Loading...
HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: MARK&THERESA ORTOLANI Wind Zone: 170 MPH. Address: 13208 OKEECHOBEE RD Exposure Category: C FORT PIERCE,FL 34945 Minimum Building Dimension: 37 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negativc J Number Zone Width(in) Height(in) Elevation(ft) [Pressure(psf) Pressure(psf) 1 Int 35 35 7 37.8 -41.0 2 Int 51 35 7 37.3 -40.5 3 End 51 36 7 37.2 -49.4 4 End 51 35 7 37.3 -49.6 5 Int 26 49 7 37.8 -41.0 6 Int 26 49 7 37.8 -41.0 7 Int 26 49 7 37.8 41.0 8 Int 26 49 7 37.8 -41.0 9 End 52 49 7 36.4 -47.8 10 End 52 49 7 36.4 -47.8 11 Int 36 36 7 37.8 -41.0 12 Int 36 20 7 37.8 -41.0 13 Int 36 20 7 37.8 41.0 14 Int 36 20 7 37.8 -41.0 15 End 36 20 7 37.8 -50.6 16 Int 36 54 7 37.1 40.3 17 Int 36 54 7 37.1 -40.3 18 Int 36 54 7 37.1 -40.3 19 End 36 54 7 37.1 -49.1 20 End 35 20 7 37.8 -50.6 21 Int 35 20 7 37.8 -41.0 22 Int 35 20 7 37.8 41.0 23 Int 35 20 7 37.8 -41.0 24 End 35 54 7 37.1 -49.3 25 Int 35 54 7 37.1 -40.3 Page 1 of 2 PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: MARK&THERESA ORTOLANI Wind Zone: 170 MPH. Address: 13208 OKEECHOBEE RD Exposure Category: C FORT PIERCE,FL 34945 Minimum Building Dimension: 37 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device IFDevice IFDevice Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 26 Int 35 54 7 37.1 -40.3 27 Int 35 54 7 37.1 -40.3 28 Int 34 20 7 37.8 -41.0 29 Int 34 54 7 37.2 40.4 30 Int 36 20 7 37.8 41.0 31 Int 36 20 7 37.8 -41.0 32 Int 36 55 7 37.0 -40.2 33 Int 36 55 7 37.0 40.2 34 Int 36 20 7 37.8 41.0 35 Int 36 20 7 37.8 -41.0 36 Int 36 55 7 37.0 -40.2 37 Int 36 55 7 37.0 -40.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 2 of 2 WINDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER +� PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ YM SIZE REQ Y/N/NA 1 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 1 37X72 3505 No No 2 Int window 7/8"Lami IG FL16736.1 60 60 37.3 -40.5 74 x 63 5105 No No 3 End window 7/8"Lami 1G FL16736.1 60 60 37.2 -49.4 74 x 63 5106 No No 4 End window 7/8"Lami IG FL16736.1 60 60 37.3 -49.6 74 x 63 1 51 x35 No No 5 Int WindoH va~Lami IG FL6890.1 67.5 67.5 3 7.8 -41.0 3702 26x49 Yes No 6 Int windoH 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No 7 Int Windom 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No 8 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No 9 End window 7/8"L-"G FL16736.1 60 60 36.4 -47.8 74x63 52x49 No No 10 End window 7/8"Lami IG FL16736.1 60 60 36.4 -47.8 74 x 63 52x49 No No 11 Int window 7/8"Lam"G FL6890.1 67.5 67.5 37.8 -41.0 37X72 3606 No No 12 Int window t"Lami IG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No 13 Int WINDOW I"LAMI IG FL 13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No 14 Int WINDOW I"LAMI IG FL 13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No 15 End WINDOW I"LAMI IG FL13010.4 55 55 37.8 -50.6 48 x 72 36x20 Yes No 16 Int window 7/8"LamilG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No 17 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No 18 Int window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No 19 End window 7/8"Lami lG FL6890.1 67.5 67.5 37.1 -49.1 3702 36x54 Yes No 20 End WINDOW I"LAMI IG FL13010.4 55 5537.8 -50.6 48x72 35x20 Yes No 21 Int window V Lami IG FL 13010.4 55 5-5 37.8 -41.0 4802 35x20 Yes No 22 IntWINDOW I"LAMI IG FL 13010.4 5 5 5 5 3 7.8 -41.0 48 x 72 35x20 Yes No WINDOW i • • ' OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+) PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 23 Int WINDOW I"LAMI IG FL13010.4 55 55 37.8 -41.0 48 x 72 35x20 Yes No 24 End Window 78"LmiIG FL6890.1 67.5 67.5 37.1 -49.3 3702 35x54 Yes No 25 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 35x54 Yes No 26 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 35x54 Yes No 27 Int Window 78"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 1 35x54 Yes No 28 Int WINDOW I"LAMIIG FL13010.4 55 55 37.8 -41.0 48 x 72 34x20 Yes No 29 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.2 -40.4 3702 34x54 Yes No 30 Int WINDOW I"LAMIIG FL13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No 31 Int WINDOW I"LAM" FL13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No 32 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No 33 Int Window 7/8"Umi1G FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No 34 Int Window V L-i IG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No 35 Int Window I"I.amiIG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No 36 Int Window 18"LamiIG FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No 37 Int Window "g"Lami`G FL6890.1 67.5 67.5 37.0 -40.2 37x72 36x55 Yes No