Loading...
HomeMy WebLinkAboutProduct Approval - steamer A60NTRACTOR COPY FILE COPY mr, steanristeam baths Technical specifications Model MS400E RECEIVED, Serial Number 9000000 and higher MAR 11 7018 Permitting Departmem St.Lucie Counts, a 0 Mr.Steam Standard Features J ® •� •Stainless steel resevoir' •Industrial,large diameter,serviceable heating element oen •Modular"snap-in"connections •Electronic water-level control system •Full-port drain valve. •Limited lifetime steam generator parts warranty Safety Features -UL recognized electronic controller system -Built-in,low-voltage 24-volt control -6o-minute electronic countdown with 75-minute limiting safety back-up -ASME safety valve Locating and installingElectrical the Steam Generator Unit All electrical wiring to be I.nstalled by a qualified licensed electrician in •Select a location as near as practical to the steam room,within 50 feet. accordance with National Electrical Code and local electrical code. Typical locations include:closet,vanity cabinet,heated attic or basement. • Do not install steambath generator inside the steam room, power Wiring • Do not install steambath generator outdoors or wherever environmental :L.Check power voltage,Use 240V rated unit wl4en supply is greater conditions may affect the safety and/or performance of the generator. than 208V.(Most homes have 24oV,iPH service).Use 208V rated •Do not install steambath generator or plumbing lines in unheated attic unit for 208V power. or any locations where water could freeze. 2.Use minimum 90'C/300V rated insulated copper conductors only, •Do not install steambath generator near flammable or corrosive materials type THHN or equal sized in accordance with National Electrical or chemicals or in areas having a high concentration of chlorine. Code and local electrical code for the Amps in Ampere Chart.If •install steambath generator on a solid and level surface or securely allowed by code,NM cable may require a larger wire size than as mounted to a wall using the keyhole slots provided. listed on the chart. •Install steambath generator in an upright position only. 3-Connect suitably sized equipment grounding wire to ground terminal provided. •Provide a minimum of(12)inches at both ends and top of the steam 4.Install a separate circuit breaker between supply and unit.Provide a generator or as required for servicing. power supply disconnect within sight of the steam generator or one Refer to Mr.Steam Installation,Operation and Maintenance Manual PUR that is capable of being locked in the open position. 101289 REV 10.08 or later for complete instructions, 5,f6r.s-in&phase units,use two-wire-supply-source and equipment grounding wire.Neutral(white)wire is not required. Required Plumbing AMPERE CHART; — Water Supply(3/8'NPT) Steam Outlet(1/2"NPT) Model No. Max Room KW Volts Amps Wire Site SafetyValve(314" NPT) Drain(2/2"NPT) Vol.CuXt. I pHt (AWG)tt Steam Head(2/2"NPT) MS400E 360 9.0 208 44 8 •Locate steam head 6—12 inches above floor. 240 38 8 •For tub/shower enclosures,install 6 inches above tub top edge. •Consult with supplier of acrylic,fiberglass and other non-heat resist- t All specifications shown are for 208V and 24oV,single phase. ant enclosures for recommended steamhead location.An acrylic shield Consult factory for other voltage specifications. is available for these installations(part number 103938). tt See power wiring,note 2 above. RECENED HOLF COPY MAR 2 7.018 mr.steam® baths Technical Specifics"tame pePar'-Me" St—ucle Count%f Generator Diagram Model MS400E 13/4° z�'-7c( 143/4° ® ® (375) Water Inlet 00o Control& ®® ® ® Accessory 117le Connections %2j A Steam Outlet Safety Valve 81/4" (210) Optional AutoFlush 51/8" At"Manual Drain Value (130) ---------- ' (45) �- 141/2" 63/$n 17/s" (368) 21/2" (162) 51/8,(48j (64) 5" (130) IMPORTANT NOTE: 63/4„ (127) Provide a minimum of twelve(12)inches (171) at both ends and top of the steam'generator or as required for servicing.Alternately,provide unions as required to facilitate installation and disconnection of the steam generator. U Side View Showing Element Access Panel IMPORTANT NOTE: , The minimum clearance from combustible i surfaces is zero all around. IMPORTANT NOTE: Do not rough in plumbing and electrical services based in the dimensional information provided. Drawings are not to scale. ® NOTES: i.M=Optional AumFlush 0 0 2.All units in inches(MM) TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLYTO HEATING ELEMENTS III NOTE:FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT.See Mr.Steam®Installation,Operation and Maintenance Manual, PUR 101289,for details.Click here to download this manual: http://mrsteam.com/products/technical-downloads.htmi 2