HomeMy WebLinkAboutProduct Approval Architectonic Inc RECEIVED
MAR 14 1016
Permitting Department
St. Lucie Count
March 7, 2018
RLE COPY
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
23QO Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure
located at 2 Tikal Lane., Saint Lucie County, Florida
Manufacturer: Polyglass USA
Profiles: Modified Bitumen Roof System, FL#1654-R22
Code: FBC 2017;Section 1507
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: C
Mean Roof Height: 30' Maximum
Pitch: 1/12 Minimum
Required Design Pressure: Zone1:-31.46 Zone 2:-49.61 Zone3:-68.97
Maximum Uplift Pressure: -90 psf
Base: SBS-SA(self-adhering)
Ply Sheet: (Optional)One or more Elastoflex SA V Base (self-adhering)
Cap: SBS-SA,SBS-TA,APP-SA,APP-TA(self-adhering)
Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1,4" O.C. perimeter,and 6" O.C.field zone 2,
and 4" O.C.thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
.fie OF F`
,`1,, ........ .. O
es�ectfully submitfi��
NNIGHAEC
s
ARAR
+ ra I Seal V
I tonic.l
�D ARG
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1
,�..
Professional Regulation
r�a�r
SCIS Home I Log In I User Itegtstration Hot Topic f Submit Surcharge i Stats&Facts Publlcatlons FBC Staff
805 Site Map Llaks ( Search
Florida
l: Product Approval
�. R USr:N:public User
Product Approval Menu>product or Application Search>Appijrattm L!st>Application Detail
FL# FL1654-R22
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived L7
Product Manufacturer POLYGLASS USA
Address/Phone/Emall 150 Lyon Drive
Fernley,NV 89408
(570)384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(912)429-8610
MAlpertOpolyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1230
ALender@polyg lass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
II Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W.Knezevlch,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence PLIfi54 R22 COI 2017 01 GOI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM-D6162 2008
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4470 2012
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/14/2017
Date Validated 09/15/2017
Date Pending FBC Approval 09/22/2017
Date Approved 12/12/2017
Summary of Products
FL.# Model,Number or Name Description
1654.1 Polygiass SBS and APP SBS and APP modified bitumen roof systems
Modified Bitumen Roof
Systems
Limits of Use Installation Instructions
Approved for use in HVHZ:No Flt 654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
Approved for use outside HVHZ:Yes R22.Ddf
Impact Resistant:N/A Verified By:Robert Nleminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other:1.)The design pressure in this Evaluation Reports
application relates to one particular assembly FI 1654 g22--AEE 2017 09 FINAL ER POLYGLASS MODBIT FL1654-
over concrete deck.Refer to the ER Appendix for R22.Ddf
other systems and deck types.2.)Refer to ER, Created by Independent Third Party:Yes
Section 5 for other Umits of Use.
Back Next
Contact Us;;2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of lorlda Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement r:Refund Statement
Under Floridn law,email addresses are public records.It you do not want your a-mall address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.•Pursuant to Section 455.275
(1),Flodda Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address Ifthey have one.The
emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click re .
Product Approval Accepts: .
®®®M
Credit Card
Safe
EXTERIOR RESEARCH&DESIGN,U.C.
1 Certificate of Authorization#9503
353 Christian Street
TRINITY I ERD Oxford,CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P9290.02.08-R20
150 Lyon Drive F1.1654.1122
Fernley,NV 89408 Date of Issuance:02/11/2008
(570)384-1230 Revision 20:00/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6ei Edition(2017)Florida Building Code sections noted herein.
DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6,plus a 58-page Appendix.
Prepared by: »�="t�t'�,►•.
Robert J.M.Nieminen,P.E. {.`�lj�'Zio ta
ThealmilesealappearingwasauthorizedbyRobertNleminen,
'Jlu.arar
Florida Registration No.59166,Florida DCA ANE1983 -� P.E.on 09/12/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1, Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD Is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
`"'J TRINITY ER®
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA,
Inc., have demonstrated compliance with.the following sections of the 6th Edition (2017) Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind FM 4474 2011
1504.3.1 Wind UL 1897 2012
1504.7 Impact FM 4470 2012
1507.11.2 Physical Properties ASTM D6162 2008
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011
1507.11.2 Physical Properties ASTM D6509 2009
3. REFERENCES:
99ity Examination Reference Date
ERD(TST6049) Physical Properties P10490.10.08-2 10/30/2008
ERD(TST6049) FM 4470/4474 P13760.09.09 09/10/2009
ERD(TST6049) FM 4470/4474 P13770.09.09 09/10/2009
ERD(TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009.
ERD(TST6049) FM 4470/4474 P30550.12.09 12/02/2009
ERD(TST6049) Physical Properties P33960.12.10 12/30/2010
ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011
ERD(TST6049) Physical Properties P37590.03.13-3A 03/06/2013
ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013
ERD(TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013
ERD(TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013
ERD(TST6049) Physical Properties P37590.07.13-2 07/01/2013
ERD(TST6049) Physical Properties P37590.03.13-5-Ri 07/01/2013
ERD(TST6049) Physical Properties P37590.07.13-1 07/02/2013
ERD(TST6049) FM 4470/4474 P41630.08.13 08/06/2013
ERD(TST6049) Physical Properties P45940.09.13 09/04/2013
ERD(TST6049) Physical Properties P44370.10.13 10/04/2013
ERD(TST6049) Physical Properties P39520.09.14-2 09/11/2014
ERD(TST6049) FM 4470/4474 SC6160.11.14 11/10/2014
ERD(TST6049) Physical Properties PLYG-P45440SC.03.15-1 03/31/2015
ERD(TST6049) Physical Properties SC5170.05.15 05/08/2015
ERD(TST6049) FM 4474 SC8085.05.15 05/19/2015
ERD(TST6049) Physical Properties SC5170.12.15 12/29/2015
ERD(TST6049) FM 4470/4474 SC9455.15 04/01/2016
ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016
ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016
ERD(TST6049) FM 4470/4474 PLYG-SC10815.07.16-R1 09/23/2016
ERD(TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016
ERD(TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016
ERD(TST6049) FM 4470/4474/UL1897 PLYG-SC13235.01.17 01/17/2017
ERD(TST6049) FM 4474/UL1897/TAS 114 PLYG-SC13920.05.17 05/30/2017
ERD(TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-1 05/30/2017
Exterior Research and Design,U.C. Evaluation Report 139290.02.08-1120
Certificate of Authorization 119503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL3654-RZ2
Polyglass Modified Bitumen Roof Systems;(570)384-1230 Revision 20:09/12/2017
Page 2 of 6
�. TRINITY i ERD
i
Enti Examination Reference Date
ERD(TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-3 05/30/2017
ERD(TST6049) FM 4474/UL1897 PLYG-SC13945.05.17 05/30/2017
ERD(TST6049) FM 4474/TAS 114 PLYG-SC15760.09.17 09/11/2017
FM Approvals(TST1867) FM 4470 2W7A7.AM 08/04/1994
FM Approvals(TST1867) FM 4470 OD3A3.AM 04/04/1997
FM Approvals(TST1867) FM 4470 2DOAO.AM 12/23/1998
FM Approvals(TST1867) FM 4470 2D5A9.AM 06/22/1999
FM Approvals(TST1867) FM 4470 3006646 01/04/2000
FM Approvals(TST1867) FM 4470 3001334 01/25/2000
FM Approvals(TST1867) FM 4470 3001334 02/15/2000
FM Approvals(TST1867) FM 4470 3000857 01/12/2000
FM Approvals(TST1867) FM 4470 3004091 01/12/2000
FM Approvals(TST1867) FM 4470 3006115 05/02/2001
FM Approvals(TST1867) FM 4470 3012321 07/29/2002
FM Approvals(TST1867) FM 4470 3014692 08/05/2003
FM Approvals(TST1867) FM 4470 3014751 08/27/2003
FM Approvals(TST1867) FM 4470 3007170 01/13/2004
FM Approvals(TST1867) FM 4470 3019317 06/30/2004
FM Approvals(TST1867) FM 4470 3020703 07/30/2004
FM Approvals(TST1867) FM 4470/4474 3018332 01/31/2006
FM Approvals(TST1867) FM 4470/4474 3023368 03/20/2006
FM Approvals(TST1867) FM 4470/4474 3024594 05/23/2006
FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006
FM Approvals(TST1867) FM 4470/4474 3030668 09/12/2007
FM Approvals(TST1867) FM 4470/4474 3032172 06/12/2009
FM Approvals(TST1867) FM 4470/4474 3049631 04/21/2014
FM Approvals(TST1867) FM 4470/4474 3057029 02/02/2017
PRI(TST5878) Physical Properties PUSA-062-02-01 12/04/2007
PRI(TST5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST5878) Physical Properties PUSA-064-02-02 02/27/2008
PRI(TSTS878) Physical Properties PUSA-062-02-02 12/04/2008
PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017
PRI(TST5878) TAS 114 PUSA-188-02-02 02/08/2017
PRI(TST5878) TAS 114 PUSA-188-02-03 02/08/2017
PRI(TST5878) TAS 114 PUSA-202-02-01 05/17/2017
PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017
Miami-Dade(CER1592) HVHZ Compliance Various NOAs Various
Miami-Dade(CER1592) Proposal for Review 10-0823 10/12/2010
UL LLC (QUA9625) Quality Control Service Confirmation,R14571 Exp.10/06/2018
4. PRODUCT DESCRIPTION:
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA,
Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass
membranes make up the subject systems.
TABLE 1{:ROLL-GOODS'FOR PULYGLASS MODIFIED BITUMEN ROOF SYSTEMS
Type Product Specification
Reference Grade Type
Polyglass G2 Base ASTM D4601 N/A 11
Base Sheets Polyflex SA Base ASTM D4601 N/A II
Polyglass APP Base ASTM D6509 N/A N/A
Exterior Research and Design,U.C. Evaluation Report P9290.02.08-1120
Certificate of Authorization 49503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems,(570)384-1230 Revision 20:09/12/2017
Page 3 of 6
ti ��• f
TRINITY I ERD
TABLE 1(CONTINUED�.ROLL GaADS FOR POLYGLASS(MODIFIED BITUMEN ROOBSYSTEMS'
Type Product Specification
Reference Grade Type
Polyglass HT Base 650 ASTM D6162 S III
Elastobase ASTM D6163 S I
Elastoflex V ASTM D6163 S I
Elastoflex SA V Base ASTM D6163,Table 2 S I
Elastoflex SA V FR Base ASTM D6163,Table 2 S I
SBS Membranes Elastoflex SA V Plus ASTM D6163 S I
Elastoflex SA V Plus FR ASTM D6163 S I
Elastobase Poly ASTM D6164 S I
Elastoflex S6 ASTM D6164 5 I
Elastoflex S6 Type II ASTM D6164 S 11
Elastoflex VG ASTM D6163 G I
Elastoflex VG FR ASTM D6163 G I
Elastoflex S6 G ASTM D6164 G I
Elastoflex S6 G FR ASTM D6164 G I
Polyfresko G SB5(sand or poly-film backed) ASTM D6164 G 1
Polyfresko G SBS FR(sand or poly-film backed) ASTM D6164 G I
SBS Membranes Elastoshield TS G ASTM D6164 G I
Elastashield TS G FR ASTM D6164 G I
Elastoflex SA P ASTM D6164 G I
Elastoflex SA P FR ASTM D6164 G 1
Polyreflect ASTM D6164 S I
Polyflex ASTM D6222 S I
Polyflex G ASTM D6222 G I
Polyflex G FR ASTM D6222 G I
Polyfresko G ASTM D6222 G I
Polyfresko G FR ASTM D6222 G I
APP Membranes Polybond ASTM D6222 S I
Polybond G ASTM D6222 G I
Polyflex SA P ASTM D6222 G I
Polyflex SA P FR ASTM D6222 G I
Polyfresko G SA ASTM D6222 G I
Polykool ASTM D6222 S I
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design.guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and.structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction. Load resistance of the roof deck shall be documented throu& proper codified and/or FBC
Approval documentation.
5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511.
Exterior Research and Design,I.I.C. Evaluation Report P9290.02.08-1120
Certificate ofAutharhotion#9503 6T"EDITION(2017)FBC NON-IiVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems;(570)384-1230 Revision 20:09/12/2017
Page 4 of 6
TPJNI-ff'ERD
5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with
FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss
Prevention Data Sheet 1-29,Roofing Application.Standard RAS 117 and Roofing Application Standard RAS
237. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks,fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI
FX-1 or Testing Application Standard TAS 105.
5-10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ANSI/SPRI[A-1,ASTM E907,FIVI Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS
124 shall be conducted on mock-ups of the proposed new roof assembly,
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof
system shall be capable of resisting project design pressures on its own merit to the satisfaction of the
Authority Having Jurisdiction,as documented through field uplift testing in accordance with ASTM E907,FM
Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment(except gutters), shall be designed and installed for wind loads in accordance with
FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard
RAS 211, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or
1609.3(3).
5.23 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61620-3.
6. INSTALLATION;
6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA,Inc.published
installation instructions,subject to the Limitations/Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable Wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied).Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC. Evaluation Report P9290.02.08-R20
Certificate of A uthorhadion#9503 EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R2Z
Polyglass Modified Bitumen Roof Systems,(570)384-1230 Revision 20:09/12/2017
Page 5 of 6
'-J TRINITY i ERD
6.3 Any of the fallowing FBC Approved coatings may be applied to the top roof membrane without adverse effect
on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated
with coating usage.
➢ PG200 Non-Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
➢ PG700QS(Quick-Set)High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule-surfaced
APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
➢ Polybrite 70QS(Quick-Set)Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS(aver granule-
surfaced APP or SBS only);
➢ Polybrite 90 High Solids Silicone Roof Coating;
Polybrite 95 Silicone Roof Coating.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61620-3 QA
requirements
9: QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(314)578-3406,k.chancelior@us.ul.com
-THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report P9290.02.08-R20
Certificate of Authorization 49503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems;(570)384-1230 Revision 20:09/12/2017
Page 6 of 6
�.f TRINITY i ERD
TABLE IF-2:.WOODDECK4:�NEWCONSfROCiION REROOF.(TPnri-OFP)ce'RecoVER'
1, --��SYSTEMTYBEE NON4NSULA7ED;MECHANICALLXATTkHEDBASESHEET(sciEWsS.6i*ia);BONDEDROOECO%iER
System Duck(Note 1) Base Sheet Roof-Cover(Note 15) MDP
No. Type Fasten Attach Base Ply Cap (PA
5DF-ADHvjwBAse PLy. - -W-136 Min.29/32- Elastobase,Elastobase P Dekfast Hex(aka,Oekfast PLT-H-2-7/8)with Dekfast#14 12-Inch c.c.in 4-inch lap and 12-inch a.c.in two SBS-SA SBS-SA,APP-SA,SBS -52.5*
Inch plywood (poly-flimtop) or Tmfast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows TA,APP-TA
W-137
Min.29/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-Inch o.c.in 4-inch lap and 12-Inch o.c.in two polyftez SA Base APP TA J5251Inch plywood (poly-fllmtop) orTrufast 3"Metal insulation Plate with Trufast HD (2),equally spaced,staggered center rowsW-138 Min.19/32- Elastobase,Elastabase P OMG Flat Bottom Plates(square)with Roofgrip 812 12-Inch o.c.In 4-Inch lap and 12-Inch o.c.In two SBSSA SBS-SA,APP-SA,SBS-inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APPTA
W-139 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Raofgrlp#12 12-Inch o.c_in"ch lap and 12-inch o.c.In two Polyflex SA Base APPTA
Inch plywood (poly-film top) (2),equally spaced,staggered center rows
_.TABLE 1Gt:WOOD.DECK$—NEWCONSiRULT(ONaRREROOF.(TEAd-OFF)
. SYSfEMTYPEFCNON-INSULATED BONDEDIROOFCOVER -
.. ... .. _
System Deck(Note 1) Primer
covermer (Note]5) MDP(psi)
No. -,joint.Treatment =r:;,^;.rJ"; -- ,,,Base Ply._ - Ply Cap Ply
t On,15/32 r - (Optional)s ly 59S-SA APP 5A,SBS,
Nane• None •..'
-SBS
-90.0
TA;APP TA
W-141 Min.15/32-
Inch plywood (Optional)PG100 None •- _ - Polyllex SA Base~ (Optional)APP-TA APP TA •90.0
W-142 Min.15/32- PG'- None SBS-SA (Optional)SBS-SA,SBS SBS-SA,APP-SA,SBS- 975
Inch plywood TA,APP-TA TA,APP TA
Min.25/32- Plywood joints are covered with 4-Inch wide strips ofElastoftex SA V Plus,rolled into Elastoflex SAV Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-143 Inch plywood (Optional)PG300 place to create continuous bond. Elastollex SA V FR Base TA,APP-TA TA,APP-TA -97'5
W-1" Min.15/32- V113-3000 None SBS-SA (Optional) SBS-SA,APP-SA,SBS- _105.0
Inch plywood TA,APP-TA
W-145 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastaflex SA V Plus,rolled Into Elastoflex SA V Plus or (Optional)SBS-SA,SBS SBS-SA,APP-SA,SBS- -135.0
Inch plywood place to create continuous bond. Elastoflex SAY Plus FR TA,APP-TA TA,APP TA
W-146
Min.15/32- (Optional)PG300 Plywood joints are covered with 4-Inch wide strips of Elastoilex SA V Plus,rolled into Polyflex SA Base (Optian.Q APP-TA APP-TA -135.0
Inch plywood place to create continuous bond.
Exterior Research and Design,LLC d/b/a Trinity(ERD Evaluation Report P9290.02.08-1120 for FL3654-R22
Certificate of Authorcation#9503 6D'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared by.Robert Nleminen,PE-59166 Polygiass Modified Bitumen Roof Systems;(570)384-MO Appendix 1,Page 21 of5S