HomeMy WebLinkAboutProduct Approval - Shingles Florida Building Code Online Page 1 of?
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BQS Site Map Links Search
(Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL* FL10674-1113 F'L F. 0 rY,
Application Type Revision
Code Version 2017
Application Status Approved
RECEIVED
Comments
Archived MAR 15 2018
Product Manufacturer Owens Corning Permitting Department
Address/Phone/Email One Owens Corning Parkway St.LUCie County
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomlg.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Niemine_n.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.foridabuiIding.org/pr/pr_app_dtl.aspic?param=wGEVXQxvtDgtBNbEY5 V%2... 1/15/2018
Florida Building Code Online Page 2 of Z
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674_R13 R 2017 10 FINAL E�O_C_gSPHALT
Approved for use outside HVHZ:Yes SHINGLES FLj0674_R13tpdf
Impact Resistant: N/A Verified By: Robert 1.M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER, Section 5. Evaluation Reports
FL10674 1113 &E_2017 10 FINAL ER OC ASPHALT
$HINGE€S FL674 R13_pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 Sate of Florida.c Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F,S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
ED E-1 civ-"ovE�0
Safe
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-R13
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
•'•.�� "'c'-:` The facsimile seal appearing
Robert J.M. Nieminen,P.E. ,:.`' Robert
Nieminen,P.E.on 10/09/2017. This does not serve as
Florida Registration No.59166,Florida DCA ANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section PropertV Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shinales:
4.1.1 Classice and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration* Designer Color
Collection, TruDefinition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY ER®
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to V,,d = 150 mph (V„h = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Va:d=150 mph (V„it=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shinales:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
Berkshire shingles require minimum five(5)nails per shingle.
WeatherGuard�HP shingles require minimum six(6)nails per shingle.
Devonshire"shingles require minimum six(6)nails per shingle.
i Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Fe',: derlapment Deck feRunderlayment
Deck Selfwlwed
_ t4'eatherLocA.
Self-adhered unecrlayment
WeatherLock'
-ii•� underlayment
Drip edge
Drip— Drip edge Drip—
edge edge
Nails le ated Nets locaten
j -2-3'from eave
y.= 2"-3"front ea-ire
!list l!F.rstSclfaeal og adhes:e selfsealing adhesive
osit!oned alon
Starter Stripp '� Inststarter S:rip PIApositionedalong eave
shingle vrith ✓1 l p g eave al rust with 6'removed
6"removed overhangs eaves and rakes ='.i" Slater Strip Plus cverhan soaves and rakes tie•'-3i4'
Starter Strip shingle g 9
ff
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certifcater ofAuthoritotion#95a4 6'EDITION(2017)FBC NON-HVHZ EVALUATION r-L10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
i
TRINITY ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
NormI Mansard or Area para Normal Mansard or Area pare
Wind Areas High Wind desvasr•sy Wind Areas High Wind desvanes y
Area pare vientos normales Areas vienros fusrtas Area para vientos normales Areas vientos fuertes
IAI
tt ��1•—tr—.t" 1: iel rr t Vi t iIA) — , 21� 'It �{i �i61 r?' t''
5"Exposure
Esposieldn 5 WV Exposure
Exposioldn
6.2.7 Minimum Nailing—Berkshire°:
Sealam virip Sealant strip
La!ira de mbdor la tua de seliador
0-0
T.8l2' S Y' 9 6Y A t ' 8+7^ 8 t2' a ti' 6 11"
Standard Fastening Pattern 6-Nail Fastening Pattern
Saalani strip
13 lira de sallad�r
.•i---
00�----s• •.--s a ---�a
r YY' B YY 8 3Y'
1"
T \
Asphah rooling ooanent
Carmelo de iecho de asisko
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Cardfioats oJAuthoriratlon#9503 6r't EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
TRINITY ERQ
6.2.8 Minimum Nailing—Devonshire":
7"
I f;y�s
Gevas t
Nails_
- - •-- i \
5.5x8'exposure Sealant location
Exposid6n de 5.5/8 pulg Ubicaci6n del sellador
Ten V Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition<
Duration Designer Color Collection:
4-Nail Fastening Pattern "all Fastening Pattern
tiurKlrlfi arta wId01
EurtNmlFfastpnrtg area wMN
{�Nall.Typical Nbl Typ"
.�_ ..;-.:_:::.. .,�,-..<--- 'I.-.sK• ,,.. -:... ,� to-. '.., •. i..-, . .... ..
F1 I
t:tn-i say I t:,nF1 ` I +
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
Naa.TNMu,
1 12 1 I 1 12 t'
Four 1-Sp—at Aspt'.R R-fimq C-1
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certifkote ofAuthorkation M03 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY ERS
6.2.1 Minimum Nailing—Tru Definition'Oakridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattern
Esarterna con 4 clavos Esquenra torr 6 clavos
r r
1� t• t'
6618'Exposure pJai� 6 618"Exposure Wails
Exposldda do 5 5/S ptdg. Clam Exposkldn de'64 ping. 6 6/8"Expabule claros 5 518"Exposure
Exposkidn dr 55/8 ping. Exposioidn do 55/8pu(g.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 2112
r-S..wr., unmg are..a h
I6.1T S•S7' i I
Fou,1Spc%o,/lapha.R Rootleg Ceennt
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuardO HP:
r,• 1 51 a Nee Vew
� �..y�: :z.:;.ice �.:��•. F�r.r7f..�t Mrrl ai..
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
CertifiovteofAuthorization e+5!503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY ERL
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, WeatherGuardf HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 Fig.2
Pmwdlmvktnd
dreann � \�f•+\ T jQPvW" sme%Aw
WNs�--may � `�\�•.L�` T N7rs Nuts
r iosLan"
01
r �
4 � _
14
� r r
�Ggesae �
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.A Fig.C Hip&Ridge Shingle Fastening
—_. -9'
vrowm"gnewG�1•\, Topvkw
�—Dlroelbn \
—1
NNb`�— qq
} I Y
�.. Exposum
(,` I FYpO>rna
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-Rg
Certi�tzrre of Authari:ation 6'EDITION(2017)FBC NON-l-tVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
TRINITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard tt„_•
Wind Direction Fastening
Scehnt Strip . Pattern
6'Exposure
• �.
12' i ' Sealant
Fasten 7'h' 7 6'Exposulre
Cover Exposed
Fasteners with
Roof Cement ---iZ'
6.3.6 Minimum Nailing—DuraRidgeT'Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pro aiing Wind Diradm Top V*w
Direction dDmirunto di rcnt Vee ex pl to
Direcdon del tirnts prokmirunte I In.supervx I
f-� N 1
a
—r0' .:::..,. • ::scaring surcNair
Slow � � L
cava 1 I
as
v 1 1 Ia
l\ \ 1 I 1 I c
ZT
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate,of AuthorizationpA903 6r”EDITION(2017)FBC NON-HVFIZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8