 in Side member dowel bearing strength: F.= 4,650 psi Main member dowel bearing strength: Fpm= 3,350 psi Side member dowel bearing length: I,= 1.000 in Main member dowel bearing length: 1m= 1.140 in Mode Im Mode I, Mode II Mode IIIA, Made III, Mode IV qm= 636.5 lbs/in qs= 884 lbs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.0014 P= 725.61 lbs P= 884 lbs B: 1.07 B: 0.57 B: 0.5 B: 0.000 KD= 2.400 KD= 2.400 C: -427.67 C: -253.62 C: -267.7 C: -93.6 Z.= 302 lbs Z,, 368 lbs P= 331 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs Ko= 2.400 P= 297 lbs P= 319 lbs P= 263 lbs Min.Design value: Z= 110 lbs Z= 138 lbs Ko= 2.400 KD= 2.400 Ko= 2.400 Duration Factor: CD= 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value(ZCD): Z'= 175 lbs/onchor Solid members w/6 w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: 9: 0.0000 in Root diameter: or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member:Douglas Fir-larch(6=0.50) Main member:Steel strap/clip Side member thickness: t,= 1.000 in Main member thickness: tm= 0.048 in Side member dowel bearing strength: Fu= 4,650 psi Main member dowel bearing strength: F_= 61,850 psi Side member dowel bearing length: 1,= 1.000 in Main member dowel bearing length: 1m= 1.140 in Mode I. Mode I, Mode II Mode III„ Mode III, Mode IV qm= 11752 lbs/in qs= 884lbs/in A: 0.0003 A: 0.00059 A: 0.00033 A: 0.0006 P= 13397 lbs P= 884 lbs at 1.07 B: 0.57 B: 0.5 B: 0.000 Ko= 2.400 KD= 2.400 C: -4038.9 C: -3864.9 C: -267.7 C: -93.6 4= 5582 lbs Z�= 368 lbs P= 2287 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs KD= 2.400 P= 2126 lbs P= 420 lbs P= 392 lbs Min.Design value: Z= 163 lbs Z= 953 lbs KD= 2.400 KD= 2.400 KD= 2.400 Duration Factor: Co= 1.6 Z= 886 lbs Z= 175 lbs Z= 163 lbs Allowable Design Value(ZCD): Z'= 262 lbs/anchor Fastener type: 1/4"ITW Tapcon N.O.A.16-1222.06 Substrate:Hollow block Minimum embedment: 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z= 202 lbs Edge distance: 2.00 in Tabulated shear design value: Z= 161 lbs Actual edge distance: 2.50 in Reduction factor: 0.85 Spacing: 4.00 in Tabulated shear design value: Z= 202 lbs Spacing: 2.00 in Tabulated shear design value: Z= 164 lbs \�N\��S R•� b , Actual spacing: 3.00 in Reduction factor: 0.91 C E c1 ♦. &-,e Allowable Design Value(Zfw +\ )• Z"= 155 lbs/anchor ` • • i r . Minimum anchor capacity: 155 lbs/anchor =*a5� • •=. - Note:Anchors with the least capacity is used for calculations to quality anchors with higher capacity. ♦ _,(L. . A'4-- TAT >p'- TAT OF- Anchor calculations,minimum required anchors 5-04 ♦ A(/ 7C 36.38 Design pressure: 85.0 psf //F•. O ROP' N•�+�\ jj Max. Anchor IV / �7� -� Area Load Ind. z�'. ONAttL. (ft) Al Zone z O.C. Cap. Load Result A2YA2 79.25 (lbs) (in) (in) (lbs) Qty (lbs) AI 2.3 195 N/A N/A 155 2 98 OK Luis R. Lomas P.E. A7 _F AZ 7.7 656 6.00 18.00 155 5 131 OK FL No.: 62514 1 of 2 5/2/2017 L-. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514010 434-688-0609 Date: 05/01/2017 rl l o m a s Ca)I f I0 rn a s p e.co rn Anchor Locations: 36.36 18.19 6.00 TYP. 6.00 T'P. 6.00 13.45 MAX.O.C. 79.25 6.00 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16"TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MINIMUM B.CONCRETE:MNIMUM COMPRESS E STRENGTH OF 2,000 PSI. \`t�`�Cj C.MASONRY:HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. �\ J • G E ool •�!Q D.METAL STRUCTURE:STEEL 18GA(.048")FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI • .052"THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE *� 0rrJ� • DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. TAT OF " jS/0NAL1E �`�`. tiu,1 Luis R. Lomas P.E. FL No.: 62514 2 of 2 5/2/2017 11 1 1 MASONITC. 149°MAX. OVERALL FRAME WIDTH 0 00 U p0 27" MAX 36.375" MAX. Q WOOD-EDGE STEEL DOOR UNIT D.L.O. PANEL WIDTH 37.5" MAX.F_ Q p 6'-B"DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH p J U) GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING T ® ® ® ® W O Q THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM = DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. LL j U 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON m O OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), -A HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE _ PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED W MO ON PANELS WITH NON-IMPACT GLASS. i 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 a AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: ' TEST DESCRIPTION DESIGNATION LITE FRAME � y SELF IGNITION TEMP ASTM D1929 842 'F > 650 'F RATE OF BURNING ASTM D635 1.28 IN MIN W SMOKE DENSITY ASTMto D2843 70.27. TENSILE STRENGTH- ASTM D638 1.8% DIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING g .. 4500 HOURS XENON ARC METHOD 1 0 0 DOUBLE DOOR UNIT W/SIDELITES a a Addendum to NO } m Ced�rcafionNo.�. 013 y Reviewed By. Date Review 1313 ® 13 1313 1313 13M 1313 013 1313 0_ rn -no ! Uj Lin I L SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNfT SINGLE DOOR UNIT SINGLE DOOR UNIT W/SIDELITES DOUBLE DOOR UNIT W/SIDELITES WITH SIDELITE WITH SIDELITE ciZ WHERE WATER INFILTRATION PERFORMANCE IS DATE: TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE 5126117 CONFIG MAX WIDTH INSWING f OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HIGH DAM 0 S ,/,. sch : N.T.S. SHEET k DESCRIPTION X 37.5"___ +70.0 -70.0 +70.0 -70.0 N A +20.0 -2D.0 +30.0 -30.0 +50.0 -50.0 bX � DWG.ey: SINS 1 TYPICAL ELEVATIONS & GENERAL NOTES XX 74 +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 2 ANCHORING LOCATIONS & DETAILS OX or XO 7N- +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 CHK.BY. 3 ANCHORING LOCATIONS & DETAILS 0X0 112.5 +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 KURT BALTHAZOR DRAvaNG No.; OXXO 149 +55.0 -55.0 +55.0 -55.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 FLORIDA P.E. DWG-MA-FLO211-17 #56533 SHEET 1 OF 3 _oo 6" SEE DETAILJI 6" U 0 O 3• "E" 3" 3. J Q O 3" I 3" 3" r3 Qcl�J I I I ¢ (n p 6" 6" r 6" 6" —�6• 6. I Q 0_U n — NL _ n M1• L U nn ~ Lr)w 'Z a Qa SEE DETAIL E (n _ a W"D" — — LLI D o SEE DETAIL .C. — a o _ SEE DETAIL Lam- w "C" B w 8 O 0 o Lq A — A 6" B — G 'n — G H — n H = c o 6" 3" a 6" 6" 10 m z I I I r I � 1 " I �I m o� 6 7d 3" —I 3^ 3 3" 3^ I—g^ 6^TI I . e I` a a 6"3" SEE DETAIL71 6" #8 x 2" .F. m ASTRAGAL RETAINER BOLT HOLE #8 x 2" #10 x.5/8" MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE #10 x 5/8" STRUCTURE DEEP ENOUGH #8 x.2 FOR A 1.375" THROW#10 x 1" DETAIL "E" ASTRAGAL rn #10 x 2-1/2" ATTACH ASTRAGAL RETAINER BOLT DETAIL "F" ASTRAGAL o #10 x 1 STRIKE PLATE TO FRAME Lo #10 x 5/8" AS SHOWN. DETAIL "C" DETAIL "D" w 1 0.962" HOT MELT 1.375" � ELASTOMERS` 06 X 1-1/2^PMS T T INSWING THRESHOLD BUMPER 0/S THRESHOLD Q,BUMPER ? f Addedntowmi Z HOT MELT 1/2'BITE ELASTOMER '' •^ti••-' Ged(calionNu.W0137417 Reviewed Dale Aev eBw 5126117 1.482" 1.75" 11.047 EXIE814B 1NTEMPB N.T.S. TYPICAL GLAZING DETAIL DwG.ev: SWS I T T NON-IMPACT GLASS CHK.BY.- DRAWING NO.: Z-SERFHIGH DAM 0/S THRESHOLD S 0/S THRESHOLD . DWG-MA-FL0211-17 j SHEET 2 OF 3_ I SEE DETAIL6" 6" LL 00 Cr "E" SHT. 2 3" 3" 3" O '— 6" 3" 3" U 0 O J Q� LU Q n M U W D-SEE DETAIL ¢ U } "D" SHT. 2Ln } O OLO co r J SEE DETAIL 0 w a "L "C" SHT. 2 w — — w o '6 B A M A a G G H B 6^ 6- 6- r "6" �a r i Ir II rl li iWZo 3" 3" I C v a —3" 3.6LU- 6" 3. I`3" 69 1 SEE DETAIL 6" 6" p "F" SHT. 2 6^F[ o HARDWARE SCHEDULE ILf 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND m SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5=1/2" CENTERLINE. ATTACHMENT DETAIL 1.25": 't' MAX 2. 4" X 4" FULL MORTISE BUTT HINGES. 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, MAX ` 1"X1/2" CORRUGATED ;1/10X2" WOOD SCREW SIGNED AND SEALED BY ROBERTO LOMAS, PE SHIM 3" FROM EACH END 6 FROM EACH END cn (FLORIDA #62514) WITH THE LOWEST (LEAST) CL I_ AND 7" OC AND 12" OC z FASTENER RATING FROM THE DIFFERENT FASTENERS •. I Ln BEING CONSIDERED FOR USE. JAMB, HEAD, AND ACRYLIC � THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE LATEX #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL TYPICAL MASONRY ACRYLIC CAULK SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR ANCHOR INSTALLATION LATEX w LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". CAULK CL r WOOD SCREW EDGE DISTANCE MIN 3/4". I 0 o•', i COMBINATION WOOD COMBINATION WOOD 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1M5NMULLION (BOXED) MULLION (BOXED)ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT o.2s"MAX (31 OX2-1/2" zOF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE SHIM WOOD SCREWS AddenduoloNAMIMINIMUM EMBEDMENT OF 1-1/4 EACH END CL— — Celtifiealionk: O!? 4 DA1E• 5 26 17 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO90TRANSFER LOADS TO STRUCTURE. ® Da�epevev• N.T.S. DWG.BY. $W$ 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ® ® CHK.BY: TYPICAL WOOD BUCK ANCHOR INSTALLATION DRAWING No.: INTEGRAL WOOD DWG-MA-FL0211-17 MULLION (CHS) sNEU 3 of 3 L_ NOTICE OF PRODUCT CERTIFICATION .� � Company: Masonite International Corporation Certification No.: NI013747 1955 Powis Road Certification Date: 06/08/2017 West Chicago,IL 60185 Expiration Date: 06/30/2021 '* Product: Wood-Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites (w/Wood Frame unless noted) Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non-Impact Glazing: Insulating Glass(Tempered) The"Notice of Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listin at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute(ANSI). Inswing Glazed 'Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0"x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FL021 l-l7 X O/S Opaque 3'0"x 6'8" +70/-70 3.0 psP Yes ATLNC 1001.01-13 Single 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 XX I/S Opaque 6'0"x 6'8" +55/-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-171-021 l-l7 XX O/S Opaque 6'0"x 6'8" +55/-55 3.0 psf Yes NCTLr210-2930-1 Double 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0211-17 XO/OX I/S Opaque Door 6'0"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 XO/OX O/S Opaque Door 6'0"x 6'8" +55/-55 3.0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0211-17 OXO I/S Opaque Door 910"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 OXO O/S Opaque Door 910"x 6'8" +55/-55 3.0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50psf' AnchorDetails-DWG-MA-FL0211-17 OXXO I/S Opaque Door 12'4"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 OXXO O/S Opaque Door 12'4"x 6'8" +55/-55 3.0 psfl Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0211-17 1-Denotes Bumper Outswing Threshold 2-Denotes Z-Series Outswing Threshold 3-Hi-Dam Outswing Threshold National Accreditation&Management Institute,Inc./4794 George Washington Memorial Highway/Hayes,VA 23072 Tel: (804)684-5124/Fax: (804)684-5122 t NAMI AUTHORIZED SIGNATURE: