Loading...
HomeMy WebLinkAboutProduct Approval - Steamer CONTRACTOR COPY FILE COPY _mr, steam.steam bathS Technical Specifications Model 4 E RECEIVED Serial Number 9000000 and higher MAR '2 1 7010 ®® Permitting Department St. Lucie Count o 0 Mr.Steam Standard Features � •Stainless steel resevoir' •Industrial,large diameter,serviceable heating element • Modular"snap-in"connections •Electronic water-level control system •Full-port drain valve. •Limited lifetime steam generator parts warranty Safety Features • UL recognized electronic controller system • Built-in,low-voltage 24-volt control •6o-minute electronic countdown with 75-minute limiting safety back-up •ASME safety valve Locating and installing Electrical the Steam Generator Unit •Select a location as near as practical to the steam room,within 50 feet. All electrical wiring to be installed by a qualified licensed electrician in Typical locations include:closet,vanity cabinet,heated attic or basement. accordance with National Electrical Code and local electrical code. • Do not install steambath generator inside the steam room. • Do not install steambath generator outdoors or wherever environmental Power Wiring conditions may affect the safety and/or performance of the generator. a.Check power voltage.Use 24oV rated unit when supply is greater than 208V.(Most homes have z4oV,iPH service).Use 208V rated •Do not install steambath generator or plumbing lines in unheated attic or any locations where water could freeze. unit for 208V power. 2.Use minimum 90•C/300V rated insulated copper conductors only, •Do not install steambath generator near flammable or corrosive materials type THHN or equal sized in accordance with National Electrical or chemicals or in areas having a high concentration of chlorine. Code and local electrical code for the Amps in Ampere Chart.If •Install steambath generator on a solid and level surface or securely allowed by code,NM cable may require a larger wire size than as mounted to a wall using the keyhole slots provided. listed on the chart. •Install steambath generator in an upright position only. 3.Connect suitably sized equipment grounding wire to ground terminal provided. •Provide minimum of(12) inches both ends and top of the steam 4.Install a separate circuit breaker between supply and.unit.Provide a generator r or as required for servicing. power supply disconnect within sight of the steam generator or one Refer to Mr.Steam Installation,Operation and Maintenance Manual Puri that is capable of being locked in the open position. 101289 REV 10.08 or later for complete instructions. 5,For single phase units,use two_wire supply source and equipment grounding wire.Neutral(white)wire is not required. Required Plumbing Water Supply(3/8"NPT) Steam outlet(1/2"NPT) AMPERE CHART Safety Valve(3/4" NPT) Drain(i/2"NPT) Model No. Max Room KW Volts Amps Wire Size Steam Head(2/2"NPT) Vol.Cu.Ft. i PH t (AWQft MS400E 360 9.0 208 44 8 •Locate steam head 6-12 inches above floor. 240 38 8 •For tub/shower enclosures,install 6 inches above tub top edge. •Consult with supplier of acrylic,fiberglass and other non-heat resist- t All specifications shown are for 208V and 24oV,single phase. ant enclosures for recommended steamhead location.An acrylic shield Consult factory for other voltage specifications. is available for these installations(part number 103938). tt See power wiring,note 2 above. {KFIVED p� FILE CS' Y MAR 2 � 1.018 mr.Stea�� e baths Technical SpecificaAAfliw ele��'t"„ent Generator Diagram Model MS400E 13/4" (45) ® U ® 14314" ® ® Water Inlet (375) Control& ® ® °O° Accessory ®®� 117/s" Connections (302) Steam Outlet Safety Value 8114" (210) Optional AutoFlush 1 51/s" Manual Drain Value (130) ---------- ' 13/4" o (45) 141/2" 631s„ 17 (368) (48) 21/2" (162) 51/8" (64) 5" (130) IMPORTANT NOTE: 6314 (127) Provide a minimum of twelve(12)inches (171) at both ends and top of the steam generator or as required for servicing.Alternately,provide unions as required to facilitate installation and disconnection of the steam generator. [7 U Side View Showing Element Access Panel IMPORTANT NOTE: The minimum clearance from combustible 0 surfaces is zero all around. ; IMPORTANT NOTE: ® .� Do not rough in plumbing and electrical services based in the dimensional information provided. Drawings are not to scale. ® NOTES: i.M=Optional AuwFlush 0 0 2.Al units in inches(MM) TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLYTO HEATING ELEMENTS III NOTE:FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT:See Mr.Steam®Installation, Operation and Maintenance Manual, PUR 101289,for details.Click here to download this manual: http://mrsteam.com/products/technical-downloads.htmi 2