Loading...
HomeMy WebLinkAbout17101811 - 16' NOA 48-52MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy DAB Door Company, Inc. 12195 NW 98" Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Hurricane Master Model 824/811 Steel Sectional Garage Door up to 16'-2" w/ Window Lite Option (DP +48.0,-52.0 PSF) APPROVAL DOCUMENT: Drawing No. 98-05 Rev M, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 02/23/1998 and last revised on OCT 03, 2017, sheets 1 through 6 of 6, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 15-0302.01 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. MIAMI•DADE COUNTY NOA No. 17-1018.11 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 Page 1 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED Evidence submitted in previous files A. DRAWINGS 1. Drawing No. 98-05, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 02/23/1998, with last revision L dated 03/05/2015, sheets 1 through 6 of 6, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 11-0414.13" 1. Test Report on Uniform Static Air Pressure Test, Loading and Forced Entry Test per FBC, TAS 202-94, of "DAB 824 Sectional Residential Garage Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI-07-4267, dated 06/29/2007, signed and sealed by Candido F. Font, P.E. 2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing Inc., Report No. HETI-11-3206, dated 02/10/2011, signed and sealed by Candido F. Font, P.E. 3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI-11-T101, dated 01/29/2011, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 05-0217.02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional Residential Door with Windows" prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI 03-1328, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, PE. 5. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door" prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI 03-1329, dated 07/15/2003 signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test Report on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)" prepared by Hurricane Engineering & Testing Inc, Test Report No. HETI 03-T078, dated 10/31/2003, signed and sealed by Rafael E. Droz-Seda, P.E. "Submitted under NOA # 03-0210.04" 7. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. C. CALCULATIONS "Submitted under NOA # 14-0814.08" 1. Anchor verification calculations prepared by AI-Farooq Corporation, dated 09/22/2014 and 07/24/2014, signed and sealed by Javad Ahmad, P.E. I haq 1. Chanda, P.E. Product Control Examiner NOA No. 17-1018.11 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E-1 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (Cont.) "Submitted under NOA # 09-0128.01" 2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 04/05/2011, signed and sealed by Javad Ahmad, P.E. "Submitted under NOA # 09-0128.01" 3. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 12/18/2008, signed and sealed by Humayoun Farooq, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0717.01, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their Dyplast ISO -C I Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 10-1129.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA # 05-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by I. Ghia, P.E. 8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of "BEHAU non -foam PVC extrusion material', prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by L L. Doldan, P.E. F. STATEMENTS "Submitted under NOA # 14-0814.08" 1. Statement letter of code conformance to the 5' edition (2014) FBC and no financial interest issued by Al-Farooq Corporation, dated 05/13/2014, signed and sealed by Javad Ahmad, P.E. �- Ish q I. Chanda, P.E. Product Control Examiner NOA No. 17-1018.11 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E -2 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUB 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. 98-05 Rev M, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 02/23/1998 and last revised on OCT 03, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. Note: This revision consist of editorial changes to comply with FBC 2017. B. CALCULATIONS 1. None C. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). D. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0221.06, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, expiring on 11/29/2022. 2. Notice of Acceptance No. 16-1108.04, issued to Dyplast Products, LLC, for their Dyplast ISO -C1 Polyisocyanurate Insulation, expiring on 01/11/2022. 3. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, expiring on 02/24/2021. 4. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, expiring on 07/17/2018. E. STATEMENTS 1. Statement letter of conformance to FBC 2014 (51h Edition) and FBC 2017 (611 Edition), prepared by Al Farooq Corporation, dated 10/05/17, signed and sealed by Javad Ahmad, P.E. F. OTHER 1. This NOA revises NOA #15-0302.01, expiring 07/21/20 Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 17-1018.11 Expiration Date: July 21, 2020 Approval Date: December 14, 2017 E -3 IO 7-1/2" X 2-1/4" X 18 GA. GALV. STEEL CENTER HINGE O W/ (4) #14 X 5/8" SMS WITHOUT DELRON SLEEVE (STD.) O 7-1/2" X 3" X .071" GALV. STEEL END ROLLER HINGE I W/ (6) #14 X 5/8" SMS WITHOUT DELRON SLEEVE (STD.) WITH DELRON SLEEVE (OPTIONAL) TOP FIXTURE 5-1/2" X 2-3/4" X 0.1" NUT STEEL PLATE WITH ONE 5/16-18 MS W/ NUT �FASTENED TO END STILE WITH (6) S14 X 3/4" SELF DRILLING SCREWS SEE SHEET 4 FOR TOP BRACKET OPTIONS CFNTFR CTII FC O `y , 7-1/2" X 2-1/4" X .071" \ O+ GALV. STEEL CENTER HINGE - O W/ (4) #14 X 5/8" SMS LOCK WITH DELRON SLEEVE (OPTIONAL) 2/ DOOR \ a\ CENTER HINGE 1" W X .15 THK. LATCH STANDARD LOCK r \� SPRING LOADED SLIDE BOLT (BOTH SIDES FASTENED W/ (4) #14 X 1/2" S.M.S. `�\ B 5/8" MIN. LOCK ENGAGEMENT CONFORMS TO SECTION 1008 REGARDING GARAGE DOORS ` .158 DIA. GALV. AIRCRAFT TYPE CABLE & NICO -PRESS SLEEVE W/ MIN. 5 TO 1 SAFETY FACTOR 7" X 3" X 0.1" STEEL PLATE WITH (4) #14 X 3/4" SELF DRILLING SCREWS i o m I L O BRACKET STD. LIFT DOOR DOOR HEIGHT CONSISTS OF TOTAL # OF 'U' BARS AT EACH DOOR 6'-6" 2 SECTIONS 18" 2 SECTIONS 21" 3 6'-9" 1 SECTION 18" 3 SECTIONS 21" 7' 4 SECTIONS 21" - 7'-3" - - 7'-6" 5 SECTIONS 18" - 7'-9" 4 SECTIONS 18" 1 SECTION 21" 8' 3 SECTIONS 18' 2 SECTIONS 21" 8'-3' 12 SECTIONS 18" 3 SECTIONS 21" 4 8'-6" 1 SECTION 18" 4 SECTIONS 21" 8'-9" 5 SECTIONS 21" - 9' 6 SECTIONS 18" - 9'-3" 5 SECTIONS 18" 1 SECTION 21" 9'-6" 4 SECTIONS 18" 2 SECTIONS 21" 9'-9" 3 SECTIONS 18" 3 SECTIONS 21" 10' 2 SECTIONS 18" 4 SECTIONS 21' 10'-3" 1 SECTION 18" 5 SECTIONS 21" 10'-6" 6 SECTIONS 21" - 10'-9" 6 SECTIONS 18".1 SECTION 21" 5 11' 5 SECTIONS 18" 2 SECTIONS 21" 11'-3" 4 SECTIONS 18" 3 SECTIONS 21" 11'-6" 3 SECTIONS 18" 4 SECTIONS 21" 11'-9" 2 SECTIONS 18" 5 SECTIONS 21" 12' 1 SECTIONS 18" 6 SECTIONS 21' 12'-3" 7 SECTIONS 21" - 12'-6" 6 SECTIONS 18" 2 SECTIONS 21" 12'-9" 5 SECTIONS 18" 3 SECTIONS 21" 13' 4 SECTIONS 18" 4 SECTIONS 21" 13'-3" 3 SECTIONS 18".5 SECTIONS 21" 13'-6" 2 SECTIONS 18" 6 SECTIONS 21" 6 13'-9" 1 SECTION 18" 7 SECTIONS 21" 14' 8 SECTIONS 21" - 14'-3" 6 SECTIONS 18" 3 SECTIONS 21" 14'-6" 5 SECTIONS 18" 4 SECTIONS 21" 14'-9" 4 SECTIONS 18" 5 SECTIONS 21" 15' 3 SECTIONS 18" 6 SECTIONS 21" 15'-3" 2 SECTIONS 18" 7 SECTIONS 21" 15'-6" 1 SECTION 18" 8 SECTIONS 21' 15'-9" 9 SECTIONS 21" - 16' 6 SECTIONS 18-14 SECTIONS 21" VA0 O ° N BRACKET LOW HEADROOM DOOR OPTION 7-7/8" X 3-1/8" X .010" \ STEEL PLATE WITH (4) #14 X 3/4" SDS CENTER STILE IF OPTIONAL DOOR VIEWER TO BE INSTALLED AT ANY CENTER STIL� 10 -Z DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT INSIDE ELEVATION BUILDING CODE, TAS -202, TAS -201 & TAS -203 FOR HVHZ AND RAISED PANEL EMBOSSED DOOR ASTM E1886-05/ASTM E1996-09. END STILE LOCK BAR GUIDES ON END STILE ffH (4) #14 X 5/8" SMS JIWNSTALLED X .6W LOCK BAR GES IN TRACK ON EACH SIDE OF DOOR CENTER STILES OUTSIDE KEYED LOCK OPTIONAL LOCK BAR LOCKING SHOWN ALTERNATE TO SPRING LOADED SLIDE BOLT LOCKS SHOWN ABOVE 8'-0" TO W-10" DAB DOORS INC. Hurricane Master® Model 824/811 Max. Size 16'-2" X 16'-0" High With Window Lite Option DESIGN PRESSURE RATING = + 48.0 PSF - 52.0 PSF SCHEDULE 'A' CENTER STILES CONFIGURATION DOOR WIDTHS # OF CENTER STILES B'-0" TO 9'-10" 2 10'-0" TO 11'-10" 2 12'-0" TO 13'-10" 3 14'-0" TO 15'-10" 4 15'-11" TO 16'-2" 5 1 110711 17t], 10 -Z DOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT INSIDE ELEVATION BUILDING CODE, TAS -202, TAS -201 & TAS -203 FOR HVHZ AND RAISED PANEL EMBOSSED DOOR ASTM E1886-05/ASTM E1996-09. END STILE LOCK BAR GUIDES ON END STILE ffH (4) #14 X 5/8" SMS JIWNSTALLED X .6W LOCK BAR GES IN TRACK ON EACH SIDE OF DOOR CENTER STILES OUTSIDE KEYED LOCK OPTIONAL LOCK BAR LOCKING SHOWN ALTERNATE TO SPRING LOADED SLIDE BOLT LOCKS SHOWN ABOVE 8'-0" TO W-10" DAB DOORS INC. Hurricane Master® Model 824/811 Max. Size 16'-2" X 16'-0" High With Window Lite Option DESIGN PRESSURE RATING = + 48.0 PSF - 52.0 PSF SCHEDULE 'A' CENTER STILES CONFIGURATION DOOR WIDTHS # OF CENTER STILES B'-0" TO 9'-10" 2 10'-0" TO 11'-10" 2 12'-0" TO 13'-10" 3 14'-0" TO 15'-10" 4 15'-11" TO 16'-2" 5 GENERAL NOTES 1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. 4. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS 5. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 6. MANUFACTURER'S LABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION IN ACCORDANCE WITH SECTION 1709.9.3 OF FLORIDA BUILDING CODE. LABELING TO COMPLY WITH SECTION 1709.9.2. 111119t to%mu Zn m Z M W F W � CL aCL $« 0 N 0 OO d`a ��W N 0 U N O'eIL� 0 IL 0 0��ix� 0 N a W jLL 1LW 'a m 0W¢ w a ZME r 14 X 3/4' SELF DRILLING SCREWS o ✓ siitRe MAY BE USED IN LIEU OF #14 X 5/8" SMS o F cNoPT-(D/ °) 10'-0" TO 11'-10"_ 14'-0" TO 15'-10" _ m 0582 Diate 6 ''.O DOOR WIDTHS DOOR WIDTHS 0 e ®®�•, S4 T€11 4,t < ['drawing7no. -�c®�a®�..,98— REFEU TEAR PLAC EM 12 DOOR WIDTHS -10" ( `o- 15'DOOR WIDTHS 2 °°°�11�\ \``` sheet 1 of 6 SCERON 4 SCETION 8 SCETION 8 L7U. -J O I SCENON 3 SCETION 7 SCETION 7 OD rn Q SCERON 2 SCETION 6 SCETION 6 O Z cyj IQ W w K g @ 0 SCETION 1 SCETION 5 SCETION 5 a'0 0` O 0WN 4 SECTION DOOR SCETION 4 SCETION 4 O. m HEIGHT RANGE 6'-6" TO 7'-0" G F I (3) U-BARS SCETION 3 SCETION 3 0 U tl1 M SCETION 2 SCETION 2 O, K 0 0ILa< SCETION 5 SCETION 5 SCETION 1 SCETION 1 0 0 L 0 n Q w M L SCETION 4 SCETION 4 8 SECTION DOOR 8 SECTION DOOZ 0 0 - 0 HEIGHT RANGE 12'-6" TO 13'-3° HEIGHT RANGE 13'-6° TO 14'-0" J O N Q SCETION 3 SCETION 3 (5) U-BARS (6) U-BARS Q w m r O SCETION 2 ESCERIJON SCETION 9 SCEnON 8 N Q � 7 M 5 SECTION DOOR 5 SECTION DOOR scErloN 7 HEIGHT RANGE 7'-6" TO 8'-0" HEIGHT RANGE 8'-3" TO B'-9" z o (3) U-BARS (4) U-BARS M SCETION 6 C p n M L2 N SCETION 5 w C > w aa� SCETION 6 SCETION 6 h 0C- S SCETION 4 C O � SCETION 5 SCETION 5 U -00 SCETION 3 w 0 O N SCETION 4 SCETION 4 0 Z SCETION 2 p t SCETION 3 SCETION 3 ¢ m 0) N SCETION 1 Q N N SCETION 2 SCETION 2 O 9 SECTION DOOR SCETION i SCETON 1 HEIGHT RANGE 14'-3" TO 15'-9" (6) U-BARS v 6 SECTION DOOR 6 SECTION DOOR HEIGHT RANGE 9'-0" TO 10'-3"HEIGHT RANGE 10'-6° SCETION 10 0 (4) U-BARS (5) U-BARS PROD C If REYMEDo r r N SCETION 9 A.� sere w}tY dt c> K z za a SCETION a Receplxnec No 17-019-11 y � c�i u o SCETION 7 @ age "Z. N o 0 o a f [[ z z z SCETION 7 �: SCETION 6 raw SCETION 6 O G o 0 0 N SCETION 5 SCETION 5 ` 0 ' s J c SCETION 4 BA9�1 SCETION 3 SCE/N TION 4\� p H ®07 m o SCETION 3 ®00 OWNS® SCETION 2 • _ j N Q ® ®. 0592 � ti a n SCETION 1 SCETION 2 e e e o 0 SCETION 1 m m O 7 SECTION DOOOF R . HEIGHT RANGE 10'-9" TO 12'-3° ® ®�°• �Q ` dfOWin9 n0. (5) U-BARS 10 SECTION DOOR c t. 5c7[ �a> �I®R\®�°° HEIGHT )RANGEE 16'-0" ,/��B�j�®NAL ,. X 2-1/4" X 3/4" X 2" �ALV. STEEL U.BAR REINFORCING TRUSS It BOTTOM OF PANEL TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO #14 X 5/8" S.M.S. AND TO END STILE W/ FOUR #14 X 3/4" SELF DRILLING S. 1ST SECTION (BOTTOM) REINFORCING STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH 5/16" X 1-5/8" LAG SCREW (FULLY THREADED) HEX WASHER HEAD TYPE A SOUTHERN PINE 0.55 S.G. MIN. 1.9" X 2.19" X 3.3" X .090" STEEL TRACK BRACKETS SEE SHEET 3 FOR SPACING STEEL TRACK 14 GA. X 2-1/8" X 1" (STANDARD) 12 GA. X 3-5/16" X 1-1/2" (OPTIONAL) FASTENED TO TRACK PLATES W/ 1/4-20 X 5/8" TRUSS HD. SLOTTED M.S. & LOCK NUT 1/2" X 1-3/4" X 16 GA. OPEN TUBE ® TOP & BOTTOM OF EACH PANEL 16 GA. X 2-1/4" X 3/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO # 14 X 5/8" S.M.S. AND TO END STILE W/ FOUR # 14 X 3/4" SELF DRILLING SCR. INTERMEDIATE SECTIONS REINFORCING OPTIONAL STOP MOULDING BY DOOR INSTALLER #14 X 5/8" SMS 6 PER HINGE USE REINFORCING 'U' BAR AT TOP SECTION ONLY AT FOUR SECTION DOORS 24 GA. STEEL PANEL FLAPS BENT OVER PANEL ° o ° 1 I ° 1/2" PUNCHED HOLES ® 4" O.C. 0.� 16 GA. X 2-1/4" X 3/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO # 14 X 5/8" S.M.S. AND TO END STILE W/ FOUR # 14 X 3/4" SELS DRILLING SCR- 1ST CR. TOP SECTION 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND SECURED TO END STILE WITH (4) 3/16" POP RIVETS 1-7/8" X 2-5/8" X .049" STEEL [CENTER STILE, GLUED AND RIVETED TO PANEL W/ (4) 3/16" RIVETS POP RIVETS # 14 X 5/8" S.M.S. r 4/ HINGE 7-1/2" X .050' INTERIOR SIDE GALV. STEEL CENTER HINGE 7/8" PUSHNUT INSTALLED ON ROLLER SHAFT SECTION B—B 3/4" X 2" X 2-1/2" X .049" STEEL END STILE, CONNECT TO PANELS WITH FLAPS AND (5) OR (6) 3/16" ALUM RIVETS SEE DETAIL ABOVE EDGE DISTANCE EDGE7 7-1/2" X .071"J V \ END ROLLER HINGE 1.82" DIA. X .50" STEEL ROLLERS (STD.) 1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL) 2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL) 2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL) WITH 5" STEM jQ� l 3/16" POP RIVETS J Ir AT 4" O.C. (6) FOR 21" STILES (5) FOR 18" STILES STILE SOLID BRASS DOOR VIEWER BY 'SCHLAGE SECURITY HARDWARE' INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE POSITIONED AT EYE LEVEL as cmoclp bolding Code !! //,� p Acceptance No el P Date '2- O 3/8" POWER -BOLT BY 'POWERS' (( y 2" MIN. EMBED INTO CONC. 2" MIN. EDGE DIST. q;g,ie✓ i pgq ONE PER BRACKET SEE SHEET 3 FOR BRACKET SPACING 1/4-20 SS BOLT & NUT (a *mw Z ti 0 z m M N Q N d QiN �.Oo`m d to N IQu F 0 mm vows, 0¢z�oo Da04A O NoN(P Q W j LL N ZUl -O j Q W 0 5 W ct! N � r W N I N Q � � M J N O U 00 M c o w — I) k v 0 LT �aLl o 00 N m W O ro c o O U Q) 0 N W 0 2i O 0 Z N Ln 0 0 m rn N m N 04 2 mIr,Ir,I. m I M p N -a. O I � n a o drawing no 98-05 POP RIVETS X 5-1/2" X 3" X .104" GALV.S GALV. STEEL TOP ROLLER BRACKET ON EACH SIDE FASTENED W/ (6) # 14 X 5/8" S.M.S. .090 THK. GALV. STEEL ADJUSTABLE SLIDE FASTENED TO BRACKET /W/ 5/16-18 X 3/4" HEX HEAD M. SCREWS & NUTS. TOP BRACKET (STANDARD) TOP BRACKET (OPTIONAL) LOW HEADROOM DOOR 5/16" X 1-5/8" LAG SCREWS INTO WOOD OR 5/16" SLEEVE ANCHORS WITH 1-1/4" EMBED INTO MASONRY 3 PER BRACKET 2-1/2" X 4-1/4" X 13 GA. STEEL PLATES WELDED TO 1-1/2" X 1-1/2" X 14 GA. ANGLE FASTENED TO TRACK WITH (4) 1/4-20 SS. BOLT & NUTS HORIZONTAL REINFORCEMENT \ 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH 2" X 5-1/2" X .104" (2) 3/16" POP RIVETS GALV. STEEL FASTENED W/ (4) # 14 X 5/8" S.M.S. TOP ROLLER BRACKET FOR LOW HEADROOM DOOR OPTION HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 6" MEETING RIB 1.82" DIA. X .50" STEEL ROLLERS W/ .44 DIA. X 5" STEM HORIZ. TRACK SUPPORT, CENTER SUPPORT READ. ON DOORS EXREEDING 8 FT. IN HEIGHT II II II A --� II A—J HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12" GA. GALV. STEEL TRACK 1-1/2" X 1/2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS UPTO 7 FT. WITHOUT INSULATION OR WINDOWS, 2" X 2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS ABOVE 7 FT. OR DOORS WITH INSULATION OR WINDOWS SPOT WELDED TO HORIZ. TRACK WITH TWO WELDS AT 1-1/2" APART FIRST AT 3" O.C., REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8" BOLT & NUT VERTICAL TRACK 2-1/8" X 1" X .080" SECTION A—A DOOR * SECTION HEIGHTS BRACKET PLACEMENTS HEIGHT 1ST 2ND 3RD 4TH 5TH Bt B2 B3 84 B5 E36 B7 B8 6'-0" 18" 18" 18" 18" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" — 6'-6" 21" 18" 18" 21" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" — 7'-0" 21" 21" 21" 21" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" — 7'-6" 18" 18" 18„ 18" 1B" 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" 78-1/4" 8'-0" 21„ 18" 18" 18" 21" 1" TO 2" 11-3/4" 23„ 34„ 45" 56" 67" 78-1/4" '—SECTIONS ARE NUMBERED STARTING AT THE BOTTOM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. Z W OPTIONAL INSULATIONS: p m 1.9" X 2.19" X 3.3" X .090" BY 'DYPLAST PRODUCTS LLC' STEEL TRACK BRACKETS ISO -25 POLY—ISOCYANURATE r 2-3/16" HIGH DENSITY = 2.0 PCF m CONNECTED TO TRACK WITH N.O.A. #16-1108.04 ) 1/4" BOLTS & NUTS. OR BY 'CELLOFOAM NORTH AMERICA' m DENSITY = 1.03 PCF N.O.A. #15-1203.04 OR m BY 'INSULFOAM LLC' DENSITY = 0.92 PCF N.O.A. #17-0221.06 m O 14 GA. GALV. STEEL m ROLLER HINGES FASTENED N W/ (6) # 14 X 5/8" SMS m ¢7 MIN. .024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 39 KSI WITH PRIMER AND BAKED—ON POLYSTER PAINTED TOP COAT TRACK CONFIGURATION w APPLIED TO BOTH SIDES OF STEEL z a II II N my"U Z W m 0 Z N W Z QIL I 00 NSM O. N MLu 0 ~ 08 N r 0 G ui ei 0'o -M o 0 IL Q< .i 0 0 � 0 Q LU � {LZN -o f of M f5 N Q W m F r 12 GA. GALV. STEEL VERTICAL LIFT HIGH LIFT STANDARD LIFT LOW HEADROOM BO (4) # 14 X 5DOUBLE TRACK o FAS SMS r AVAILABLE TRACK OPTIONS BOTTOM BRACKET FASTENED 0 V`011811111g��'Z® �®GBPdSlc ® o O BOTTOM SEAL OPTIONS m .7 592 SEE SHEET 5 ®®'•, V E®fF & drawing no. SECTION A -A Out-. 0, € ®°o��s�°° fit °®�°°° �0�� 98-05 SOF REINFORCING TRUSSES € `7i'�e�ft\9QLt\% \ sheet 4 of 6 OPTION 'A' OPTION 'B' WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16" X 1 -6/8 - LAG SCREWS AT 11" O.C. \e WOOD BUCK CONNECTION TO MASONRY PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 1 GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 1 9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2" MIN. EDGE DISTANCE t� 1/4" TAPPER BY 'POWERS' WITH SPACING OF 8" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED 9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE _ 3/8" CONFLEX BY 'ELCO' OR 3/8" LOT BY 'I1W' WITH SPACING OF CONTINUOUS ANGLE TRACK 21" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED TO WOOD BUCK 3" MIN. EDGE DISTANCE 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF B" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST. 11" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE PREPARATION OF JAMBS BY OTHERS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.17' X 48 PSF)/2 = 388 Lbs per Ft. MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.17' X 70 PSF)/2 = 420.4 lbs per Ft. 1/16„ X 2-1/2" FILLET WELDS AT 12" O.C. MAX. W'STRIP ADAPTER ALUMINUM RUBBER STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM III REVERSE TRACK TO STEEL 050 224 r .534 5/16" DIA. BOLTS WITH WASHER & NUT AT 12" O.C. MAX. REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL #8 X 1" SELF DRILLING SCREWS OR 3/16" 'RIVEX' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. K(D W'STRIP ADAPTER STEEL DO .040 700 .348 1.7904 BOTTOM SEAL OPTIONS W'STRIPPING i {" R ANCHOR SPACING ANCHORS Lu�L EMBED I SPACING #8 X 1" 3/8" HLC SLEEVE BY 'HILTI' CONC. 1-1/4" 8" 2" DIST' FILLED BLOCK 2" SELF DRILLING SCREWS 3-3/4" z CONC. 1-1/2" MIN. 8" 3" 3/8" POWER -BOLT BY 'POWERS' CONC. OR 8" 2" 3/8" SLEEVE -ALL BY 'SIMPSONS' GE DIST. 1-t 2" 1 8" 3" 3/16" 'RIVEX' STEEL RIVETSMULTIGRIP At_o A��suoo W/ DOME HEAD 3 w AT 48" O.C. REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL 2BY 1/4" DIA. LAG SCREWS 2BY 1/4" DIA. LAG SCREWS WOOD B� AT 6" FROM ENDS WOOD AT 6" FROM ENDS i AND 11" D.C. MAX. i AND 11" O.C. MAX. OPTION 'A' OPTION 'B' WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16" X 1 -6/8 - LAG SCREWS AT 11" O.C. \e WOOD BUCK CONNECTION TO MASONRY PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO 1 GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4" MIN. EMBED 1 9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2" MIN. EDGE DISTANCE t� 1/4" TAPPER BY 'POWERS' WITH SPACING OF 8" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2" MIN. EMBED 9" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE _ 3/8" CONFLEX BY 'ELCO' OR 3/8" LOT BY 'I1W' WITH SPACING OF CONTINUOUS ANGLE TRACK 21" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED TO WOOD BUCK 3" MIN. EDGE DISTANCE 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF B" O.C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4" MIN. EDGE DIST. 11" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE PREPARATION OF JAMBS BY OTHERS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER JAMB = (16.17' X 48 PSF)/2 = 388 Lbs per Ft. MAXIMUM INTERIOR(-) LOAD PER JAMB = (16.17' X 70 PSF)/2 = 420.4 lbs per Ft. 1/16„ X 2-1/2" FILLET WELDS AT 12" O.C. MAX. W'STRIP ADAPTER ALUMINUM RUBBER STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM III REVERSE TRACK TO STEEL 050 224 r .534 5/16" DIA. BOLTS WITH WASHER & NUT AT 12" O.C. MAX. REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL #8 X 1" SELF DRILLING SCREWS OR 3/16" 'RIVEX' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. K(D W'STRIP ADAPTER STEEL DO .040 700 .348 1.7904 BOTTOM SEAL OPTIONS W'STRIPPING i {" R ANCHOR SPACING ANCHORS STRUCTURE EMBED I SPACING EDGE DIST. 3/8" HLC SLEEVE BY 'HILTI' CONC. 1-1/4" 8" 2" 3/8- CONFLEX BY 'ELCO' FILLED BLOCK 2" 8" 3-3/4" 3 8" DYNABOLT BY 'TTW' CONC. 1-1/2" 8" 3" 3/8" POWER -BOLT BY 'POWERS' CONC. 2" 8" 2" 3/8" SLEEVE -ALL BY 'SIMPSONS' CONC. 1-t 2" 1 8" 3" CONCRETE Vc = 3000 PSI MIN. C-90 GROUT FILLED BLOCK Vm = 2000 PSI MIN. 1-1/4" X 2-1/2" X 14 GA CONT. STEEL ANGLE 12 GA. GALV. STEEL FLAT BRACKETS t3" LONG AT 12" O.C. IN DOOR OPNG. AT 18" O.C. ABOVE DOOR OPNG. CONNECTED TO CONT. ANGLE W/ (3) SPOT WELDS AT EACH SIDE ALTERNATE TRACK INSTALLATION EDGE DIST. 1-1/2" 2-1/8" X 1" X 14 GA. GALV. STEEL TRACK FASTENED TO TRACK PLATES W/ (2) 1/4-20X5/8" TRUSS HD. SLOTTED M.S. & LOCK NUT CONTINUOUS ANGLE TRACK TO CONCRETE AND FILLED BLOCK F — 011 �9 io r • m .70592 a a= N o r W N co °' I � M J N z 0 o V 00 n w — 7 x N 17 LL N W 0 Q n a-, W 0 00 O o U 0) 0 N W L O N J p z N L 0 0 d DO 0) vs N < m m r� a o I ¢ v m a n O V y drawing no. 98-05 sheet 5 of DOOR PANEL 24 GA. (.024) STEEL MIN. 7/16" DIA. WASHER R PANEL GA. (.024) STEEL MIN. 21 3/4" MAX. �_#8 X 3/4" SMS I II I ® 3/8" FROM ENDS O 1 w I II AND 7" O.C. MAX. a I ILII ' o N Jo I. (4) #8 X 3/4" SMS 0 0 1-3/8" FROM ENDS IIII I AND 6-1/2" O.C. MAX. I: - IIII .175 X .062 DEEP I I Illj GROOVE IIII 1/4" POLYCARBONATE LEXAN BY 'SABIC INNOVATIVE PLASTICS' �I!I NOA #15-0915.08 � ILII � O a Ld o w � X jljl o w I.1 IIII III Ili! .175 X .062 DEEP GROOVE III II Ijl I i (4) #8 X 3/4" SMS ® 1-3/8" FROM ENDS I' j j j I AND 6-1/2" O.C. MAX. O 1 . C 1 I #8 X 3/4" SMS ® 3/8" FROM ENDS AND 7" O.C. MAX. 7/16" DIA. WASHER R PANEL GA. (.024) STEEL MIN. 21 3/4" * PLASTIC COMPLIES WITH CHAPTER 26 OF FBC SEE EVIDENCE PAGE Kim —.500 250 4. o I 0� ° c4i.� n w Q 2 ID K W N 1.765 1.725 Q S QW N 1,144 d > N 0CF o�Nn LLL M ,176 ,800 Q S 0 0 00 * EXTERIOR FRAME * INTERIOR FRAME C R O RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION Q w LL m LL Z N - o M J z M a w w 0) i i i #8 X 3/4" SMS ® 3/8" FROM ENDS AND 4-1/2' O.C. MAX. DOOR PANEL 24 GA. (.024) STEEL MIN. INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION .175 X .062 DEEP 15/16" MIN. WINDOW WIDTH EXTERIOR D.L. OPG. 6..t, 6y 2•064 �i �. • VlCER9y�"°•.° No 70592 YE OF ��° MAX. WDW. WIDI w 18 1/8" a x o MAX. o N Jo D.L.O. 3 0 A * PLASTIC COMPLIES WITH CHAPTER 26 OF FBC SEE EVIDENCE PAGE Kim —.500 250 4. o I 0� ° c4i.� n w Q 2 ID K W N 1.765 1.725 Q S QW N 1,144 d > N 0CF o�Nn LLL M ,176 ,800 Q S 0 0 00 * EXTERIOR FRAME * INTERIOR FRAME C R O RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION Q w LL m LL Z N - o M J z M a w w 0) i i i #8 X 3/4" SMS ® 3/8" FROM ENDS AND 4-1/2' O.C. MAX. DOOR PANEL 24 GA. (.024) STEEL MIN. INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS OWINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION .175 X .062 DEEP 15/16" MIN. WINDOW WIDTH EXTERIOR D.L. OPG. 6..t, 6y 2•064 �i �. • VlCER9y�"°•.° No 70592 YE OF ��°