Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
I I WARRIOR©ROOFING MA!NUFkCTURING i P.O.Box 40185 • TUSCALOOSA,AL 35404 • PHONE(205) 553-1'734 •! FAX(205) 553-1755 323 DEVELOPMENT AVENUE CHAMBERSBURG, PA 17201 PHONE(717);709-0323 FAX(717) 709-0027 I SAFETY DATA SHEET I Material Name: Asphalt Saturated Organic Roofing Underlijafiymen,It Chemical Family: Asphalt and Organic Felt Formula: Mixture ! !' Product Use: Secondary Water Barrier I, Product Name(s): 15w, 30w, #15ASTM, #30ASTM #15 Plain,!#30 Plain, #15 Felt, 430 Felt, 18" Split, #15 Perforated' Manufacturer: Warrior.Roofing Manufacturing 3050 Warrior Road Tuscaloosa, AL 35404 II I, Health and Technical Contacts: ' I Health Issue Info (8:00 AM - 5:00 PM US Central Time) 800-749-3358 Technical Product Info (8:00 AM - 5:00 PM US Central Time)j800-7,49-3358 o Emergency Contact: CHEMTREC (24 Hours Daily) 800-424-9300 I { i al Oki ` 1 • i Emergency Overview: Under normal use conditions and when ha,lridled as t intended, the products covered in this SDS are riot expected to pose a health risk or physical hazard to a fl iilu i WARRIOR® ROOFING MAN UFACT RING ll P.0.BOX 40185•TUSCALOOSA,AL 35404•PHONE(205)553-1734•FAX(205)553-1755 t; I i 193 LEROY ANDERSON ROAD•MONROE,GA 30655•PHONE(770)207.0695•FAX(770)207-0775 323 DEVELOPMENT AVENUE •CHAMBERSBURG,PA 17201 •PHONE(717)709.0323 •FA X(717)709-0027 r i SPECIFICATIONS i EI # 30 ASTM i Our#30 ASTM asphalt saturated organic felt is manufactured to meet or exceed the following: ASTM - D226,Type II -Commonly called No.30 Asphalt Felt I FED SPECIFICATION - HHR-595B,TYPE 30 U.L:,SPECIFICATION -U.L.STANDARD 55A FOR TYPE 30 ASPHALT SATURATED ORGANIC FELT I Dimensions and specifications of 30 ASTM asphalt felt are: Width of roll: 36"+/-0.7% �. Area: 216 sq. ft. Net mass of saturated felt: 26.0 lbs./100 sq. ft. Net mass of saturant: 15.0 lbs./100 sq. ft. I it Saturant Weight: Shall not be less than 1.51 times::the weight of the moisture free felt. I Packaging: The rolls arewrapped secVj:urely and the manufacturer's or distributor's name, type and specification markings are evident on the label. UPC bar codin g is included on all our labels. I r ; I NOTE: Yellow line is added per Dade County Florida buildhig specifications. Updated May 2013 � i, f r I humans. Potential Health Effects. i Inhalation: One should avoid high levels of dust (levels in excess of OSHA PEL or if irritation occurs). In the event of'a high dust level, an NIOSH approved disposable Oust respirator, properly fitted, should be,used.; i,. Skin Contact: A loose fitting, long sleeved cotton shirt, long cotton pants and gloves are recommended to avoid the potential of skin irritation. Eye Contact: Dust may cause stinging, redness or swelling. Ingestion: These products are not intended to be ingested;(eaten). In the event of accidental ingestion, short term irritation of the gastrointestinal tract (mouth, throat;°stomach, small and large intestines) may occur. HAZARD RATING(National Fire Protection Association) y REACTIVITY0 `' SPECIAL NOTE is Legend: 0- Minimal, 1 -Slight,,2 - Moderate, 3 - Serious,,, -Severe Name CAS Number Weight% !;OSHA'' ACGIH Organic Felt Paper NE <60 10 mg/m3 15 mg/m3 Asphalt Flux 8052-42-4 <70 5 fume 5 fume NE = Not Established is j IIS A1{/' M I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION �, ; Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) I, i:ww.miamidadc.gov/econnnv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails,to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or!material;fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. i DESCRIPTION: GAF Timberline Ultra HD°Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed4nd there has been no change in the applicable building code negatively affecting the performance of this product. I f ip TERMINATION of this NOA will occur after the expiration date or if there has been fa revisir on or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an,endors'ement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA.;Failure'to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the,NOA i�s'displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the Imanufdcturer pr its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1104.12 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. + NOA No.: 14-1022.21 QMLANMI-D�ADEUONTY j Expiration Date: 04/22/18 Approval Date:02/05/15 Page 1 of 5 i I I . ROOFING ASSEMBLY APPROVAL Category Roofing i Sub-Category: Asphalt Shingles Materials: Laminate I Deck Type: Wood i SCOPE This approves GAF Timberline Ultra HD®Shingles as manufactured by GAF'describecl in Section 2 of this Notice of Acceptance. I ,I PRODUCT DESCRIPTION i Product Dimensions Test ! Product Description Specifications GAF Timberline Ultra HD® 13'/4"x 393/8 TAS 110 Fiberglas reinforced heavy weight asphalt roof Manufacturing shingle,with a laminate profile. Locations# 1,2,3,4,5,6 MANUFACTURING LOCATION i 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Ennis,TX ! 5. Myerstown, PA ' 6. Tuscaloosa,AL EVIDENCE SUBMITTED I ' Test A2ency Test Identifier Test Name/Report Date I Underwriters Laboratories, Inc. ASTM D 3462 02NK4180�' 11/08/02 TAS 107 02NK418 H 11/11/02 TAS 107 03CA35209 10/17/03 ! ASTM D 3462 03NK2644'4, 10/17/03 TAS 107 05CA42840! 11/11/05 TAS 107 05CA4754i1 05/10/06 ASTM D3462 066A10139 09/13/06 TAS 107 j PRI Asphalt Technologies, Inc. TAS 100 ELK-,108-021'01 10/14/03 i TAS 100 ELK-084-02'-01 10/30/02 TAS 100 ELK-087-02'!01 10/30/02 TAS 100 GAF-646-02"()l 04/05/04 TAS 100 GAF,100-02,;01 11/16/08 ASTM D 3462 GAF,100-02'02 11/16/05 TAS 100 GAF'103-02!-01 11/16/05 ASTM D 3462 GAF;103-02 02 11/16/05 NOA No.: 14-1022.21 Miarn•oaoecouNrir Expiration Date: 04/22/18 PENMAN Approval Date:02/05/15 Page 2 of 5 9 I LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A',attached. 5: Nailing shall be in compliance with Detail'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: !' Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code:in order to properly evaluate the installation of this material. I i t I I it I NOA No.: 14-1022.21 MIAMI•DADE COUNTY Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 3 of 5 i . I I ; I DETAIL A ' I COURSE LAYOUT DECK I f' I ' FULL ' 5th r � 17" OFF 4th �I 11"OFF 3rd 6" OFF i2nd 5-5/8" Exposure FULL 1st I I I I I i NOA No.: 14-1022.21 QM[AW-DADEMMOUN Expiration Date:04/22/18 Approval Date: 02/05/15 I ' Page 4 of 5 DETAIL B—13-1/4"X 39-3/8" OVERALL DIMENSIONS AND NAILING PATTERN I i ! - Release I --- -- ------- -- ----- .. -- -- - Tape 6 fasteners -- 72 134" i-- -- ; r -� 5- - 6-4 4 5-5/8" A Front Side (Maximum Slope 21:12) Tab Sealant I ! 3/8" 112" Back Side I I GAF TIMBERLINE ULTRA HD6 f i END OF THIS ACCEPTANCE 1!;' � j 6 i NOA No.: 14-1022.21 MIAMI•DADE COUNTY Expiration Date:04/22/18 Approval Date:02/05/15 Page 5 of 5 i f f ,