mr, steanristeam baths Technical specifications
Model MS400E RECEIVED,
Serial Number 9000000 and higher MAR 11 7018
Permitting Departmem
St.Lucie Counts,
a 0
Mr.Steam Standard Features J ® •�
•Stainless steel resevoir'
•Industrial,large diameter,serviceable heating element oen
•Modular"snap-in"connections
•Electronic water-level control system
•Full-port drain valve.
•Limited lifetime steam generator parts warranty
Safety Features
-UL recognized electronic controller system
-Built-in,low-voltage 24-volt control
-6o-minute electronic countdown with 75-minute limiting
safety back-up
-ASME safety valve
Locating and installingElectrical
the Steam Generator Unit All electrical wiring to be I.nstalled by a qualified licensed electrician in
•Select a location as near as practical to the steam room,within 50 feet. accordance with National Electrical Code and local electrical code.
Typical locations include:closet,vanity cabinet,heated attic or basement.
• Do not install steambath generator inside the steam room, power Wiring
• Do not install steambath generator outdoors or wherever environmental :L.Check power voltage,Use 240V rated unit wl4en supply is greater
conditions may affect the safety and/or performance of the generator. than 208V.(Most homes have 24oV,iPH service).Use 208V rated
•Do not install steambath generator or plumbing lines in unheated attic unit for 208V power.
or any locations where water could freeze. 2.Use minimum 90'C/300V rated insulated copper conductors only,
•Do not install steambath generator near flammable or corrosive materials type THHN or equal sized in accordance with National Electrical
or chemicals or in areas having a high concentration of chlorine. Code and local electrical code for the Amps in Ampere Chart.If
•install steambath generator on a solid and level surface or securely allowed by code,NM cable may require a larger wire size than as
mounted to a wall using the keyhole slots provided. listed on the chart.
•Install steambath generator in an upright position only. 3-Connect suitably sized equipment grounding wire to ground terminal
provided.
•Provide a minimum of(12)inches at both ends and top of the steam
4.Install a separate circuit breaker between supply and unit.Provide a
generator or as required for servicing. power supply disconnect within sight of the steam generator or one
Refer to Mr.Steam Installation,Operation and Maintenance Manual PUR that is capable of being locked in the open position.
101289 REV 10.08 or later for complete instructions, 5,f6r.s-in&phase units,use two-wire-supply-source and equipment
grounding wire.Neutral(white)wire is not required.
Required Plumbing AMPERE CHART; —
Water Supply(3/8'NPT) Steam Outlet(1/2"NPT) Model No. Max Room KW Volts Amps Wire Site
SafetyValve(314" NPT) Drain(2/2"NPT) Vol.CuXt. I pHt (AWG)tt
Steam Head(2/2"NPT) MS400E 360 9.0 208 44 8
•Locate steam head 6—12 inches above floor. 240 38 8
•For tub/shower enclosures,install 6 inches above tub top edge.
•Consult with supplier of acrylic,fiberglass and other non-heat resist- t All specifications shown are for 208V and 24oV,single phase.
ant enclosures for recommended steamhead location.An acrylic shield Consult factory for other voltage specifications.
is available for these installations(part number 103938). tt See power wiring,note 2 above.
RECENED
HOLF COPY MAR 2 7.018
mr.steam® baths Technical Specifics"tame pePar'-Me"
St—ucle Count%f
Generator Diagram Model
MS400E
13/4°
z�'-7c(
143/4°
® ® (375)
Water Inlet
00o Control& ®®
® ® Accessory 117le
Connections %2j
A Steam Outlet
Safety Valve 81/4"
(210)
Optional AutoFlush 51/8"
At"Manual Drain Value (130)
---------- '
(45)
�- 141/2" 63/$n 17/s"
(368)
21/2" (162) 51/8,(48j
(64) 5" (130)
IMPORTANT NOTE: 63/4„ (127)
Provide a minimum of twelve(12)inches (171)
at both ends and top of the steam'generator or as
required for servicing.Alternately,provide unions as
required to facilitate installation and disconnection
of the steam generator. U Side View Showing
Element Access Panel
IMPORTANT NOTE: ,
The minimum clearance from combustible i
surfaces is zero all around.
IMPORTANT NOTE:
Do not rough in plumbing and electrical services
based in the dimensional information provided.
Drawings are not to scale.
® NOTES:
i.M=Optional AumFlush
0 0 2.All units in inches(MM)
TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER
SUPPLY DIRECTLYTO HEATING ELEMENTS III
NOTE:FOR ILLUSTRATIVE PURPOSES ONLY.
IMPORTANT.See Mr.Steam®Installation,Operation and
Maintenance Manual, PUR 101289,for details.Click here
to download this manual:
http://mrsteam.com/products/technical-downloads.htmi
2