HomeMy WebLinkAbout17101811 - 16' NOA 48-52MIAMI•DADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
DAB Door Company, Inc.
12195 NW 98" Avenue
Hialeah Gardens, FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined
by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Hurricane Master Model 824/811 Steel Sectional Garage Door up to 16'-2" w/
Window Lite Option (DP +48.0,-52.0 PSF)
APPROVAL DOCUMENT: Drawing No. 98-05 Rev M, titled "24 GA. Roll Formed Steel Sectional
Garage Door", dated 02/23/1998 and last revised on OCT 03, 2017, sheets 1 through 6 of 6, prepared by Al-
Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product
Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade
County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model/series
number, the positive and negative design pressure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 15-0302.01 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Ishaq I. Chanda, P.E.
MIAMI•DADE COUNTY
NOA No. 17-1018.11
Expiration Date: July 21, 2020
Approval Date: December 14, 2017
Page 1
DAB Door Company, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
Evidence submitted in previous files
A. DRAWINGS
1. Drawing No. 98-05, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated
02/23/1998, with last revision L dated 03/05/2015, sheets 1 through 6 of 6, prepared by Al-
Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
B. TESTS "Submitted under NOA # 11-0414.13"
1. Test Report on Uniform Static Air Pressure Test, Loading and Forced Entry Test per FBC,
TAS 202-94, of "DAB 824 Sectional Residential Garage Door" prepared by Hurricane
Engineering & Testing Inc., Report No. HETI-07-4267, dated 06/29/2007, signed and sealed
by Candido F. Font, P.E.
2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure
Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by
Hurricane Engineering & Testing Inc., Report No. HETI-11-3206, dated 02/10/2011, signed
and sealed by Candido F. Font, P.E.
3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)",
prepared by Hurricane Engineering & Testing Inc, Report No. HETI-11-T101, dated
01/29/2011, signed and sealed by Candido F. Font, P.E.
"Submitted under NOA # 05-0217.02"
4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional
Residential Door with Windows" prepared by Hurricane Engineering & Testing Inc., Test
Report No. HETI 03-1328, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, PE.
5. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door" prepared by
Hurricane Engineering & Testing Inc., Test Report No. HETI 03-1329, dated 07/15/2003
signed and sealed by Rafael E. Droz-Seda, P.E.
6. Test Report on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)" prepared
by Hurricane Engineering & Testing Inc, Test Report No. HETI 03-T078, dated 10/31/2003,
signed and sealed by Rafael E. Droz-Seda, P.E.
"Submitted under NOA # 03-0210.04"
7. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels,
prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A.
Jackson, P.E.
C. CALCULATIONS "Submitted under NOA # 14-0814.08"
1. Anchor verification calculations prepared by AI-Farooq Corporation, dated
09/22/2014 and 07/24/2014, signed and sealed by Javad Ahmad, P.E.
I haq 1. Chanda, P.E.
Product Control Examiner
NOA No. 17-1018.11
Expiration Date: July 21, 2020
Approval Date: December 14, 2017
E-1
DAB Door Company, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
C. CALCULATIONS (Cont.) "Submitted under NOA # 09-0128.01"
2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0
2007, dated 04/05/2011, signed and sealed by Javad Ahmad, P.E.
"Submitted under NOA # 09-0128.01"
3. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0
2007, dated 12/18/2008, signed and sealed by Humayoun Farooq, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 13-0717.01, issued to SABIC Innovative Plastics, for their
Lexan Sheet Products, approved on 11/28/2013 and expiring on 07/17/2018.
2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam, LLC, for their
Insulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on
11/29/2017.
3. Notice of Acceptance No. 11-0926.07, issued to Dyplast Products, LLC, for their Expanded
Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/11/2017.
4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their
Dyplast ISO -C I Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on
01/11/2017.
5. Notice of Acceptance No. 10-1129.04, issued to Cellofoam North America Inc, for
their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and
expiring on 02/24/2016.
"Submitted under NOA # 05-0228.02"
6. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per
ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering &
Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E.
Droz-Seda, P.E.
7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material", prepared by
Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed
and sealed by I. Ghia, P.E.
8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test
of "BEHAU non -foam PVC extrusion material', prepared by ETC Laboratories, Report No.
04-761-15019.0, dated 05/06/2004, signed and sealed by L L. Doldan, P.E.
F. STATEMENTS "Submitted under NOA # 14-0814.08"
1. Statement letter of code conformance to the 5' edition (2014) FBC and no financial interest
issued by Al-Farooq Corporation, dated 05/13/2014, signed and sealed by Javad Ahmad, P.E.
�-
Ish q I. Chanda, P.E.
Product Control Examiner
NOA No. 17-1018.11
Expiration Date: July 21, 2020
Approval Date: December 14, 2017
E -2
DAB Door Company, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUB
2. New Evidence submitted.
A. DRAWINGS
1. Drawing No. 98-05 Rev M, titled "24 GA. Roll Formed Steel Sectional Garage Door",
dated 02/23/1998 and last revised on OCT 03, 2017, prepared by Al-Farooq Corporation,
signed and sealed by Javad Ahmad, P.E.
Note: This revision consist of editorial changes to comply with FBC 2017.
B. CALCULATIONS
1. None
C. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
D. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-0221.06, issued to Insulfoam, LLC, for their
Insulfoam Expanded Polystyrene Insulation, expiring on 11/29/2022.
2. Notice of Acceptance No. 16-1108.04, issued to Dyplast Products, LLC, for their Dyplast
ISO -C1 Polyisocyanurate Insulation, expiring on 01/11/2022.
3. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America Inc, for their
Expanded Polystyrene Block Insulation, expiring on 02/24/2021.
4. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan Sheet
Products, expiring on 07/17/2018.
E. STATEMENTS
1. Statement letter of conformance to FBC 2014 (51h Edition) and FBC 2017 (611 Edition),
prepared by Al Farooq Corporation, dated 10/05/17, signed and sealed by Javad Ahmad,
P.E.
F. OTHER
1. This NOA revises NOA #15-0302.01, expiring 07/21/20
Ishaq I. Chanda, P.E.
Product Control Examiner
NOA No. 17-1018.11
Expiration Date: July 21, 2020
Approval Date: December 14, 2017
E -3
IO 7-1/2" X 2-1/4" X 18 GA.
GALV. STEEL CENTER HINGE
O W/ (4) #14 X 5/8" SMS
WITHOUT DELRON SLEEVE (STD.)
O 7-1/2" X 3" X .071" GALV. STEEL
END ROLLER HINGE
I W/ (6) #14 X 5/8" SMS
WITHOUT DELRON SLEEVE (STD.)
WITH DELRON SLEEVE (OPTIONAL)
TOP FIXTURE 5-1/2" X 2-3/4" X 0.1"
NUT STEEL PLATE WITH ONE 5/16-18 MS W/ NUT
�FASTENED TO END STILE WITH
(6) S14 X 3/4" SELF DRILLING SCREWS
SEE SHEET 4 FOR TOP BRACKET OPTIONS
CFNTFR CTII FC
O `y ,
7-1/2" X 2-1/4" X .071" \ O+
GALV. STEEL CENTER HINGE -
O W/ (4) #14 X 5/8" SMS LOCK
WITH DELRON SLEEVE (OPTIONAL) 2/ DOOR \
a\
CENTER HINGE 1" W X .15 THK. LATCH
STANDARD LOCK r
\� SPRING LOADED SLIDE BOLT (BOTH SIDES
FASTENED W/ (4) #14 X 1/2" S.M.S. `�\ B
5/8" MIN. LOCK ENGAGEMENT
CONFORMS TO SECTION 1008 REGARDING
GARAGE DOORS `
.158 DIA. GALV. AIRCRAFT TYPE
CABLE & NICO -PRESS SLEEVE
W/ MIN. 5 TO 1 SAFETY FACTOR
7" X 3" X 0.1"
STEEL PLATE
WITH (4) #14 X 3/4"
SELF DRILLING SCREWS
i o
m
I
L O
BRACKET
STD. LIFT DOOR
DOOR
HEIGHT CONSISTS OF
TOTAL # OF
'U' BARS AT
EACH DOOR
6'-6" 2 SECTIONS 18" 2 SECTIONS 21"
3
6'-9" 1 SECTION 18" 3 SECTIONS 21"
7' 4 SECTIONS 21" -
7'-3" - -
7'-6" 5 SECTIONS 18" -
7'-9" 4 SECTIONS 18" 1 SECTION 21"
8' 3 SECTIONS 18' 2 SECTIONS 21"
8'-3' 12 SECTIONS 18" 3 SECTIONS 21"
4
8'-6" 1 SECTION 18" 4 SECTIONS 21"
8'-9" 5 SECTIONS 21" -
9' 6 SECTIONS 18" -
9'-3" 5 SECTIONS 18" 1 SECTION 21"
9'-6" 4 SECTIONS 18" 2 SECTIONS 21"
9'-9" 3 SECTIONS 18" 3 SECTIONS 21"
10' 2 SECTIONS 18" 4 SECTIONS 21'
10'-3" 1 SECTION 18" 5 SECTIONS 21"
10'-6" 6 SECTIONS 21" -
10'-9" 6 SECTIONS 18".1 SECTION 21"
5
11' 5 SECTIONS 18" 2 SECTIONS 21"
11'-3" 4 SECTIONS 18" 3 SECTIONS 21"
11'-6" 3 SECTIONS 18" 4 SECTIONS 21"
11'-9" 2 SECTIONS 18" 5 SECTIONS 21"
12' 1 SECTIONS 18" 6 SECTIONS 21'
12'-3" 7 SECTIONS 21" -
12'-6" 6 SECTIONS 18" 2 SECTIONS 21"
12'-9" 5 SECTIONS 18" 3 SECTIONS 21"
13' 4 SECTIONS 18" 4 SECTIONS 21"
13'-3" 3 SECTIONS 18".5 SECTIONS 21"
13'-6" 2 SECTIONS 18" 6 SECTIONS 21"
6
13'-9" 1 SECTION 18" 7 SECTIONS 21"
14' 8 SECTIONS 21" -
14'-3" 6 SECTIONS 18" 3 SECTIONS 21"
14'-6" 5 SECTIONS 18" 4 SECTIONS 21"
14'-9" 4 SECTIONS 18" 5 SECTIONS 21"
15' 3 SECTIONS 18" 6 SECTIONS 21"
15'-3" 2 SECTIONS 18" 7 SECTIONS 21"
15'-6" 1 SECTION 18" 8 SECTIONS 21'
15'-9" 9 SECTIONS 21" -
16' 6 SECTIONS 18-14 SECTIONS 21"
VA0
O
° N
BRACKET
LOW HEADROOM
DOOR OPTION
7-7/8" X 3-1/8" X .010" \
STEEL PLATE
WITH (4) #14 X 3/4" SDS
CENTER STILE
IF
OPTIONAL DOOR VIEWER
TO BE INSTALLED AT
ANY CENTER STIL�
10 -Z
DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA
THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT INSIDE ELEVATION BUILDING CODE, TAS -202, TAS -201 & TAS -203 FOR HVHZ AND
RAISED PANEL EMBOSSED DOOR ASTM E1886-05/ASTM E1996-09.
END STILE
LOCK BAR GUIDES
ON END STILE
ffH (4) #14 X 5/8" SMS
JIWNSTALLED
X .6W LOCK BAR
GES IN TRACK
ON EACH SIDE OF DOOR CENTER STILES
OUTSIDE KEYED LOCK
OPTIONAL
LOCK BAR LOCKING SHOWN
ALTERNATE TO
SPRING LOADED SLIDE BOLT
LOCKS SHOWN ABOVE
8'-0" TO W-10"
DAB DOORS INC.
Hurricane Master® Model 824/811
Max. Size 16'-2" X 16'-0" High
With Window Lite Option
DESIGN PRESSURE RATING = + 48.0 PSF
- 52.0 PSF
SCHEDULE 'A'
CENTER STILES CONFIGURATION
DOOR WIDTHS
# OF CENTER STILES
B'-0" TO 9'-10"
2
10'-0" TO 11'-10"
2
12'-0" TO 13'-10"
3
14'-0" TO 15'-10"
4
15'-11" TO 16'-2"
5
1
110711
17t],
10 -Z
DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA
THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT INSIDE ELEVATION BUILDING CODE, TAS -202, TAS -201 & TAS -203 FOR HVHZ AND
RAISED PANEL EMBOSSED DOOR ASTM E1886-05/ASTM E1996-09.
END STILE
LOCK BAR GUIDES
ON END STILE
ffH (4) #14 X 5/8" SMS
JIWNSTALLED
X .6W LOCK BAR
GES IN TRACK
ON EACH SIDE OF DOOR CENTER STILES
OUTSIDE KEYED LOCK
OPTIONAL
LOCK BAR LOCKING SHOWN
ALTERNATE TO
SPRING LOADED SLIDE BOLT
LOCKS SHOWN ABOVE
8'-0" TO W-10"
DAB DOORS INC.
Hurricane Master® Model 824/811
Max. Size 16'-2" X 16'-0" High
With Window Lite Option
DESIGN PRESSURE RATING = + 48.0 PSF
- 52.0 PSF
SCHEDULE 'A'
CENTER STILES CONFIGURATION
DOOR WIDTHS
# OF CENTER STILES
B'-0" TO 9'-10"
2
10'-0" TO 11'-10"
2
12'-0" TO 13'-10"
3
14'-0" TO 15'-10"
4
15'-11" TO 16'-2"
5
GENERAL NOTES
1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE
REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA
BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
2. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS
AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE
MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.
3. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.
4. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT
COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE
REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS
5. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION
FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY
OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR
WATER INFILTRATION RESISTANCE ETC.
CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY,
AND TO BE REVIEWED BY BUILDING OFFICIAL.
6. MANUFACTURER'S LABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION
IN ACCORDANCE WITH SECTION 1709.9.3 OF FLORIDA BUILDING CODE.
LABELING TO COMPLY WITH SECTION 1709.9.2. 111119t
to%mu
Zn
m
Z M W
F W �
CL
aCL $«
0 N
0 OO
d`a
��W N
0 U N
O'eIL�
0 IL 0
0��ix�
0 N
a W jLL
1LW 'a
m
0W¢ w
a ZME r
14 X 3/4' SELF DRILLING SCREWS o ✓
siitRe MAY BE USED
IN LIEU OF #14 X 5/8" SMS o F
cNoPT-(D/ °) 10'-0" TO 11'-10"_ 14'-0" TO 15'-10" _ m 0582
Diate 6 ''.O DOOR WIDTHS DOOR WIDTHS
0
e
®®�•, S4 T€11 4,t < ['drawing7no.
-�c®�a®�..,98—
REFEU TEAR PLAC EM 12 DOOR WIDTHS -10" ( `o- 15'DOOR WIDTHS 2 °°°�11�\ \``` sheet 1 of 6
SCERON 4 SCETION 8 SCETION 8
L7U.
-J O
I
SCENON 3 SCETION 7 SCETION 7
OD rn
Q
SCERON 2 SCETION 6 SCETION 6 O Z cyj IQ
W w K g @ 0
SCETION 1 SCETION 5 SCETION 5 a'0 0` O
0WN
4 SECTION DOOR SCETION 4 SCETION 4 O. m
HEIGHT RANGE 6'-6" TO 7'-0" G F I
(3) U-BARS SCETION 3 SCETION 3 0 U tl1 M
SCETION 2 SCETION 2 O, K 0
0ILa<
SCETION 5 SCETION 5 SCETION 1 SCETION 1 0 0 L
0 n
Q w M L
SCETION 4 SCETION 4 8 SECTION DOOR 8 SECTION DOOZ 0
0 - 0
HEIGHT RANGE 12'-6" TO 13'-3° HEIGHT RANGE 13'-6° TO 14'-0" J O N Q
SCETION 3 SCETION 3 (5) U-BARS
(6) U-BARS Q w m r
O
SCETION 2 ESCERIJON SCETION 9
SCEnON 8
N
Q �
7 M
5 SECTION DOOR 5 SECTION DOOR scErloN 7
HEIGHT RANGE 7'-6" TO 8'-0" HEIGHT RANGE 8'-3" TO B'-9" z o
(3) U-BARS (4) U-BARS
M
SCETION 6 C p
n M L2
N
SCETION 5 w C >
w aa�
SCETION 6 SCETION 6 h 0C- S
SCETION 4 C
O �
SCETION 5 SCETION 5 U -00
SCETION 3
w 0 O
N
SCETION 4 SCETION 4 0 Z
SCETION 2 p t
SCETION 3 SCETION 3 ¢ m 0) N
SCETION 1 Q N
N
SCETION 2 SCETION 2 O
9 SECTION DOOR
SCETION i SCETON 1 HEIGHT RANGE 14'-3" TO 15'-9"
(6) U-BARS
v
6 SECTION DOOR 6 SECTION DOOR
HEIGHT RANGE 9'-0" TO 10'-3"HEIGHT RANGE 10'-6° SCETION 10
0
(4) U-BARS (5) U-BARS PROD C If REYMEDo r r N
SCETION 9 A.� sere w}tY dt c>
K z za a
SCETION a Receplxnec No 17-019-11 y � c�i u o
SCETION 7 @ age "Z. N o 0 o a
f [[ z z z
SCETION 7 �:
SCETION 6
raw
SCETION 6
O G o 0 0
N
SCETION 5
SCETION 5 ` 0 ' s J
c
SCETION 4
BA9�1
SCETION 3 SCE/N
TION 4\� p H ®07 m o
SCETION 3 ®00 OWNS®
SCETION 2 • _
j N Q
® ®. 0592 �
ti a n
SCETION 1 SCETION 2 e e e o 0
SCETION 1 m m O
7 SECTION DOOOF
R .
HEIGHT RANGE 10'-9" TO 12'-3° ® ®�°• �Q ` dfOWin9 n0.
(5) U-BARS 10 SECTION DOOR c t. 5c7[ �a> �I®R\®�°°
HEIGHT )RANGEE 16'-0" ,/��B�j�®NAL
,. X 2-1/4" X 3/4" X 2"
�ALV. STEEL U.BAR REINFORCING TRUSS
It BOTTOM OF PANEL TRUSS FASTENED TO
VERTICAL INTERMEDIATE STILES W/ TWO
#14 X 5/8" S.M.S. AND TO END STILE
W/ FOUR #14 X 3/4" SELF DRILLING S.
1ST SECTION (BOTTOM)
REINFORCING
STEEL TRACK BRACKET FASTENED
TO WOOD JAMB WITH
5/16" X 1-5/8" LAG SCREW
(FULLY THREADED)
HEX WASHER HEAD TYPE A
SOUTHERN PINE
0.55 S.G.
MIN.
1.9" X 2.19" X 3.3" X .090"
STEEL TRACK BRACKETS
SEE SHEET 3 FOR SPACING
STEEL TRACK
14 GA. X 2-1/8" X 1" (STANDARD)
12 GA. X 3-5/16" X 1-1/2" (OPTIONAL)
FASTENED TO TRACK PLATES
W/ 1/4-20 X 5/8" TRUSS HD.
SLOTTED M.S. & LOCK NUT
1/2" X 1-3/4" X 16 GA.
OPEN TUBE
® TOP & BOTTOM
OF EACH PANEL
16 GA. X 2-1/4" X 3/4" X 2"
GALV. STEEL U.BAR REINFORCING TRUSS
TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES
W/ TWO # 14 X 5/8" S.M.S. AND TO END STILE
W/ FOUR # 14 X 3/4" SELF DRILLING SCR.
INTERMEDIATE SECTIONS
REINFORCING
OPTIONAL STOP MOULDING
BY DOOR INSTALLER
#14 X 5/8" SMS
6 PER HINGE
USE REINFORCING 'U' BAR AT
TOP SECTION ONLY AT
FOUR SECTION DOORS
24 GA. STEEL PANEL
FLAPS BENT OVER PANEL °
o °
1
I °
1/2" PUNCHED HOLES
® 4" O.C.
0.�
16 GA. X 2-1/4" X 3/4" X 2"
GALV. STEEL U.BAR REINFORCING TRUSS
TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES
W/ TWO # 14 X 5/8" S.M.S. AND TO END STILE
W/ FOUR # 14 X 3/4" SELS DRILLING SCR-
1ST
CR.
TOP SECTION
1/2" X 1-3/4" X .058" FORMED STEEL
GLUED TO PANEL AND SECURED TO
END STILE WITH (4) 3/16" POP RIVETS
1-7/8" X 2-5/8" X .049" STEEL
[CENTER STILE, GLUED AND RIVETED
TO PANEL W/ (4) 3/16" RIVETS POP RIVETS
# 14 X 5/8" S.M.S.
r 4/ HINGE
7-1/2" X .050' INTERIOR SIDE
GALV. STEEL
CENTER HINGE
7/8" PUSHNUT
INSTALLED ON ROLLER SHAFT
SECTION B—B
3/4" X 2" X 2-1/2" X .049" STEEL
END STILE, CONNECT TO PANELS WITH
FLAPS AND (5) OR (6) 3/16" ALUM RIVETS
SEE DETAIL ABOVE
EDGE
DISTANCE EDGE7
7-1/2" X .071"J V \
END ROLLER HINGE
1.82" DIA. X .50" STEEL ROLLERS (STD.)
1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL)
2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL)
2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL)
WITH 5" STEM
jQ� l
3/16" POP RIVETS J Ir
AT 4" O.C.
(6) FOR 21" STILES
(5) FOR 18" STILES
STILE
SOLID BRASS DOOR VIEWER
BY 'SCHLAGE SECURITY HARDWARE'
INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE
POSITIONED AT EYE LEVEL
as cmoclp
bolding Code !! //,� p
Acceptance No
el P Date '2- O
3/8" POWER -BOLT BY 'POWERS' (( y
2" MIN. EMBED INTO CONC.
2" MIN. EDGE DIST. q;g,ie✓ i pgq
ONE PER BRACKET
SEE SHEET 3 FOR BRACKET SPACING
1/4-20 SS BOLT
& NUT
(a *mw
Z ti
0 z m
M N
Q N
d QiN
�.Oo`m
d to N
IQu F
0 mm
vows,
0¢z�oo
Da04A
O NoN(P
Q W j LL N
ZUl -O
j
Q W 0 5 W
ct! N
� r
W N
I
N
Q �
� M
J N
O U 00
M
c o
w — I) k
v 0 LT
�aLl
o 00 N m
W O ro c o
O U Q) 0 N
W 0 2i O
0 Z N
Ln 0 0
m rn N m
N 04 2
mIr,Ir,I.
m
I
M p
N -a.
O I �
n a
o
drawing no
98-05
POP RIVETS
X 5-1/2" X 3" X .104"
GALV.S
GALV. STEEL
TOP ROLLER BRACKET ON EACH SIDE
FASTENED W/ (6) # 14 X 5/8" S.M.S.
.090 THK. GALV. STEEL ADJUSTABLE
SLIDE FASTENED TO BRACKET
/W/ 5/16-18 X 3/4" HEX HEAD
M. SCREWS & NUTS.
TOP BRACKET
(STANDARD) TOP BRACKET
(OPTIONAL)
LOW HEADROOM DOOR
5/16" X 1-5/8" LAG SCREWS INTO WOOD OR
5/16" SLEEVE ANCHORS
WITH 1-1/4" EMBED INTO MASONRY
3 PER BRACKET
2-1/2" X 4-1/4" X 13 GA. STEEL PLATES
WELDED TO 1-1/2" X 1-1/2" X 14 GA. ANGLE
FASTENED TO TRACK
WITH (4) 1/4-20 SS. BOLT & NUTS
HORIZONTAL REINFORCEMENT \
1/2" X 1-3/4" X .058" FORMED STEEL
GLUED TO PANEL AND FASTENED TO
VERTICAL STILES WITH 2" X 5-1/2" X .104"
(2) 3/16" POP RIVETS GALV. STEEL
FASTENED W/ (4) # 14 X 5/8" S.M.S.
TOP ROLLER BRACKET FOR
LOW HEADROOM DOOR OPTION
HORIZONTAL REINFORCEMENT
1/2" X 1-3/4" X .058" FORMED STEEL
GLUED TO PANEL AND FASTENED TO
VERTICAL STILES WITH
(2) 3/16" POP RIVETS
6" MEETING RIB
1.82" DIA. X .50" STEEL ROLLERS
W/ .44 DIA. X 5" STEM
HORIZ. TRACK SUPPORT,
CENTER SUPPORT READ. ON DOORS
EXREEDING 8 FT. IN HEIGHT
II
II II A --�
II A—J
HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12"
GA. GALV. STEEL TRACK
1-1/2" X 1/2" X 1/8" HORIZ. ANGLE
FOR DOOR HEIGHTS UPTO 7 FT.
WITHOUT INSULATION OR WINDOWS,
2" X 2" X 1/8" HORIZ. ANGLE
FOR DOOR HEIGHTS ABOVE 7 FT. OR
DOORS WITH INSULATION OR WINDOWS
SPOT WELDED TO HORIZ. TRACK
WITH TWO WELDS AT 1-1/2" APART
FIRST AT 3" O.C., REST AT 9" O.C.
CONNECTED TO FLAG BRACKET ANGLE
W/ 3/8-16 X 3/4" BOLT & NUT
AND TO SPRING SHAFT GUIDE WITH
(2) 1/4-20 X 5/8" BOLT & NUT
VERTICAL TRACK
2-1/8" X 1" X .080"
SECTION A—A
DOOR * SECTION HEIGHTS BRACKET PLACEMENTS
HEIGHT 1ST 2ND
3RD
4TH 5TH Bt B2 B3 84
B5
E36
B7 B8
6'-0" 18" 18"
18"
18" N/A 1" TO 2" 11-3/4" 23" 34"
45"
56"
67" —
6'-6" 21" 18"
18"
21" N/A 1" TO 2" 11-3/4" 23" 34"
45"
56"
67" —
7'-0" 21" 21"
21"
21" N/A 1" TO 2" 11-3/4" 23" 34"
45"
56"
67" —
7'-6" 18" 18"
18„
18" 1B" 1" TO 2" 11-3/4" 23" 34"
45"
56"
67" 78-1/4"
8'-0" 21„ 18"
18"
18" 21" 1" TO 2" 11-3/4" 23„ 34„
45"
56"
67" 78-1/4"
'—SECTIONS ARE NUMBERED STARTING AT THE BOTTOM
FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C.
Z
W
OPTIONAL INSULATIONS: p m 1.9" X 2.19" X 3.3" X .090"
BY 'DYPLAST PRODUCTS LLC' STEEL TRACK BRACKETS
ISO -25 POLY—ISOCYANURATE r 2-3/16" HIGH
DENSITY = 2.0 PCF m CONNECTED TO TRACK WITH
N.O.A. #16-1108.04 ) 1/4" BOLTS & NUTS.
OR
BY 'CELLOFOAM NORTH AMERICA' m
DENSITY = 1.03 PCF
N.O.A. #15-1203.04
OR m
BY 'INSULFOAM LLC'
DENSITY = 0.92 PCF
N.O.A. #17-0221.06 m
O 14 GA. GALV. STEEL m
ROLLER HINGES FASTENED N
W/ (6) # 14 X 5/8" SMS m
¢7
MIN. .024" ROLL FORMED STEEL PANEL
DRAWING QUALITY G-40
MIN. YIELD STRENGTH = 39 KSI
WITH PRIMER AND BAKED—ON
POLYSTER PAINTED TOP COAT TRACK CONFIGURATION
w APPLIED TO BOTH SIDES OF STEEL
z
a II II
N
my"U
Z W
m
0 Z N
W Z
QIL I
00 NSM
O. N
MLu
0 ~
08
N r
0 G ui ei
0'o -M o
0 IL Q< .i
0 0 �
0
Q LU �
{LZN -o
f of M
f5 N
Q W m F r
12 GA. GALV. STEEL VERTICAL LIFT HIGH LIFT STANDARD LIFT LOW HEADROOM
BO (4) # 14 X 5DOUBLE TRACK o
FAS SMS
r
AVAILABLE TRACK OPTIONS
BOTTOM BRACKET FASTENED 0
V`011811111g��'Z®
�®GBPdSlc
® o
O BOTTOM SEAL OPTIONS m .7 592
SEE SHEET 5
®®'•, V E®fF & drawing no.
SECTION A -A Out-. 0, € ®°o��s�°° fit °®�°°° �0�� 98-05
SOF REINFORCING TRUSSES € `7i'�e�ft\9QLt\% \ sheet 4 of 6
OPTION 'A'
OPTION 'B'
WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.)
THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT
TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN
WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE.
FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE
VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION.
5/16" X 1 -6/8 -
LAG SCREWS
AT 11" O.C.
\e
WOOD BUCK CONNECTION TO MASONRY
PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 1
GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH
1/4" ULTRACON BY 'ELCO' WITH SPACING OF
12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 1
9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
2-1/2" MIN. EDGE DISTANCE t�
1/4" TAPPER BY 'POWERS' WITH SPACING OF
8" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED
9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
3" MIN. EDGE DISTANCE _
3/8" CONFLEX BY 'ELCO' OR
3/8" LOT BY 'I1W' WITH SPACING OF CONTINUOUS ANGLE TRACK
21" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED TO WOOD BUCK
3" MIN. EDGE DISTANCE
3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF
B" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST.
11" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND
2-1/2" MIN. EDGE DISTANCE
PREPARATION OF JAMBS BY OTHERS
FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY
ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED
BY DOOR SYSTEM.
FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF
RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY
BUILDING OFFICIAL UPON INSPECTION.
MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.17' X 48 PSF)/2 = 388 Lbs per Ft.
MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.17' X 70 PSF)/2 = 420.4 lbs per Ft.
1/16„ X 2-1/2"
FILLET WELDS
AT 12" O.C. MAX.
W'STRIP ADAPTER
ALUMINUM
RUBBER
STEEL STRUCTURE BY OTHERS
MUST SUPPORT THE LOADS IMPOSED
BY DOOR SYSTEM
III
REVERSE TRACK
TO STEEL
050
224 r .534
5/16" DIA. BOLTS
WITH WASHER & NUT
AT 12" O.C. MAX.
REINFORCEMENT
1/2" X 1-3/4" X .058"
FORMED STEEL
#8 X 1"
SELF DRILLING SCREWS
OR
3/16" 'RIVEX' STEEL RIVETS
MULTIGRIP W/ DOME HEAD
AT 48" O.C.
K(D
W'STRIP ADAPTER
STEEL
DO .040
700
.348
1.7904
BOTTOM SEAL OPTIONS
W'STRIPPING
i
{" R
ANCHOR SPACING
ANCHORS
Lu�L
EMBED
I SPACING
#8 X 1"
3/8" HLC SLEEVE BY 'HILTI'
CONC.
1-1/4"
8"
2"
DIST'
FILLED BLOCK
2"
SELF DRILLING SCREWS
3-3/4"
z
CONC.
1-1/2" MIN.
8"
3"
3/8" POWER -BOLT BY 'POWERS'
CONC.
OR
8"
2"
3/8" SLEEVE -ALL BY 'SIMPSONS'
GE DIST.
1-t 2"
1 8"
3"
3/16" 'RIVEX' STEEL RIVETSMULTIGRIP
At_o
A��suoo
W/ DOME HEAD
3
w
AT 48" O.C.
REINFORCEMENT
1/2" X 1-3/4" X .058"
FORMED STEEL
2BY
1/4" DIA. LAG SCREWS
2BY
1/4" DIA. LAG SCREWS
WOOD B�
AT 6" FROM ENDS
WOOD
AT 6" FROM ENDS
i AND 11" D.C. MAX.
i
AND 11" O.C. MAX.
OPTION 'A'
OPTION 'B'
WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.)
THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT
TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN
WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE.
FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE
VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION.
5/16" X 1 -6/8 -
LAG SCREWS
AT 11" O.C.
\e
WOOD BUCK CONNECTION TO MASONRY
PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 1
GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH
1/4" ULTRACON BY 'ELCO' WITH SPACING OF
12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 1
9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
2-1/2" MIN. EDGE DISTANCE t�
1/4" TAPPER BY 'POWERS' WITH SPACING OF
8" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED
9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
3" MIN. EDGE DISTANCE _
3/8" CONFLEX BY 'ELCO' OR
3/8" LOT BY 'I1W' WITH SPACING OF CONTINUOUS ANGLE TRACK
21" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED TO WOOD BUCK
3" MIN. EDGE DISTANCE
3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF
B" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST.
11" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND
2-1/2" MIN. EDGE DISTANCE
PREPARATION OF JAMBS BY OTHERS
FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY
ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED
BY DOOR SYSTEM.
FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF
RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY
BUILDING OFFICIAL UPON INSPECTION.
MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.17' X 48 PSF)/2 = 388 Lbs per Ft.
MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.17' X 70 PSF)/2 = 420.4 lbs per Ft.
1/16„ X 2-1/2"
FILLET WELDS
AT 12" O.C. MAX.
W'STRIP ADAPTER
ALUMINUM
RUBBER
STEEL STRUCTURE BY OTHERS
MUST SUPPORT THE LOADS IMPOSED
BY DOOR SYSTEM
III
REVERSE TRACK
TO STEEL
050
224 r .534
5/16" DIA. BOLTS
WITH WASHER & NUT
AT 12" O.C. MAX.
REINFORCEMENT
1/2" X 1-3/4" X .058"
FORMED STEEL
#8 X 1"
SELF DRILLING SCREWS
OR
3/16" 'RIVEX' STEEL RIVETS
MULTIGRIP W/ DOME HEAD
AT 48" O.C.
K(D
W'STRIP ADAPTER
STEEL
DO .040
700
.348
1.7904
BOTTOM SEAL OPTIONS
W'STRIPPING
i
{" R
ANCHOR SPACING
ANCHORS
STRUCTURE
EMBED
I SPACING
EDGE DIST.
3/8" HLC SLEEVE BY 'HILTI'
CONC.
1-1/4"
8"
2"
3/8- CONFLEX BY 'ELCO'
FILLED BLOCK
2"
8"
3-3/4"
3 8" DYNABOLT BY 'TTW'
CONC.
1-1/2"
8"
3"
3/8" POWER -BOLT BY 'POWERS'
CONC.
2"
8"
2"
3/8" SLEEVE -ALL BY 'SIMPSONS'
CONC.
1-t 2"
1 8"
3"
CONCRETE Vc = 3000 PSI MIN.
C-90 GROUT FILLED BLOCK Vm = 2000 PSI MIN.
1-1/4" X 2-1/2" X 14 GA
CONT. STEEL ANGLE
12 GA. GALV. STEEL
FLAT BRACKETS t3" LONG
AT 12" O.C. IN DOOR OPNG.
AT 18" O.C. ABOVE DOOR OPNG.
CONNECTED TO CONT. ANGLE
W/ (3) SPOT WELDS AT EACH SIDE
ALTERNATE TRACK INSTALLATION
EDGE DIST.
1-1/2"
2-1/8" X 1" X 14 GA.
GALV. STEEL TRACK
FASTENED TO TRACK PLATES
W/ (2) 1/4-20X5/8" TRUSS HD.
SLOTTED M.S. & LOCK NUT
CONTINUOUS ANGLE TRACK
TO CONCRETE AND FILLED BLOCK
F — 011 �9 io
r •
m
.70592
a
a= N
o r
W N
co °'
I
� M
J N
z
0 o V 00 n
w — 7 x
N 17 LL
N
W 0 Q
n a-,
W 0 00
O
o U 0) 0 N
W L O N
J p z N
L 0 0
d DO 0) vs
N <
m
m
r� a
o I ¢
v m a n
O V y
drawing no.
98-05
sheet 5 of
DOOR PANEL
24 GA. (.024) STEEL MIN.
7/16" DIA. WASHER
R PANEL
GA. (.024) STEEL MIN.
21 3/4"
MAX.
�_#8 X 3/4" SMS
I
II I ® 3/8" FROM ENDS
O
1
w
I II AND 7" O.C. MAX.
a
I
ILII
'
o N Jo
I.
(4) #8 X 3/4" SMS
0
0 1-3/8" FROM ENDS
IIII
I AND 6-1/2" O.C. MAX.
I:
-
IIII
.175 X .062 DEEP
I I
Illj
GROOVE
IIII
1/4" POLYCARBONATE LEXAN
BY 'SABIC INNOVATIVE PLASTICS'
�I!I
NOA #15-0915.08
�
ILII
� O
a Ld
o w
� X
jljl
o w
I.1
IIII
III
Ili!
.175 X .062 DEEP
GROOVE
III
II
Ijl
I i (4) #8 X 3/4" SMS
® 1-3/8" FROM ENDS
I'
j j j
I AND 6-1/2" O.C. MAX.
O
1
.
C
1 I
#8 X 3/4" SMS
® 3/8" FROM ENDS
AND 7" O.C. MAX.
7/16" DIA. WASHER
R PANEL
GA. (.024) STEEL MIN.
21 3/4"
* PLASTIC COMPLIES WITH
CHAPTER 26 OF FBC
SEE EVIDENCE PAGE
Kim
—.500 250
4.
o
I
0� °
c4i.� n w
Q
2 ID K
W N
1.765 1.725 Q S
QW N
1,144 d > N
0CF
o�Nn
LLL
M
,176 ,800 Q S 0 0 00
* EXTERIOR FRAME * INTERIOR FRAME C R
O
RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION Q w LL m
LL Z N - o
M
J z M a w
w 0) i
i
i
#8 X 3/4" SMS
® 3/8" FROM ENDS
AND 4-1/2' O.C. MAX.
DOOR PANEL
24 GA. (.024) STEEL MIN.
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION
.175 X .062 DEEP
15/16" MIN.
WINDOW WIDTH
EXTERIOR
D.L. OPG.
6..t, 6y 2•064
�i
�. • VlCER9y�"°•.°
No 70592
YE OF ��°
MAX.
WDW. WIDI
w
18 1/8"
a
x o
MAX.
o N Jo
D.L.O.
3
0
A
* PLASTIC COMPLIES WITH
CHAPTER 26 OF FBC
SEE EVIDENCE PAGE
Kim
—.500 250
4.
o
I
0� °
c4i.� n w
Q
2 ID K
W N
1.765 1.725 Q S
QW N
1,144 d > N
0CF
o�Nn
LLL
M
,176 ,800 Q S 0 0 00
* EXTERIOR FRAME * INTERIOR FRAME C R
O
RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION Q w LL m
LL Z N - o
M
J z M a w
w 0) i
i
i
#8 X 3/4" SMS
® 3/8" FROM ENDS
AND 4-1/2' O.C. MAX.
DOOR PANEL
24 GA. (.024) STEEL MIN.
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION
.175 X .062 DEEP
15/16" MIN.
WINDOW WIDTH
EXTERIOR
D.L. OPG.
6..t, 6y 2•064
�i
�. • VlCER9y�"°•.°
No 70592