Loading...
HomeMy WebLinkAboutBaker Permit Packet ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: Building Permit Application Planning and Devebprrnnt Services Building and Code Regulation Division 2300 Viril Avenue,Fort Pierce Ft 34992 Phone:(772)462-1553 Fax: (772)462-1578 Commercial Residential PERMIT APPLICATION FOR: F- �l h>k s w M Address: 7402 OCALA AVE FT.PIERCE.FL 34951 Legal Description:LAKEWOOD PARK ADDITION NO 1 BLK B LOT 13 Property Tax ID#:1302-810-0040-000-9 Lot No.13 Site Plan Name: Block No.B Project Name:CYNTHIA&JEFF BAKER Setbacks Front Back:_Right Side: Left Side: Replacement Windows(11) Additional work o or un er s perm — e a apply, ❑HVAC Gas Tank as Piping Shutters �windows/Doors ❑Electric 0 Plumbing [:]SprinklersGenerator Roof Total Sq.Ft of Construction: S .Ft.of First Floor: Cost of Construction:$ 12,800.00 Udlities:tSewer E]Septic Building Height: Name CYNTHIA&JEFF BAKER Name:Sam Ochstein Address. 7402 OCALA AVE Company:Newsouth Window Solutions City: FT.PIERCE State: FL Address:2526 Okeechobee Blvd. Zip Code: 34951 Fax: City:West Palm Beach State:FL Phone No. Zip Code: 33409 Fax:5614784100 E-Mail: Phone No. 561-712-9000 Fill In fee simple Title Holder on next page(ff different E-Mail:westpalmbeacbgnewsouthwindow.com from the Owner listed above) State or County License:CRC1330822 If value of construction Is$Z900 or more,a RECORDED Notice of commencement Is required. DESIGNE ENGINEER: Not Applicable MORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name. Address: Address: City: city: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the Issuance of a permit. 5t.Lucke County malt no repre5e%fion that is granting a permit will authorize the permit holder to bulkd the ubject str7��ture whIc is in conflict wltt an, appluable Home Owners Association rules,bylaws or and covenants that may restri5et or prohl6R such structure.Please consult with your Nome Owners Association and review your deed for any restrictions which may apply. In consideratkm of the granting of this requested permit,I do hereby agree that I will, in all respects,perform the work In accordance with the approved plans,the Florlda Building Codes and St.Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residentlal use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording your Notice of Commencement. e g Signature of chlmerlAgent/Lessee Signature o ntr s o der STATE OF FLORID' STATE OF FL A COUNTY OF • I V C2� COUNTY OF I GUth�o G C The rgoing instrument w s acknowledged before me The forgoing instrument was acknowledged before me th N day of iN2ar 20 It by thI5V_&dayoFM4'�c- .7A,A by G>- n (Name of person acknowledging) (Name of person acknowledging) (Signature of Notary Public-State of Florida) ��� f5lgnature of Notary Public-State of Florida) Personally Known OUrroduced Identificatb6— Personally Known OR Produced Identification Type of Identification Produced sIIC s LXC_ Type of Identingti n Produced Commission No. Commission No. al) KIM A.STONE F"°` KIM A.STONE MY COM Revised07/15/20 EXPIRES.00oba 15,2019 �ahej erfkesaronau,zol9 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS _,TOSEPH E. SMITH, CLERIC OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 4400399 OR BOOK 4096 PAGE 1414, Recorded 02/12/2018 03:15 :06 PM NOTICE OF COMMENCEMENT Penult No. Property Tax ID No,1302-910-004"W.9 j State of Florida,County of St.Lade The Undersigned hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,the following bAbrmadon is provided In this Notice of Commencement. Legal Description of property and address if available __— .— ^_ I LAKEWOOD PARK ADDMON NO I BLK B LOT 13 General description of Improvements Replacement Windows, ` — a F OwneeleweeCYNCHIA&JEFFBAKERcc Address 7442 OCALA AVE,FT.PIERCE,FL 34951 Interest In property: I— Fee Simple Title holder(it other than owner)_ —_—__ <Y „"'.. Ui Address W Contractor Newsouth Window Solution pbone#561-712-9000 J < Address 2526 Okeechobee Blvd,WEST PALM BEACH,FL 33409 Fax#561478�1100 < ---------- --- - Phone# 2S Address —_ Fax a Amount of Bond Lender-- _ Phone#_ Address —,--_-- _--- —i-- Fax# Persons within(tie State offlorlds designated byOwner upon whomnoticesor other documenumaybeserved asprovided {( by Section 713.13(a)7.,Florida Statues: v—V---- —'�— Name Address Fax#--- -- In addition to himself,owner designates i Fax# — — to receive a copy of the Llenor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Expiration date of notice of � commencement is one year from the date of recording unless a different dale is specified. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER TH6 EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CH.713.13,F.S.,AND CAN RFSULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMBNTMUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE F7Rsr1NSPECT70N.IF YOU INTENDTOOBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMFNCMEW, Owner/l,ta.ee, apr L .W.AWAwooy��OMM/DtrtretldYP9 w^te sw slpmY s+eamo,r•.no m.���'1 `! SIs�J� State of Florida,County of Acknowledged before me this _—ada—yoflGJ,jr=EW 2D At,by t S14V —�A wh Is personalty(mown to me or who has produced V1.. %�.I— _ as identification. Signature of Notary Type or Print Name of Notary (Seal) Tide:Notary Public Comnlssion Number RoM A.STONE MY CDMMA.S pFF92B006 Tjy1RPa:OaQbc If,2019 NewSouth WINDOW SOLUTIONS 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC 1330822 Property Information Building Information Owner: CYNTHIA&JEFF BAKER Wind Zone: 170 MPH. Address: 7402 OCALA AVE Exposure Category: C FT.PIERCE,FL 34951 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Des' n Pressure Calculations Opening Location Device Device Device Max Positive LMax Negative Number Zone Width(in) L.Height(in) Elevation(ft) Pressure(psf) Pressure(pst) 1 Int 35.5 49.5 7 37.3 -40.5 2 Int 72 49.5 7 35.6 -38.8 3 Int 35.5 49.5 7 37.3 -40.5 4 Int 18 25 7 37.8 41.0 5 Int 73 24.75 7 37.2 40.4 6 Int 36 36.25 7 37.8 -41.0 7 Int 18 24.75 7 37.8 -41.0 8 Int 36 49.5 7 37.3 -40.5 9 Int 73 24.75 7 37.2 -40.4 to Int 52 9.5 7 37.8 -41.0 11 Int 51.5 36.75 7 37.1 -40.3 Prepared in accordance with:ASCE 7-10,Chapter 30, Wind Loads-Componena and Cladding.6th Edition(1017)Florida Building Code. Page 1 of 1 J J O ^�V A V mS 12 �y2 ME tS -� �2 C �T Z �. m r3 N W x W x W Qp rT� N r X , x x x x �f x x x x J co � O V J N W W A N CYNTHIA & JEFF BAKER ---MNew out h N 7402 OCALA AVE WINDOW soLunoNs FT. PIERCE, FL 34951 /' 398 East Dania Beach Blvd, BUILDING DROPS Suite338 k Perfect Every 954.399.8478 PH Certificate1( of Authorizaza tion:29578 Dania Beach,FL 33004 578 954.744.4738 FX contact@buildingdrops.com January 30,2018 Eastern Architectural Systems 10030 Bavaria Road Ft Myers,FL 33913 Attn:Derek DeLuca RE: FL17472 61 Edition Florida Product Approval Submittal Process To whom it may concern: The purpose of this letter is to confirm that Building Drops,Inc.is in the process of updating Eastern Architectural System's product approval FL17472 to the 6v' Edition Florida Building Code (FBC), and to affirm that the product specifications, drawings and testing as previously listed under the S"' Edition FBC are compliant with 6th Edition FBC requirements, therefore in my professional opinion the products are acceptable for installations permitted under the 61' Edition FBC. Building Drops, Inc. is In the process of updating Eastern Architectural System's approvals through the Florida State Product Approval Program.A summary of the submittals in process is below,with corresponding approval numbers. Florida State FL# I Product FL17472.1 HVHZ Clipped Aluminum Bay/Bow Mullion FL17472.2 HVHZ Clipped Aluminum Tube Mullion I trust that this will satisfy your needs, however feel free to call if you have any questions. Respectfuliy`,tttt t II I IIIII,, 7 _ '9 T T . T '. by F.Norera, ,� 4SS%NA .Eli 3:I am app'Hermes n9 t�hi-0d cument P.E. Hermes F.Noreft,Vv II Florida Registered Professional Engineer#73778 Certification of Independence: Please note that I do not have nor will I acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also, I do not have nor will I acquire a financial interest in any other entity involved in the approval process of the listed product(s). Hermes F.Norero,PE FL PE 73778 Page 1 of 1 7/31/2017 Floride Ou1i g Coda Online Professional Regulation Bee Mane tog In I um aeol.bMbn ! Mot Taub I %Wit Surd vas I Snrs a r.Ln n44eatbn. I FDC SMr I acts Sea MOP I Unb I sarrh 1pr ®� '' >hdWcl er♦eegutien Surtn>/iaW Wn List,atVaraaaa sated Fly FL17472-R1 APpgCytian Tyce Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratHled by the POC and/or the Commission If necessary. Comments ArcMved Product Manufacturer Eastern Architectural Systems Addness/Phone/Emall 16341 Domestic Ave, Ft.Myers,FL 33912 (800)432.2204 Fitt 4305 )BesherOeastarnmetal.com Authorized Signature lames Flasher Jf asharilileathemmetal.com Technical Representative Timothy 3. Hoard Address/Phone/Emali 10030 Bavaria Road Fort Myers,FL 33913 (800)432.2204 Est 4314 dwardieastemmetal.com Quality Assurance Representative Address/Phone/Emali Category windows Subcategory Mullions Compliance Method Certification Mark or Usting Certillcatlon Agency Keystone Certifications,Inc. Validated By Keystone Certifications,Inc. Referenced Standard and year(of Standard) mid Y7� AAMA 450 2010 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A hto:/Avww.BotidebuAdlogat%W* app dd.eapd7paramavGEV%QwIDgICUG9 vC%2bOtoUJS%20WIPJShx%2"hV7eCf "%3d%3d 1/2 7/31/2017 Florida Building Code Online Date Submitted 03/24/2015 Date Validated 04/02/2015 Date Fending FBC Approval Date Approved 05/08/2015 Summam of Products FL i Model,Number or Name Description 17472.1 HVHZ Clipped Aluminum Bay/Bow HVHZ Clipped Aluminum Bay/Bow Mullion Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17472 RS C CAC 622-104CAR odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/22/2018 Design Pressure:N/A Installation Instructions Other:See drawing set for mullion size,angle and design FL17472 RS 11 PA-OD04 HVHZ SS 2015-02.28.0df pressure rating Verified By: Hermes F. Norero,P.E.73778 Created by Independent Third Party: Yes Evaluation Reports FL17472 RS AE PER3286 HVHZ SS 2015-02-28 odf Created by Independent Third Party:Yes j 17472.2 HVHZ Clipped Aluminum Tube HVHZ Clipped Aluminum Tube Mullion Vertical Horizontal T Mullion and X Configurations Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL17472 RI C CAC 622-301CAR.Ddf Approved for use outside HVHZ:Yes FL17472 R3 C CAC 622-102CAR.0df Impact Resistant:Yes FL17472 RI C CAC 622-103CAR.Ddf Design Pressure:N/A FL17472 R1 C CAC 622-105CAR.Ddf Other:See drawing set for mullion size,configuration and FL17472 RI C CAC 622-106CAR.0df design pressure rating Quality Assurance Contract Expiration Date 07/18/2018 Installation Instructions FL17472 R1 II PA-0003 HVHZ SS 2015-02-28.Ddf Verified By: Hermes F. Norero,P.E.73778 Created by Independent Third Party:Yes Evaluation Reports FL17472 RI AE PER3285 HVHZ SS 2015-02-28.ndf Created by Independent Third Party:Yes Contact us::2601 Blair Stone Road,Tallahassee fL 32394 Eheya,850-487-1824 The State of Ronda is an AOVEEO employee faoynoht 2007-2013 State of Ronda.::Privan Statement::Accessibility Satement::Refund Statement under Fonda law,email addresses are public records.If you do trot want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please waned 350.487.1395.`Pursuant to Sectbn 455.275(1),Fonda Statutes,effective October 1,201Z acemees licensed under Chapter 455,F.S.must provide Me Department with an email address it they have one.The email,proOded may as used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,pease pravide the Department with an email address which on be made&"liable ro the public.To determine If you are a licensee under Chapter 45s,F.S., please click tali. product Approval Accepts: ®El ®F__�M Credit Card Safe http://www.VoridabLilding.org/pr/pr_app_d0.aspx9param=wGEVXQwtDgtCUGgvjQiz6AvC%2bOtoUJ6%2fiWIPJ6hz%2fBgBhlf7cCfmsA%3d%3d 2/2 oxunat 7ltlr. Dw No: FRMa142 .._r---�_. _� Structural Performance ""No: ' "°' , a , t.YNF Certification .j�__i Authorization Report Required BY: PRO B1-03 CAR& Product ID Number: 622 - 104.0 Issue Date: 1N612015 Revision Date: 4I1/2015 Expiration Date: 9/22/2018 Company Code: 622 This Certification Authorization Report(CAR)Is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the spedfled referenced standard. Aclual fenestration product performance may vary based on many factors, including installation, condition of the walyroof substrate and the age of fife product and installation components. This report lWicales the product Is eligible for 1he application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products,that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in finis report can be verified at www.keyabnecorts.com. Licensee Information: Product information: Eastern Architectural Systems Model:Bay/Bow Aluminum Mullion 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Config: No Reinforcement Max Width: See Table Max Height: See Table Referenced Standard: Product Rating: AAMA 450-10&PAITAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-301 OW-10A Test Report Expiration: 9/22/2018 Authorized Signature: Digitally signed by Steven M.thkh Keystone Certifications, Inc. DN;cr-StevenM.Urich, 564 Old York Road, Suite 5 p o� �•/ o=tceystone Certifications,Inc,a,, Etters, Pennsylvania 17319 ema0=wndolceystonecertscom r-US Phone: 717-932-8500 Date:2015A4.01 11x1:23�44'e0' Fax: 717-932-8501 W W WA4YSrONECERTS.COM E, Appendix 1 CARNa622-Mo Expiration Date:9/22/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Wad Tablas for the: 22.5 Degree Bay/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:22.5 Deg. -ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 175.3 159.1 149.0 244.1 143.5 141.6 72 179.3 137.2 112.6 96.9 86.2 78.9 74.6 74.0 70.8 84 122.1 85.4 69.6 59.4 52.3 47.2 "A 43.6 40.9 96 74.8 56.7 46.1 39.1 34.2 30.7 28.4 28.0 26.0 108 52.3 39.6 32.1 1 27.1 23.6 21.1 19.4 19.1 17.7 DESIGN PRESSURE LIMITS FOR MULLION:22.5 Deg, -TWO-WAY MULUONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) IN.) 18 24 30 36 42 48 53,125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 187.5 184.5 166.0 48 200.0 200.0 200.0 200.0 177.9 155.7 140.6 138A 124.5 60 200.0 200.0 181.3 151.1 129.5 113.3 102.4 100.7 90.6 72 1 274.8 131.1 104.9 87.4 74.9 65.6 59.2 58.3 52.5 84 210.1 92.6 66.1 55.1 47.2 41.3 37.3 36.7 33.0 96 73.8 55.3 44.3 36.9 31.6 27.7 25.0 24.6 22.1 108 51.8 38.9 31.1 25.9 22.2 1 19A 17.6 17.3 15.5 Impact Radngs ASTM E1996-Wind Zone 4,Missile Level D PWAS 201/203-Large Missile and Small Missile compliant Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 Phone:717.932.8500 www.keystonecerts.com oNE Appendix 1 Expiration 9/W 13 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tabbs for the: 45 Degree Bay/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:45 Deg. -ONE-WAY MULLIONS SPAN TRIBUTARY WIDTH W IN. (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 192.2 180.0 174.1 173A 171.1 72 200.0 165.8 136.1 117.0 104.2 95.4 90.1 1 89.4 85.5 84 135.4 103.1 84.1 71.7 63.2 57.1 53.2 52.7 49.5 96 90.3 68.5 55.6 47.2 41.3 37.0 34.3 33.8 31.4 108 63.2 47.9 38.7 32.7 28.5 25.5 23.4 23.1 21.3 DESIGN PRESSURE LIMITS FOR MULLION:45 Deg. -TWO-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W(IN.) (IN.) 18 C200.0200.0 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 187.5 184.5 166.0 48 200.0 200.0 177.9 155.7 140.6 138.4 124.560 200.0 166.0 142.3 124.5 112.5 110.7 99.6 72 200.0 105.6 90.5 79.2 71.6 70.4 63.4 84 133.0 99.8 79.8 66.5 57.0 49.9 45.1 44.3 39.9 96 89.1 66.8 1 53.5 44.6 38.2 33.4 30.2 29.7 26.7 108 62.6 46.4 37,6 31.3 26.8 23.5 21.2 20.9 18.8 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certification,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 Phone:717.932.8500 www.keystonecerts.com � ) Appendix 1 CAR No:622-104.0 �ICEYS'TONE e_it------1-f Expiration Date:9/22/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 90 Degree Bay/Bow Aluminum Mullion DESIGN PRESSURE LIMITS FOR MULLION:90 Deg. -ONE-WAY MULLIONS SPAN'L' TRIBUTARYWIDTH'W' IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 199.2 72 2D0.0 200.0 200.0 184.5 167.4 155.7 148.6 147.6 142.3 84 200.0 183.3 149.5 127.5 112.3 101.5 94.6 93.6 87.9 96 160.5 121.8 98.9 83.9 73.4 65.8 60.9 60.2 S5.9 108 112A 95.1 68.9 S8.2 50.7 45.2 41.6 41.1 37.9 DESIGN PRESSURE LIMITS FOR MULLION:90 Deg. -TWO-WAY MULLIONS SPAN TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 197.5 184.5 166.0 48 200.0 200.0 200.0 200.0 177.9 155.7 140.6 138.4 124.5 60 200.0 200.0 199.2 166.0 142.3 124.5 112.5 110.7 99.6 72 1 200.0 200.0 166.0 138.4 118.6 103.8 93.8 92.2 83.0 84 200.0 277.3 141.9 118.2 101.3 88.7 80.1 78.8 70.9 96 158.4 118.8 95.0 79.2 67.9 59.4 53.7 52.8 47.5 108 111.2 83.4 66.7 55.6 47.7 41.7 37.7 37.1 33.4 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-large Missile and Small Missile compliant Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etter$,PA 17319 Phone:727.932.8500 www.keystonecerts.com 3 � 6 }aM still ca WA to twots 9, N = lit , �tl SN wt-' � ` N i O fill iA m WO z � t lop I � I go � n wi � try �IAh W� 3 — ■ ` g — — Z O • �i Q� . J• 3� jr ,•aaaaa�,�-y"�Iy,'������ii NNN �W ygy ��N trt It it I ? -- - Z Oil • ---- 3� ---- ---- 7 � 0 | � | , � ! • � � to k 4LK | � IN | , � | n § q � ilgi §| - � !�� ! ■2 a - | � � ■ � � ® . � ��f�� UA ` •|||| ■ ;; -||§■§■� § | •|||§■§■■ § •|§■§■�■; � | ||°| ■§■; ||§■ -`■; 2 $;-||||■;■; K|-||�§■§;■ § ° � || | )|�■h�§�� �■��§§R�■ « �\7 , e �|•■■|§■■�; � •■■|g�■■ � � ,| A | •||||§■■; | • |§§�■] ) | •|| |�■�■ •| -||§■■■ | -■|||E2■; •|IMP; §. ..,. �..■ §.....�..■ IV _! kF z a ' 01 a *1 `:l �<< l� ^ td$ IL Z FR Lai N of i d d C < y o �liaa�W�.a..�. eae�ama�eA x�ag�� aaa ia����aaa a�ryaaaaga��a o�nasaagaya��� a IL I�� iaaaa��CM •aaaaa� � .. o 0 is as -�a iaaaaaa i � e o � �a aaaa�� � aaaaaaa � N N � 'ii7BF'ii�} asi7&89Ri �! . � • � % � � � � � � � ■ IA ' § e 2 k ■ ; q | | f ' 2 § � k � � � \ ■ ,a� | | � § � | � � �q q ■ § | \ oil * . % 2 , N ■ B § A l It Rip | . ' ■ ! \ | � � � « I - , $ | . .. , / 1 � ■§2 q■■|' | ■ 3 B a w � •||■E ;■; -■ § ■■ ;■ ' | •||■h■■; | •h�2■§; | ||■||■■§� | | ■! ■2�; ��-||■|§§■§ $| § a|q||■■■gM |-||§M M § ° j �•|■�a � ||�|||���■ § q@q - | •|||■|� § | -|||■■§■■ § |� | •|||||§§� | •|||||B|■ % , | •|||■||■] | •| #|°|£2 c E,..,.�..■ §...,.�. .■ �i lk \ � 8 Z+ %it M 7 5 Its W 3 ach Blvd. n BUILDING DROPS 398EastDaniaBeSuite3 Suite 338 • Dania Beach,FL 33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@ buildingdrops.com Product Evaluation Report Of Eastern Architectural Systems, Inc. HVHZ Clipped Aluminum Bay/Bow Mullions for Florida Product Approval FL# FL17472 Report No. 3286 Florida Building Code 2010 & Vh Edition Per Rule 61G20-3 Method: 1 —A(Certification) Category: Windows Sub —Category: Mullions Product: SVMZ Clipped Aluminum BayBow Mullions Material: Aluminum 600S-T5&6063-T6 Prepared For: Eastern Architectural Systems 10030 Bavaria Road Ft Mvers, FL 33913 Prepared by: ���•�,��. •.. -�' '% . r ;' 'P Bermes F. Nmero, P.E. • a 7 _ Florida Professional Engineer#73778 Date:02/27/15 Evaluation Report Pages 1-4 *"i'-'/pNAL�a����` Digitally signed by Hermes F.Norero,P.E. �rrrrrtnttttt�� Reason:I am approving this document Hermes F.Norero,P.E. Date:2015.02.2812.39:04-05'00' Florida No.73778 BUILDING DROPS FL#h FL17472 • A Perfect Solution In Every Drop Date: 02/27/15 Report No: 3286 Certificate of Authorization:29578 Manufacturer. Eastern Architectural Systems,Inc. Product Category: Windows Product Sub-Category: Mullions Compliance Method: State Product Approval Rule 61G20-3 Product Name: HVHZ Clipped Aluminum Bay/Bow Mullions Scope: This is a Product Evaluation Report Issued by Hermes F.Norero,P.E.(FL#73778)for Eastern Architectural Systems,Inc.based on Rule Chapter No.61G20-3,M2Lh9d la of the State of Florida Product Approval,Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the 2010&St'Edition Florida Building Code. See Installation Instructions PA-0004,signed and sealed by Hermes F.Norero,P.E.(FL#73778)for specific use parameters. Umks of Use: 1. This product has been evaluated and is in compliance with the 2010&5'h Edition Florida Building Code,including the'High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used In areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2010&S'Edition Florida Building Code and does not require an impact resistant covering. Individual window units must be impact rated where applicable. 4. Site conditions that deviate from the details of drawing PA-0004 require further engineering analysis by a licensed engineer or registered architect. S. All configurations shown in installation instructions PA4)004 have been qualified as required by section 1715.5.5 of the 2010 FBC and section 1710.5.3 of the S"Edition FBC. 6. See Installation Instructions PA-0004 for size and design pressure limitations. Hermes F.Norero,P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS FL*t FL17472 k A Perfect Solution In Every Drop Date: 0 o: 328 Il CeMRate of Authorization:29578 Report No: 286 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3 for manufacturing under a Certification Agency through Keystone Certifications,Inc.(FBC Organization#:CER1523). Referenced Code Sections: 1. 1715.5.5 of the 2010 FBC 2. 1710.5.3 of the 51"Edition FBC Referenced Data: 1. Product Testing performed by: Certified Testing laboratories (FBC Organization#:TST1577) Report#:CTLA 301OW-4 Report Date:07/18/14 Report#:CTLA 3010W-4A Report Date:07/18/14 Report#:CTLA 301OW-5 Report Date:07/18/14 Report#:CTLA 301OW-SA Report Date:07/18/14 Report#:CTLA 301OW-6 Report Date:07/18/14 Report#:CTtA 3010W--6A Report Date:07/18/14 Report M CTLA 301OW-7 Report Date:07/13/14 Report#:CTLA 3010W-7A Report Date:07/18/14 Report#:CTLA 301OW-10 Report Date:09/22/14 Report#:CTLA 3010W-10A Report Date:09/22/14 2. Certification Agency Keystone Certi iatiorrs,Inc. (FBC Organization#:CER1523) Hermes F.Norero,P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS FLO: FL17472 • A Perfect Solution in Every Drop Date: O Report Noo:: 328286 CertBkate of Authorization:29578 Installation: 1. Approved anchor types and substrates are as follows. A. For two by(2X)wood frame substrate,use 914 Wood Screw type wood frame anchors of sufflclent length to achieve minimum embedment of 1.50"into wood framing. B. For concrete or masonry substrate where one by(M),non-structural,wood bucking is employed,use 1/4"diameter ITW Topcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed,use 1/4" diameter fMl Tappan type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For metal stud substrate,use 1/4"Grade S self-drilling screw type metal frame anchors of sufficient length to achieve a minimum three threads penetration beyond metal structure. Refer to Installation Instructions(PA-0004)for anchor locations,design load tables,and further details of the installation requirements. Design Pressure: See drawing PA-0004 for mullion desirg pressure tables,mullion profiles,and Installation detalls. Hermes F.Norero,P.E. Florida No.73778 Page 4 of 4 12115/2017 Florida Building Code Online II /fessinal Regulation �.-... Business • 1 BCIS Mome Lop In user eeplatrauan eot Toplo Submit Surcharge SW$B Fads Pubil.Uons FSC Staff MS Ste Map Unka Search /y pr ProducticUPU USSR: DII<User Prop me Aooroval Menu>Pr 4 ct p,Apalicatm Search>Aoal canon List>1lppli"U.pefall FLY FLvision RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair bivd tampa, FL 33610 (513)284-0129 danoChstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 3. King,P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL16651.RS CDI fbl Certificate of Independence odf Referenced Standard and Year(of Standard) Standard Year AAMA/W DMA/CSA301/I.S.2/A440 2011 AAMA/W DMA/CSA301/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code https:lMoridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQWtDgtmmTSTNdVPsacfoLiCDIJOgiPTY%21Rt2LFFzMPBymMMOQ%3d%3d 1/5 12/15/2017 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/1Z/2017 Date Validated 1 0/2 712 0 17 Date Pending FBC Approval 10/29/2017 Date Approved 12/12/2017 Summary of Products Go t0 Page v 0 Page 1/2 0 0 FL R Mode4 Number or Name Description 16851 1 _ a.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung TIR Window New Construction with Nall Fin(O/X-configuration) Limits of Use InstalNrtlon Instructons Approved for use in HVHZ: No FL16851 R5 II (b)Inst 16851.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.1 for Design Pressure Ratings,any FL16851 R5 AE (bl Eval 16851.1 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.2 b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with Flange(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R5 11 (b)Inst 16851.2 odf Approved for use outside HVHZ.•Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.2 for Design Pressure Ratings,any FL16851 RS AE (b) Eval 16851.2.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.3 c.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New Construction with Nail Fin(0/X-configuration) Limits of Use _ Installation Instructions _ Approved for use in HVHZ: No FL16851 R5 II (b)Inst 16851 3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: See INST 16851.3 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851.3.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes Particulars. 16851.4 d.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Titt Window with Flange (O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16851 R5 11 (b)Inst 16851.4.odf '. Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,RE.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.4 for Design Pressure Ratings,any FL16851 RS AE (b) Eval 16851 4.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16B51.5 e.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window New Rated-HVHZ Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:Yes F 16851 R5 11 (b)Inst 16851.5.odt Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.5 for Design Pressure Ratings,any FL16851 RS AE (bl Eval 16851 5.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes Particulars. 16851.6 f. 94SO Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window with Flange Rated-HVHZ _ 1(O Limas /X configuration) il- of Use ImrteNotion Instructions https://floridabuilding.org/pr/pr_app_dtl.aspx?param-wGEVXQwtDgtmmTSTNdVPsadoLiCDIJOgiPTY k21Rt2LFFzMP8ymMmOO/3d k3d 2/5 12/15/2017 Florida Building Code Online Approved for use in HVHZ:Yes FL1051 95 11 (b)Inst 16851.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.6 for Design Pressure Ratings,any FL16851 R5 AE (b) Eval 16851.6.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions - -�— -_ Approved for use In HVHZ:No FL16851 R5 11 to Inst 16851.7.odt Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.7 for Design Pressure Ratings,any FL16851 RS AE (b)Eval 16851.7.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.8 'h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with Flange (O/X-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R5 11 (b)Inst 36851.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.8 for Design Pressure Ratings,any FL16851 RS AE (b) Eval 16851 8.odf Additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, 16851.9 r.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New Construction with Nail Fin(O/X-configuration) Limits of Use InetsBation Instructions Approved for use in HVHZ: No FL16851 RS 11 (b)Inst 16851 o odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.9 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851 9 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.10 j,4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window with Flange(O/X -configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R5 II to)Inst 16851 10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.10 for Design Pressure Ratings,any FL16851 R5 AE (b) Eval 16851 10 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.11 k.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window New Rated-HVHZ Construction with Nall Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 RS 11 (b)Inst 16851 13 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,RE.43409 Impact Resistant: Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: See INST 16851.11 for Design Pressure Ratings,any FL16851 RS AE (b) Eval 16851 11 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. i 16851.12 1,4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window with Flange(O/x Rated-HVHZ configuration) Limits of Use - Installation Instructions Approved for use in HVHZ:Yes FL16851 RS II (b)Inst 16851 12 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F,Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A ;Evaluation Reports Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R5 AE f bl Eval 1685 r 12 pd additional use limitations,installation instructions and product Created by Independent Third Parry:Yes particulars. �l 16851.13 in.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin(O/X 1 DIX-configuration) https://floddabuilding.org/pr/pr app_ fl.aspx7param=wGEVXOwtDgbnmTSTNdVPsacfoLiCDIJ09iPTY%2fRt2LFFzMP8ymMMOQ%3d%3d 315 1211t5P2017 Florida Building Code Online Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R5 11 (b)Inst 16851 13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.13 for Design Pressure Ratings,any FL16851 R5 AE (bl Eval 16651.13.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.14 n.4000 Twin Single Hung Window Extruded Vinyl"Non Impact`TWIn Integral Mulled Common Jamb Single Hung Window with Flange(O/X I O/X- configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R5 11 (b)Inst 16851.14.cdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R5 AE fb)Eval 16651.14.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.35 To. 4000 Triple Single Hung Window Extruded Vinyl"Non Impact"Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin (0/X I DIX I O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 RS II (b)Inst 16851.15 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.15 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851.15.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window New Construction with Nail Fin(O/X 10-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R5 II (b)Inst 16853 16 odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,RE,43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.16 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851.16 odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16851.17 q.4600 7Win Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window with Flange(O/X 10- configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 RS 11 fb)Inst 16851.17.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports I Other:See INST 16851.17 for Design Pressure Ratings,any FL16851 RS AF (b) Eval 16851.17 odf j additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.18 r.4800 SH/SH/SH -Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (OM I O/X I O/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No L L16851 R5 11 (b)Inst If 851 18 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.18 for Design Pressure Ratings,any FL16851 R5 AE (bl Eval 16851 18 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. III 16651.19 +s.4900 SHISH-Twin Single Hung Extruded Vinyl Integrally Mulled Twin Single Hung Windows with Flange; (O/X I DIX configuration) Limits of Use Installation Instructions I Approved for use In HVHZ:No FL16851 R5 Il (c) Inst 16851 19 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,RE.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.19 for Design Pressure Ratings,any EL16851 RS AE (b) Eval 16851 19 df Created by Independent Third Party:Yes https:/Moridabuilding.org/pr/pr app_dti.aspx?pamm=wGEVXQwtDgbnmTSTNdVPsacfoLiCDIJ(IgiPTY%2fRt2LFFzMPSyMMM00%3d%3d 415 12/15/2017 Florida Building Code Online 1 additional use limitations,installation instructions and product particulars. 16851.20 t 4900 SH/SH/SH.-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (O/X I O/X 1 O/X configuration) Limits of Use Installation Instructions _ Approved for use In HVHZ:No FL16851 RS Il fc)Inet 16851.20.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.20 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851.20.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page 0 0 Page 1/2 0 0 00 contact Us::2601 allay Stone Aced.Tallahassee F.323N phone:850-497-1824 The State of Florida Is an AA/EEO employer.copyright 2O117d013 State of Pofrlda.::Prwacv Statement::AOtessidllry Statement::Refund statement UrMer Florida law,small addresses are public records.If you do not want your a-moll address released In response to a public-records request,do not send electronic mail to ads entity.Instead,canted the office by phone or by tradNonal mall.if you Kaye any questiam,pleae,mntact 850.487.1395.-pursuant to section 455.275(I),Florida Statures,MecHve October 1,2022,licensees Ismased under O,apter 455,P.S.raw pmylde the Department we an email address d they have one-The emells provided may bs used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide Me Department WIN an!mall address whlN can as made ayallabk to me pubic.To determine If you are a scenes under chapter 455,F.5„ passe nick hem. product Approval Accepts: ITILMEE30 Credit Card Sate httpsJ/loridabuilding.org/pr/pr_app_dtl.aspx?param-wGEVXQwtDgtmmTSTNdVPsaefoLiCDIJOgiPTY%2fRt2LFFzMPBymMmOQ%3d%3d 5/5 R w R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Bolt 230 Valeico.FL 335" Place 813.659.9197 Florida Board ofProksus alEnglamsCaufasteofAuftnastionNo.9313 Certificate of Indepmdence RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named in the accompanying Florida Product Approval. 11/9-� Lyndon F.Schmidt,P.E. FL No.43409 October 2,2017 RAA-A Product-Job-Lab-L1stsu-Florida-Product ApptowbU WW Scanned Poatinga W"HoldenlCatif cste of IridepmdatmAw Shea I of 1 w..ox i Ll�ll6'M'tl•I OG° clod 'tlN YO 3dod SNaISV3H N uM-•,^' L616'6co'clo :BN Buoyq 531aN MDN3a 3- 538N693adal 1 31Va ON u .J NW30 Naf1YA3L3 TIJIdA! C6oCC v 'tlBII NW toe 'O'q Sfi OBd t10Z Q3 Hlf O1 31YOda sl 92 8 l ']NI '61NV11I16N0'J IXlgllfl6 Q7 �A1B11355V tl0 INLd Nf lIYl30 OHIZYIO 0 1 1 Z `\\\\\11111111IfL'/,/ �Yct .oN 3-d Sfi �3M MWNW Z9 LC 03 ZI tt Z t N Z [ B4 .,.• 7y/.., \tl m4�5 '! tltlVN61 MWNIM 9NOH TOMS pf pfl1 bOt 03 N{B OL 3lMdll LI BO 01 c �+ `� y 3 �::K B•.!w.w�°ad �1]11Wad 3 (1 E E 100 - eorcr'BN ; 0 0 Z G c e e 5 N •�O m �i � m � � 3 h k � Ix _Ali Q n T X X 5 b b v W`JBH 3WOtl XV1.91 WfJBH 30NYU TIYN3N07W11L rz M 3 c o < $ 0 rp 1,45 W - ° n a ui s v a Q O E & u o m8 amp mil aQ6 \\\ a E �O + O Q cV a E >i> 1> �1 F� a n gm .a-0 co m fs a Fa ,i kzo 5Zo E V ` m ' o » UFB 95 yy N C1 O N 915691'li 4W 9ISc911lNLIOi11599['lf\s6u!Mtq-r6unN oMN51569f1fkRpMtly Vnp�tl rywN YUN3NtlXp3!>MOP4M U^^5*\NV1uiq\Y MAMA ar'Qn O O O O A ©O 1\-1i a Y•� = --T�'. f����i oil m I 0 O O �•� I hI j Q�Q� O C•.1-M14?1F•:J „ Fr7E"fQi3C7'«iE7^�7M177170 •.r E.1i k r ,7'.�7mL�� .. irjgz O O , ,.��� � ��_ I�� a �r • O A • © ��I�il O �����1 O i �F 4�4� ^ �yMpa ull.6 •1'Y YIY-a fe O two u{awe{a rwl www 31Wa!ww 7MB awes v wm W9 a•a yr =1.4 { • E E �� vwnxawaa anaa{{a { { � +a,•11S{II{Iiip��,'i'4 yMy�a,�.wowl wow sm 3mm. IM-N MPFO y`�`���,• ��•4hn{{N••`" • �� � �r�� � �rutl l !___ �r W �r � is 16 $ ` is •� � a a M....u�rt•Wiim,amv�-�°w'.aaw,{.U*�^m+p"P°n'^"'-wrw�+�-°o�w{ws•K.w.r1« wi�unis.m�we++r•�•��cos p am w Y`O]/I L/akvm00 'JM 'iYNl�NMCp ONRIIMnmwwwt [ ^1 S `III/f11111111/11 L = p 1j'6 www v�wuti Wo MOON 'mm you w' 1 Y t l LIW'df wppp 'IIIIIIIIIIIIIIIII,� L'1 A e �� a p h^A•1� p ¢ sm3ma A MCI 1 � LL a siz El r-1 ►�:I�i�Cr�i•;I N y,� _ "� �vlF:_T_Vi[`�Y7��L•T€�+�:'�Ti�i M - lllll • � � L L i L t L f L ( Y /r L � f • �• • • �• a •• L L y L l L L L L L � . f • L f L 1� • L e • y l �. 1♦ �� l J nr F�' 'A � � � s' •� F� h, BCC©O��o0000oC0000C9�8999�6�6 R R W Building Consultants, Inc. W Consulting and Engineering Services for the Building Industry B P.O Box 230 Valnco.rL 33395 Photo 813.659.9197 CFlorida Board of Professional Engineers Certificate of Aumorimtlon No 9813 Date: October 1!,2017 Product Category Sub Category Manufacturer Product Name NewSouth Window Solutions 9460 Single Hung Window Windows Single Hung 4901 Oak Fair Blvd Impact Rated-HVHZ Tampa,FL 33610 wl Flange a13 62" 00 Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.B1G20-3,Method 1 D of the State of Florida Product Approval, Dept.of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the 'HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16851.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16851.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Sioned by C9937.03401-18 TAS 201,202,203-94 Architectural Testing,Inc. Shawn G.Collins,P.E. TEL 02031487 TAS 201,202.203-94 Testing Evaluation Lab. William S.Shelton,P.E. TEL 02031566 TAS 201.202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. TEL 02031722 TAS 201,202.203-94 Testing Evaluation Lab. William B.Shelton,P.E. 2. Miami Dade NOA Materials Testina 17-0712.05 Saflex•PVB intedayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Stoned&Sealed by No.FL-16851.6 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. ASTM El 300 Glass Load Lyndon F.Schmidt,P.E. `t1111118I/et F5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that NewSouth Window Solutions is manufacturing + No 43?09 products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. 9.1 STATE :0 T O Ly nd onSchmidt.P.E.4"/S/oNA E 10/1212017 Sheet 1 of 1 1211812017 Florida Building Code Online FLOAMA Business & Professional s t �aap�pr.R KIS Home Log In User Registration Hot Topla Submit Surdmrge Stets a Facts Publications Ric Stec acts Sae Map Uni s Search bp dr ®Product Approval USER:Public User Product Aooroval Menu>Prod ct or Appliotion Search>Aoorcation List>Appliwtlaa DOW" FL# FL R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@mbidgconsuttants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 1. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL16842 R4 COI (cl Certificate of lndeoendence odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 AAMA/WDMA/CSA301/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2005 ASTM E1996 2009 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 115 1 2/1 812 01 7 Florida Building Coda online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/11/2017 Date Validated 10/20/2017 Date Pending FBC Approval 10/23/2017 Date Approved 12/12/2017 Summary of Products Go to Page ® 0 0 Page 1/2 0 0 FL S Model,Number or Name Description 16842.1 a.Series 9000 Model 9500 Slider XO Extruded Vinyl'Non Impact"Horizontal Sliding Window utilizing a Nall Fin Installation(XO or OX configurations) Limits of Use Instellation Instructions Approved for use In HVHZ:No FL16842 R4 II (b)lost 16842.1 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INSI 16842.1 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16842.1 odf additional use limitations,installation Instructions and Product Created by Independent Third Party:Yes particulars. 16842.2 b.Series 9000 Model 9500 Slider XO Extruded Vinyl"Non-Impact°Horizontal Sliding Window with Flange Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16842 R4 II (b)Inst 16842 2 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.2 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16l 2 odf additional use limitations,installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.3 c.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a •Impact Rated Nall Fin Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16842 R4 11 (b)Inst 36842.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party; Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.3 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.3.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. ttt 16842.4 it.Series 9000 Model 9550 Slider XO 1 Extruded Vinyl"Impact"Horizontal Sliding Window with Flange -Impact Rated Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16842 R4 11 (b)Inst 16842.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant;Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.4 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16842.4 Ddf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16842.5 e.Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a -Impact Rated-HVHZ Nall Fin Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes F136842 R4 II (b) Inst 161142 5 odl Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16842.5 for Design Pressure Ratings, any t16842 R4 AE (b) Eval 16842 6 odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16842.E f.Series 9000 Modef 9550 Sff XO ;Extruded Vinyl"impact"Horizontal Sliding Window with Flange httpsl/floridabuilding.org/pr/pr_app_dtl.aspx4param=wGEVXQwtDgbnmTSTNdVPSN/o2fLKgxApZZOumXyGur83s42hZkY3sC4ZA%3d%3d 2I5 1211812D17 Florida Building Code Online -Impact Rated-HVHZ Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL16842 R4 II (b)Ins[16842.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.434D9 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports other:See INST 16842.6 for Design Pressure Ratings,any FL16842 R4 AE lb)Eval 16842.6.odf additional use limitations,Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.7 g.Series 9000 Model 9500-3 Slider Extruded Vinyl'Non-Impact-Horizontal Sliding Window XOX utilizing a Nail Fin Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b)Inst 16842 7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,RE.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports other:See INST 16842.7 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842 7.odf additional use limitations,installation inslYuctlons and product Created by Independent Third Party:Yes particulars. 16842.8 h.Series 9000 Model 9500.3 Slider Extruded Vinyl"Non-Impact"Horizontal Sliding Window with XOX Flange Installation(XOX,configuration) Limits of Use Installation InstruWons Approved for use in HVHZ: No FL16842 R4 11 (b)Inst 16842 8 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings,any FL16842 R4 AE (b) Eval 16842.8 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. _ 16842.9 i.Series 9000 Model 9550-3 Slider Extruded Vinyl'Impact'Horizontal Sliding Window utilizing a XOX Impact Rated Nall Fin Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 It (b)Inst 16842.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.9 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.9.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. _ 168a2.10 ).Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window with Flange XOX-Impact Rated Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ:NO FL16842 R4 II (b)Inst 16842.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Repots Other:See INST 16842.10 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842 10 odf additional use limitations, Installation instructions and product Created by Independent Third Party:Yes particulars. 16842.11 k.Series 9000 Model 9550-3 Slider Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a XOX Impact Rated-HVHZ Nail Fin Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16842 R4 II (b) Inst 15842 1l.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports other:See INST 16842.11 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.11.odf additional use limitations,installation instructions and product _ Created by Independent Third Party:Yes particulars. 16842.12 I. Series 9000 Model 9500-3 Slider Extruded Vinyl"Impact" Horizontal Sliding Window with Flange XOX-Impact Rated-HVHZ Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL36842 R4 II (h) Inst 16842.12.odf . Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.434011 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 16842.12 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.12.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. i https:llfioridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZOumXyGur83s42hZkY3sC4ZA%3tl%3d 315 1 211 8/2 01 7 Florida Building Code Online 16842.13 m. DuraGard Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window utilizing a Nall Fin Installation(XX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 H (b)Inst 16842.13 odf Approved for use outside HVHZ:Yes Verified By;Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.13 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.13.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16842.14 n.DuraGard Slider XX I Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R4 11 (b)Inst 16842 14 odf Approved for use outside HVHZ:Yes Verified By;Lyndon F,Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 16842.14 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.14 odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16842.15 o.DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window utilizing a Nall Fin Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16842 R4 11 (b)Inst 16842 15 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.15 for Design Pressure Ratings,any FL16842 R4 AE fbl Eva(16842 IS otl! additional use limitations,installation instructions and product Created by Independent Third Party:Yes Particulars. 16842.16 p•DuraGard-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window with Flange Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 11 (b)Inst 16842 16 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 16942.16 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842 16 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes Particulars. 16842.17 q Sashlke Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window utilizing a Nall Fin Installaton()(X,configuration) Limits of Use Installation Instructions _- - Approved for use In HVHZ:No FL16842 R4 II (b)Inst 16842 17 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16842.17 for Design Pressure Ratings,any FLIU42 R4 AE to)Eva)36842 17 odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars, 16842.18 r. Sashlite Slider XX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No F1.76842 R4 lI (b)Ins116842 18 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, RE.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16842.18 for Design Pressure Ratings,any FL16842 R4 AE fb)Eval 16842 18 odf additional use limitations,installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.19 s.Sashllte-3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window utilizing a Nall Fin Installation(XOX,configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL36842 R4 11 (b) Inst 16842 to odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: See INST 16842.19 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842.19.pdt additional use limitations,installation instructions and product Created by Independent Third Party:Yes Particulars. httpsl/Boridabuilding.org/pdpr_app_dd.aspx4param=wGEVXowtDgtmmTSTNdVPsfh2fLKgXApZZOUmXyGur83s42hZkY3sC4ZA%3d%3d 4/5 12/18/2017 Florida Building Code Online 16842.20 t. Sashlite -3 Slider XOX Extruded Vinyl"Non-Impact"Horizontal Sliding Window(XOX, configuration) L1mRs of Use Installation InstruQions Approved for use In HVHZ: No FL16642 R4 11_(b) Inst 16842 20 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16842.20 for Design Pressure Ratings,any FL16842 R4 AE (b)Eval 16842 20 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page ® 0 0 Page 1/2 0 0 0 Contact Us::2601 aklr Stone Road.Tallahassee Fl-323"Phone:950-or?.1824 The State of Florida is an WEED enno w..COnydpht 2007-2013 State of Flcdda ::Privacy Statement::AIoudial tv statement;;aefund Statement under n Hd,law,smell addresses are public records.If you do not want your a-man address released in response to a pvbpc-records request,do not send e*,mnic mall to this entity.Instead,contact Its,office by phone or by traditional mall.If you have any question,please contact SS0.487.1395JPursuant to section 455.275(1),Florida statutes,effective cooper 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address N they have one.The emails provided may be used for official communication with the ficenses.However email addresses arc public record.If you do not wish to supply a personal address,please pmNde the Department wltb an email address which can be made available to the public To determine N yw we a licensee tinter Chapter 455,F.S., please click b=L. product Apprwval Atimptar ®WI ® ram_ Credit Card Safe https:llfoddabuilding.org/pr/pr_app_dg.aspx?pamm-wGEVXOwtDgtFnmTSTNdVPsfa/a2&KgxApZZOumXyGur83"2hZky3sC4ZA/.3dHa3d 5/5 R W R W Building Consultants, Inc. B Consulting and lingineoring Services for the Building Industry C P.O.Box 230 Valdoc,FL 33595 Phone 913.d59.9197 Florida Bard of Prohs"W FAsWw Cadfmk of Awhaization No.9913 Certificate oflndependenee RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named in the accompanying Florida Product Approval. Lyndon F.Schmidt,P.E. FL No.43409 October 2,2017 RAA-A Product-Job-Lab-L1eta1A-FINWa-Product ApproWfflorWa Sc=W PoatinWlaee HoldaeCati =of indepardemAoc Sboet I of 1 uae '.x YO 3ea!' NOi I N •••••�a.oa .�a,� c .o 0¢Q saION 3YN3N37 w S3N11553dd to le'ero'cw �'^N .9.ud I.8 NDIS30 'NOLLYA373 lbOld{I 31tl ON y b bI SeCtt V 'eaWeA•erZ ma 'S"e M 5/1 Jfli iIOZ 'a3 NLS Ol 3119d11 fl rL 9 I vi '°NI 'aINYPNeNO° °NIQ11Ra eau A19R3551' Lnd >M IZYkI OQI l3pDN 35Wy Sl 2 ``\\\\\11111111I1!Z'' IRwV'+�S '!�Wtll 41no5waN � �tOL bON(AW 1�� et aZ � .t n lw•eoleaewO ;f_ ci llllllll\\, ? O X � ° < � I �.•_.- . 1H06H 3YfV}d'XVW.E9� WORN 30NW 11Ytl3A0 XYW J9 Z ° F 6 it g h R a 9E � x € a e 0 € qq Z eo e a r qg px fn O RG Q 0 E 2p �7Z t°�° .` �� g� �•� 5� y � ss n o oB.e O Z 9[SB91]f E*V92M91'HYLSCi1ZM31'llVeuuu9 ]yaR619wnroX[pe3i'1SVp.W W Unpay apnN-NIN3NtlWtl3tlaW�R"M W^K a`.NVwail]lY i �� - E:]E'-'�-:' r ✓t: i- ..1-_:F�mlI1r31E�1 ° O O OOe ° . OeAeeC ° � o 0 e Qr� Q� �MIYI�'.V vim CLW •a. v.un,.wo.Ne.m� a�'aa'�u I I >Z�' S I lql H, ♦ �Ii AMC♦ 'MIT N E �y iYNMi'/� �WbSMN li LIQ'IO�IYIIoO � �OIOwI ycN� raw we ZZZ u r�w�n-i �'�nlunmxa♦`♦r u � e raw we . S •M.tlm . A p • v Y ~ tl x Y all i N Y N 1 A V h �yip{�r , • Y • �Yi6�3 p a � xaoram•vunm:IscwMr+o•T1EM�AANi8B1-WM�.•YG.Yma-NIIi�/nvlBlvA+IMY.i�tNwldY w�wnnl.riro rwavn�•w•�r iw e U %M41A ^41 r Wd a NKS�pp1111� f1CZ el 1 µt 14 .q\IIIIIIIIIIII 1 �� d 4 NKf 'M1 T/ >W 1 NU f f y OWR'�WpM1 Cneyty � p y 4 7 LIDE'YOni�O ! S Rongowky Il�minuatt"� taw L—� srrwzl h_ r p \C L� r raw raw'o'o � mwa L = a a � ', , : , 1 11f$it Y � E o N M 'WI YMaV1�lY0 w1iY1n�'M'Y♦,.a CIM •MI YD]N/' atelamw NN ww lam I `„U1UUUgr r4 �Wlt �Il T k L s uatrroo.wro tez� si--{ �.cri----i rlpr4tells Zr'1 I qC3 ILI1 . $ xt u ,00 saa 4. �ro • N O N � L � s L�Cz7 � L b d 'Onl YYI�J1MVMp)YNT�n['M'Y�lOt � jwo ' e a twaYSYoo a[m[r ,UpuIM L1WVDAQM i bl, A - - - it _ - -� - k ix so, R a � e � OUO W w.�K�^NVJftlVhOPR�S' � ^^Op F fl�ilOU['1/UiTTb OtlI'INOM�O'�Mi/MSWI WWWWWOSPV��[MPioYMY41•W191111BIYYPYYYYRY�M�l11 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C VC,Box 230 Valnco,FL 33595 Phone 913 659,9197 Flonds Board of Professional Engineers Certificate of Authomalion No.9813 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions Series 9000 Model 9550 Slider XO Windows Horizontal Slider 49D7 Oak Fair Blvd Impact Rated-HVHZ Tampa,FL 33610 wl Flange 813 626.6000 Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt, P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.61G20-3, Method 1D of the State of Florida Product Approval, Dept.of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. UmHations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind bome debris protection,this product complies with Section 1609.1.2.2& R301.2.1.2.1.of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R3011.2.1.2.1. S. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-16842.6 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets water infiltration requirements for"HVHZ". 8. See drawing FL-16842.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02031488 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton.P.E. TEL 02031489 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. TEL 02031566 TAS 201.202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. 2. Miami Dade NOA Materials Testing 17-0712.04 SaBex•PVB Intedayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-16842.6 RW Building Consultants, Inc.(CA#9813) ��01SCyl�to 4. Lyndon F. Schmidt, P.E. 4. Calculations Prepared by `��� V;•DOE NSF•T 0ei� Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) - Lyn n F.Schmidt,P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. No 43409 ••; 5. Quality Assurance Certificate of Participation issued by National Accreditation and :Gl Management Institute,certifying that NewSouth Window Solutions is p••, STATE OF Lyndon F.Schmidt,P,E. ,� ..Ao p;•� FL PE No.43409 manufacturing products within a quality assurance program that complies �� .4 O PI t O••- �` with ISOIIEC 17020 and Guide 53. Sheet 1 of 1 ���5 .......... r1���` 10l12/2017