Loading...
HomeMy WebLinkAboutProduct Approval (4) Florida Building Code Online 1Mrfxma+ BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search (T !-� flt�c3 — Product Approval ,USER. Public User Product Anoroval Menu>Application Detall FL# OApproved Application Type Code Version Application Status Comments Archived Product Manufacturer Regency Plus Incorporated Address/Phone/Email 2000 Locust Gap Highway Mount Carmel, PA 17851 (570)339-3374 tonyp@conservationwindows.com Authorized Signature Tony Procopio tonyp@conservationwindows.com Technical Representative Joe Korzeniecki Address/Phone/Email 2000 Locust Gap Hwy. Mount Carmel, SD 17851 (570)339-3374 joek@window-pros.info Quality Assurance Representative Joe Korzeniecki Address/Phone/Email 2000 Locust Gap Hwy. Mount Carmel, PA 17851 (570)339-3374 joek@wlndow-pros.info Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/NWWDA101/I.S.2-97 1997 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv8JygqZ9WuENUVNORIPIFJyICW4TxaBb60vhQflcOe3%2bg%3d%3d[2/l/2018 4:16:20 PM] Florida Building Code Online 01 affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONO ON/A FL11412 R6 COG Affirmation FL11412 417-0906 ss odf Product Approval Method Method 1 Option A Date Submitted 01/04/2018 Date Validated 01/04/2018 Date Pending FBC Approval Date Approved 01/09/2018 Summary of Products r. j FL# Model, Number or Name Description 11412.1 Series 2000 Series 2000 Non-Impact Single Hung Window L Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL11412 R6 C CAC NI006135-R8 Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date j Impact Resistant: No 12/31/2021 Design Pressure: +40/-40 Installation Instructions Other: FL11412 R6 II 08-02703.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL11412 R6 AE 513483.pdf Created by Independent Third Party: Yes ---- ................ --- - 11412.2 Tech 5000 Series Tech 5000 Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11412 R6 C CAC NIO06712-R4.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 03/31/2021 Design Pressure: +55/-55 Installation Instructions Other: FRAME MATERIAL TO BE RIGID PVC FROM ROYAL FL11412 R6 II 08-02704A.pdf WINDOW&DOOR PROFILES, PLANT 1,VEKA AAMA CERTIFIED Verified By: Luis R. Lomas, P.E. 62514 (DOM-1). Created by Independent Third Party: Yes Evaluation Reports FL11412 R6 AE 13-0328.09-COMP.pdf FL11412 R6 AE 13032809.pdf FL11412 R6 AE 513484A pdf Created by Independent Third Party: Yes Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer,Cooyriaht 2007-2013 State of Florida.:;Privacy Statement::Accessibility Statement:;Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: rCheck M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dti.aspx?paratn=wGE V XQwtDgv8JygqZ9 W uENU VNORIP I FJy I C W 4TxaBb6OvhQHcOe3"/2bg%3d%3d[2/I/2018 4:16:20 PM] L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541 Report No.: 513484A 434-698-0609 rl lomas'rr,;lrlomaspe.com Manufacturer: Regency Plus, Inc. 1024 Locust Gap Highway Mt. Camel, PA 17851 Product Line: eries Tech 5000 Vinyl Single Hung Window-52"x 76" LMI Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document:drawing number 08-02704, Revision A, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: NCTL 210-29-68-1,2,3 signed and sealed by Gerard J. Ferrara, P.E.. National Certified Testing Laboratories,Orlando, FL. TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure, t55.Opsf design pressure, 13.5psf water penetration. TAS 203-94 Cyclic Pressure loading t55.Opsf design pressure 3. Anchor calculations,report number 513484-1,prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: t55.Opsf • Maximum unit size: 52"x 76" • Units must be glazed per ASTM E 1300-04, see installation instructions for glass details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind bome debris regions. Frame material to be rigid PVC. nsta a ion: nits must a installed in accordance with approval document, 08-02704, Revision A. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also. I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). \V��11111i1//���/ � J • CEN q �� • 051 • >k �� • TAT OF ;cam-.. �� ii��`s:cZ OR Ot G�� ` is/ONAt �?\\\� 1111l 1 of 1 Luis R. Lomas, P.E. FL No.:62514 08/14/2015 7 f till R. IP(j. "R `T-4 r Pj�i K -4 Ali A I" 0 J 1 r I iA f 0 1- i k 4V i V 'N A:I.. L.+- K 0A s7j, -i: rr- AV A-F R Ci S f.. D Ml%Y J,. 1 13 0 Mi.N JNfr� A I AE N N i AN.IN�,!Pt C�fIA]i S. IN'(' ..,.;0 JSEe '�Jlc 0N1 rrAf?MF'vf 111 T(j F. W A T A*,I A.. -A A! SIGNED:0811712015 REGENCY PLUS, INC. \\\%%I I I ft..L 0',V, 2000 LOCUST GAP HIGHWAY MT CARMEL. PA 17851 N f-ee SERIES TECH 5000 VINYL SINGLE HUNG 'A"W710IN0 0 52" X 76" — LMI NOTES !:�lo M-. TATF- OF 0, 41t '5', ZOR%lA-'0-' 08-02/04 06/01/15 OF 4 L _ i a,. I Ar 4 X INTERIOR EXTERIOR i SERIES TECH 5000 VINYL SINGLE HUNG WINDOW EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING +55.OPSF LARGE AND SMALL MISSILE IMPACT GLAZING DETAIL MISSILE LEVEL D,WIND ZONE 4 8 HVHZ SIGNED:0847.12015 REGENCY PLUS, INC. \�1�111II'III/7,, 2000 LOCUST GAP HIGHWAY `� �5 R. L pA,V�� MT CARMEL. PA 17851 v•��GEN8F9S�� HARDWARE SCHEDULE SERIES TECH 5000 VINYL SINGLE HUNG WINDOW =*� 0 51 *� A. (1 METAL CAM-TYPE SWEEP LOCK 111/2"FROM EACH END OF INTERIOR MEETING STILE 52" X 76" — LMI �~��5 B. (1 METAL KEEPER AT EXTERIOR FIXED MEETING STILE ELEVATION TATE OF �Vcc` C. (1)METAL TILT LATCH WITH THUMB ACTUATOR AT EACH END OF SASH TOP RAIL "^h' �� �`S.c�OR110'- D. (1)DIE-CAST METAL PIVOT BAR INA NYLON SHOE N.C. 08-02 04 E. (1)STEEL REINFORCEMENTSQUARE-SHAPED AT MEETING RAIL I NIS 06/01/15 '2 OF 4 INTERIOR a i INTERIOR EXTERIOR JAMB INSTALLATION DETAIL INTERIOR '! .. S i METAL STRUCTURE INSTALLATION :.-...� �. EXTERIOR I _ INTERIOR EXTERIOR 1 �-« ix I r� r I z Wo .......... EXTERIOR JAMB INSTALLATION DETAIL I -- WOOD FRAMING OR2X BUCK INSTALLATION VERTICAL CROSS SECTION :08/17/2015 VERTICAL_CROSS SECTION METAL STRUCTURE INSTALLATION REGENCY PLUS, INC. WOOD FRAMING OR 2X SUCK INSTALLATION2000 LOCUST GAP HIGHWAY \\\��� •L0.ZjV/� MT CARMEL. PA 17851 `r.��CENa 'p F• _ SERIES TECH 5000 VINYL SINGLE HUNG WINDOW • p *� NOTES: 52" X 76" — LMI !;AeATP�OFJ4 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, INSTALLATION DETAILS , NOT SHOWN FOR CLARITY. �Q�• � lv\ 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BEs'.�OR1�PG\�'�� DESIGNED IN ACCORDANCE WITH ASTME2112 N.C. ,_r, 08-02704 A �iONAL1��\�`� NTS 06/01/15 3 OF 4 _ .......... .... __ 1 INTERIOR i I EXTERIOR ' �' INTERIOR EXTERIOR JAMB INSTALLATION DETAIL CONCRETEiMASONRY INSTALLATION NOTES: 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. �^ 1 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 ` 4 SIGNED:08/1712015 Z I•,c.;; REGENCY PS ` 2000L CUSTGAHIGHWAY ♦♦♦`\�Stll � /',, MT CARMEL. PA 17851 •��CENSF 9`t'��� SERIES TECH 5000 VINYL SINGLE HUNG WINDOW �>ir• �r(0syt�j��6 *� S52"TA X 76" - LMI J•0 �� a� INSTALLATION DETAILS X11, TAT OF 4uz VERTICAL CROSS SECTION i0• k,� CONCRETEIMASONRYINSTALLATION P;A'XOR10. ♦�`�� N,G. 08-02704 A sS'ONAIttiaG`�\ NTS "` 06/01/15 1""'-4 OF 4