Loading...
HomeMy WebLinkAboutProdudct Approval - skylight RECEIVED MAR 16 2018 MIAMI- ;dIAMI-DADE COUNTY Permitting De artmen St. LucieCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 1'(786)315-259D F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Sun-Tek Manufacturing,Inc. 10303 General Drive F I L F 17 Orlando,FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Hurricane Self Flashing(HSF)Aluminum Skylight APPROVAL DOCUMENT:Drawing No. HSF-002,titled"HSF", sheets 1 and 2 of 2,dated 01/27/2001, with revision dated 05/04/2015,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D. Wells,Jr.,P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state, model/series and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises&renews NOA#12-0424.05 and consists of this page 1 and evidence submitted pages E-1&E-2 as well as approval document mentioned above. The submitted documentation was reviewed by H lmy A.Makar,P.E•,M.S. Ww,,� NOA No. 15-0513.07 CMLAMI•DADECOUIYTY Expiration Date:01/10/2021 /0 /S Approval Date: 11/05/2015 Page 1 Sun-Tek Manufacturing,Inc.. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.HSF-002,titled"HSF",sheets 1 and 2 of 2,dated 01/27/2001,with revision dated 12/15/2010,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D. Wells,Jr.,P.E. B. TESTS "Submitted under NOA #11-0104-09" 1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5)Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of HSF Polyearbonate Aluminum Fixed Skylights,prepared by National Certified Testing Laboratories,Test Reports No. 210- 3716-1,dated 11/22/2010,with a revision dated 03/07/2010,signed and sealed by Gerard J. Ferrara,P.E. C. CALCULATIONS "Submitted under NOA #11-0104-09" 1. Anchor calculations prepared by J&L Wells Consulting LLC,dated 01/04/2011,signed and sealed by James D. Wells,Jr.,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Permitting,Environment,and Regulatory Affairs(PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 12-0110.04 issued to Palram Americas,Inc. for their"Corrugated and Flat Polycarbonate Panels",approved on 02/23/2012 and expiring on 01/22/2016. 2. Notice of Acceptance No. 08-0305.02 issued to SABIC Innovative Plastics for their"Lexan Sheet Products approved on 04/24/2008 and expiring on 07/17/2013. 3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics,Inc.,for their"Makrolon Polycarbonate Sheets"approved on 07/07/2010 and expiring on 08/27/2012. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by J&L Wells Consulting LLC, dated 04/25/2012,signed and sealed by James D.Wells,Jr.,P.E. "Submitted under NOA #11-0104-09" 2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J&L Wells Consulting LLC,dated 03/17/2011,signed and sealed by James D.Wells,Jr.,P.E. WlhV A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 15-0513.07 Expiration Date: 01/10/2021 Approval Date: 11/05/2015 E-1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. HSF-002, titled "HSF", sheets 1 and 2 of 2, dated 01127/2001, with revision dated 0510412015,prepared by Sun-Tek Manufacturing, Inc., signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County, Regulatory and Economic Resources Department (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2014 FBC issued by J&L Wells Consulting LLC, dated 05105/2015, signed and sealed by James D. Wells, Jr., P.E. my A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.07 Expiration Date: 01/10/2021 Approval Date: 11/05/2015 E-2 PART NAME: PRODUCT DRAWING I SHEET 1 OF 2 DRAWN BY: L. B. REED OUTER DOME .093 POLYCARBONATE SILCONE DOME SEAL (Palram Palsun, Sabic Lexan 9034 or SHeffield Makrolon) (CONTINOUS) DECO CLIP .060 6063 T-6 ALUMNIUM - #6 X STI-217 INSULATED AIR SPACE SELI 8 PE r' ITS BUTYL SEALING TAPE �- INNER DOME .080 (CONTINOUS) POLYCARBONATE (Palram Palsun, FRAME .080 Sabic Lexan 9034 or Sheffield Makrolon)) 6063 T-6 ALl STI-207 CORNERSN DESIGN PRESSURE RATING INSULATION OR AND WELDE +- 60 PSF AIR SPACE LARGE MISSLE IMPACT RESISTANCE PVC LINER Engineer ofReeor& STI-300 James D.Wells,Jr.,P.E. STS 1000 SEALANT COMPLY WITH SECTION 2612 Professional EngineerNc CONTINOUS UNDER FRAME OF THE F.B.C. AROUND PERIMETER OVER HEADS OF SCREWS J&L WELLS CONSULTIN NOTE: 1453 Arbiws Circle (1) ALL ROOF DETAILS SHALL COMPLY WITH Oviedo,FL 32765 CHAPTER 15 OF THE 2014 FLORIDA BUILDING (407)496-5019 ofAu Certificate of Authorizad00 N0. CODE. (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO IL T �— ROOF SURFACE FOR SHINGLES OR B.U.R. — WITHOUT INSULATION. FOR INSULATION --Z 1 0.25" AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKTHE 4" MINIMUM HEIGHT. 48 X 1" PHILLIPS PAN HEAD MINI.1/4"PROTRUSION �ytr THROUGH ROOF DECK ROOF DECK MIN = o. 53616 �*= 8 PER SIDE s " THICKNESS =p.% W I�7'6 sz STATE OF �: REVISION: 2.15. REVSIO : PRODUCT NAME: ORIO �������••' � - — - - SUN-TEK MANUF NIINC HS 70303 GENERAL DRIVE10 DATE01/27/01SCALE: i � DWG No. F-002 PART NAME: PL_AN_VIEW HSF _ SHEET 2 OF 2 _ DRAWN BY: L. B. REED 54.50 NOTE: 4.00 (1) ALL ROOF DETAILS SHALL COMPLY WITH 6.75 CHAPTER 15 OF THE 2014 FLORIDA BUILDING �67 m CODE. 4.00 �—6.75 00 (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO r 6.00 0.63 9 ROOF SURFACE FOR SHINGLES OR B.U.R. LIP WITHOUT INSULATION. FOR INSULATION RC SURI AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO THE 4" MINIMUM N HEIGHT. o 0 co 1- 32 FASTENERS FRAME TO DECK POLYCARBONATE DOME .093 THICK 0 I co (Palram Palsun, Sheffield Makrolon or Sabic Lexan 9034)) lA N C) (6 HSF 4646 co POLYCARBONATE DOME .080 THICK / — – (PaIram Palsun, Sheffield Makrolon or Sabic Lexan 9034) LoS -- -- ----- c° SYME ERICAL co - J&L WELLS CONSULTING LLC Engineer 1 ngm of Record: 433 Ati�lws Circle Oviedo PL 32765 James D.Walls,Jr,P.E. (407)496-5489 Professional Engineer No.53616 Cardflcate of Atd wiradon No.27162 32 FASTENERS D CO RING TO FRANE DESIGN PRESSURE RATING +- 60 PSF moovc•imvIsEi LARGE MISSLE IMPACT RESISTANCE BI,Ic�gtc do iththi ——" -- Accopuutca No 16-4 P"Wn Data i,'�e E By FASTENER SCHEDULE FRAME TO DECK FASTENER SCHEDULE DECO RING TO FRAME #8 X 1 PHILLIPS PAN HEAD SCREWS #6 X 3/4 HEX HEAD SELF DRILLING SCREWS MODEL PER LONG SIDEPER SHORT SIDE MODEL PER LONG SIDE PER SHORT SIDE 4646 8 _ 8 _ 4646 8 8_ 3046 8 6 3046_ 8 6 ------------ = 3636 --- 77 3636 --— --- 7 7 2246 8 - -- -- 5 2246 8 5 2222 5 5 -- 2222 - - 5 5 REVISION: REVISION: PRODUCT NAME: HSF SUN-TE K INI: INI: DATE:01/28!01ALE: I DWG No. HSF-002 INDUSTRIES, INC