Product Approval Menu>Product or Application Search>Application List>Application Detail
- RECEIVED
FL* FL10674-R13
Application Type Revision MAR ] 5 1018
Code Version 2017
Application Status Approved Permitting Department
St. Lucie County
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity LIL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
V Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 ,01 COI. Nie.minen.pdf
Referenced Standard and Year(ot Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://caw-xv.floridabui Iding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/201'
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No ( FL10674_R13_II_2017_10—FINAL—ER—OC—ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant:N/A Verified By: Robert I. M. Nieminen PE- 59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER,Section 5. Evaluation Reports
F_L10674_R13_AE_2017_10_FINAL_ER_OC_ASPHALT
SHINGLES FL10674-RI3.pdf
Created by Independent Third Party: Yes
Back I�
J
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Cooyrinht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
0 F-TovTE 0
Safe
http://wwvv.floridabuilding.org/pr/pr_app_dtl.aspx?paranl=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRI�t,IITY ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: a`s„i,�nrn•,,r�0
k
1 -
Robert J.M.Nieminen,P.E. ,& 4:` . The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 "r �” �` Nieminen,P.E.on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6`h Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section PropertV Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
K22tt Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire+are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration*, TruDefinitions Duration', Durations Premium Cool, TruDefinitions Duration} Designer Color
Collection, TruDefinitionsOakridges, Oakridge* and WeatherGuards HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire* Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
CertificoteofAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2of8
RINI-Y ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„tt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Va,d=150 mph (V„n=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shineles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
e
Berkshire shingles require minimum five(5)nails per shingle.
WeatherGuard�HP shingles require minimum six(6)nails per shingle.
Devonshire"shingles require minimum six(6)nails per shingle.
Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
fel:,nderlayment Deck FeltunderYyment Deck Self-adhered
_ WeatherLock,
Self-adhered unnodaymenl
Weat herlocka i
/ underlayment
Drip Drip ed Drip edge
edga Or.
e 9 P
edge
's IncatedNall Ims
2-3'trom eave
i 2"-3'frumeave
hrst�!!first Self-sealing adhesive S�rseabng adhesive
Starter rust Sta
r s
Stripp ,y%�' positioned along eave hstal rtenip Pix poeitioned along eave
shingle with with 6'rcmoved
6"removed
Starter Strip shingle overhangs eaves and Takes'.1"-'i' Starter Strip Plus cverhangs eaves and rakes VC-314'
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
CertifrcateofAuthorization#9503 6"r EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
TRINITY ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
[7'7"
l Mansard or Area para Normal Mansard or Area para
reas High Wind desvones y Wind Areas High Wind desvanes y
Area para vientos normales Areas vientos fuertes Area porn vientos nonnnins Areas vientos fuertes
t.. 2 �" (A) t..l t• z", -(61 z• �•;
tt�` tr rzt _, i - tis
5"Exposure 5 WIr Exposure
Exposicidn Exposicidn
6.2.7 Minimum Nailing—Berkshire®:
Sealara~drip Sealant strip
/La lira do sabdar La Gra de setWor
-----------
[a:V2"=Y119tC
III Vy. Q121. 912" 8121, d Z
t
Standard Fastening Pattern 6-Nail Fastening Pattern
Soalant strip
La lira de Mlador
ff----------►e 4----------1-e e 04---------a,*
1"
r
1 _
\ i
P Asphalt roolinguxttent '
Camanlo de}echo do aslato
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6"EDITION(2017)FBC NON.HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
TRINITY ERD
6.2.8 Minimum Nailing—Devonshire'":
v n uTt
Rais
Grvos
Nails
TK
5.518"exposure
Exposicion de 5 J5/8 ping !
location I
Ubicaci6n del sellador
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition•
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nail Fastening Pattern
sur•NatlT.wslenmg ar—d1h r aunmalr fau rinY ar dth
Hall ryplemao I TypK
N 1
12" 12 1' 1� 11" 1
re
b1AEml
i
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
S�tto,ftswing a—
mm
Naa Tpn
t2_ 271 ..
f'T 7 _
�tra• s-srr�� Y 1 � I
Fau,1-span a Aspral Rwfinn C. t
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
ceftWoateofAuthoritotion#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R'13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY ERD
6.2.1 Minimum Nailing—TruDefinition'0akridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattern
Esauama con 4 clavus Fsquema cors 6 clavus
r �•
r r
Imo— rr ---►1 Imo— >z--�I {'F— v —� fA— 12 —�
66.1W Exposure6 6!0"ExposuretJails
rlaa�
.exposicicrrde55/Sp+dq. Clavus Expostc8indeoS/Spofq. 66.+8"Exposure clayus 6Ste"Exposure
Exposrddn ds 55/8pulg Exposiden de 5518polg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21'12
SurW4,l.Immmng aie+N^rn
H.O.ryprcal
r 12 i +r' r
Fou^, Spels of Aspnan Roofing rennni
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
r1• ��� t Single Slee View
W. 2'=r Vtsele♦lrMd
4'�:•-,�� :i��:•� C•:•a•: FiMrw7law�x Mail ti+a
Cance ew h llfw do�
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
CertlfiouteofAuthorization#9503 6'EDITION(2017)FSC NON-I1VHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard� HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge•" Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 s�, Fig.2
4 PrmvdNOWnd Difealon �+ lepw— SWeYiew
+Nk`+' Na1s ',�� Nails 1jy
n I I 1 r lop
pi ..LamrcPuleo T 1 T
7T3
A 1 t I I 1
rrr r i �I
--►4 it
lei
a I
1
-- 1
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.A y' Fig.C Hip&Ridge Shingle Fastening
-
P—Hing Wind /. ---- Top'llew
- DIISAbn \,
Nails Noes
--------------
iL
1
-"� s' I olpomp
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
CertiflaoteofAuthorization#9303 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1313
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
TRINITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard 1 t,
Wind Direction Fastening
5c lent Strip . _ Pattern
6'Exposure 2
.1 1I-
12' i � Sealant
Fasten 711 71, b`Exposure Exposed 1 `
Faxtetrore with
Roof Cement
t2"
6.3.6 Minimum Nailing–DuraRidget"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Ri.aifng Wind Diroccm To V tw
�—Diroaion dxninsnto ds♦ant Vat ea pan
Dimcdon dal ritrsto prodomimnto 1 Vista suptriot t
i r. Nal
Cla.
---� LAS •.`°,.',.
2 s�° . Owens Caning sweNair Caro
C�I016� 1 _s-77
r —
k �12- —�I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#003 6'"EDITION(2017)FEC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017