HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time"
SCC131150472
Property Information Building Information
Owner: MARK&THERESA ORTOLANI Wind Zone: 170 MPH.
Address: 13208 OKEECHOBEE RD Exposure Category: C
FORT PIERCE,FL 34945 Minimum Building Dimension: 37 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negativc J
Number Zone Width(in) Height(in) Elevation(ft) [Pressure(psf) Pressure(psf)
1 Int 35 35 7 37.8 -41.0
2 Int 51 35 7 37.3 -40.5
3 End 51 36 7 37.2 -49.4
4 End 51 35 7 37.3 -49.6
5 Int 26 49 7 37.8 -41.0
6 Int 26 49 7 37.8 -41.0
7 Int 26 49 7 37.8 41.0
8 Int 26 49 7 37.8 -41.0
9 End 52 49 7 36.4 -47.8
10 End 52 49 7 36.4 -47.8
11 Int 36 36 7 37.8 -41.0
12 Int 36 20 7 37.8 -41.0
13 Int 36 20 7 37.8 41.0
14 Int 36 20 7 37.8 -41.0
15 End 36 20 7 37.8 -50.6
16 Int 36 54 7 37.1 40.3
17 Int 36 54 7 37.1 -40.3
18 Int 36 54 7 37.1 -40.3
19 End 36 54 7 37.1 -49.1
20 End 35 20 7 37.8 -50.6
21 Int 35 20 7 37.8 -41.0
22 Int 35 20 7 37.8 41.0
23 Int 35 20 7 37.8 -41.0
24 End 35 54 7 37.1 -49.3
25 Int 35 54 7 37.1 -40.3
Page 1 of 2
PARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time"
SCC131150472
Property Information Building Information
Owner: MARK&THERESA ORTOLANI Wind Zone: 170 MPH.
Address: 13208 OKEECHOBEE RD Exposure Category: C
FORT PIERCE,FL 34945 Minimum Building Dimension: 37 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device IFDevice IFDevice Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
26 Int 35 54 7 37.1 -40.3
27 Int 35 54 7 37.1 -40.3
28 Int 34 20 7 37.8 -41.0
29 Int 34 54 7 37.2 40.4
30 Int 36 20 7 37.8 41.0
31 Int 36 20 7 37.8 -41.0
32 Int 36 55 7 37.0 -40.2
33 Int 36 55 7 37.0 40.2
34 Int 36 20 7 37.8 41.0
35 Int 36 20 7 37.8 -41.0
36 Int 36 55 7 37.0 -40.2
37 Int 36 55 7 37.0 -40.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 2 of 2
WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER +� PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ YM
SIZE REQ Y/N/NA
1 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 1 37X72 3505 No No
2 Int window 7/8"Lami IG FL16736.1 60 60 37.3 -40.5 74 x 63 5105 No No
3 End window 7/8"Lami 1G FL16736.1 60 60 37.2 -49.4 74 x 63 5106 No No
4 End window 7/8"Lami IG FL16736.1 60 60 37.3 -49.6 74 x 63 1 51 x35 No No
5 Int WindoH va~Lami IG FL6890.1 67.5 67.5 3 7.8 -41.0 3702 26x49 Yes No
6 Int windoH 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No
7 Int Windom 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No
8 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.8 -41.0 3702 26x49 Yes No
9 End window 7/8"L-"G FL16736.1 60 60 36.4 -47.8 74x63 52x49 No No
10 End window 7/8"Lami IG FL16736.1 60 60 36.4 -47.8 74 x 63 52x49 No No
11 Int window 7/8"Lam"G FL6890.1 67.5 67.5 37.8 -41.0 37X72 3606 No No
12 Int window t"Lami IG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No
13 Int WINDOW I"LAMI IG FL 13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No
14 Int WINDOW I"LAMI IG FL 13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No
15 End WINDOW I"LAMI IG FL13010.4 55 55 37.8 -50.6 48 x 72 36x20 Yes No
16 Int window 7/8"LamilG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No
17 Int window 7/8"Lami IG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No
18 Int window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 36x54 Yes No
19 End window 7/8"Lami lG FL6890.1 67.5 67.5 37.1 -49.1 3702 36x54 Yes No
20 End WINDOW I"LAMI IG FL13010.4 55 5537.8 -50.6 48x72 35x20 Yes No
21 Int window V Lami IG FL 13010.4 55 5-5 37.8 -41.0 4802 35x20 Yes No
22 IntWINDOW I"LAMI IG FL 13010.4 5 5 5 5 3 7.8 -41.0 48 x 72 35x20 Yes No
WINDOW i • • ' OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+) PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
23 Int WINDOW I"LAMI IG FL13010.4 55 55 37.8 -41.0 48 x 72 35x20 Yes No
24 End Window 78"LmiIG FL6890.1 67.5 67.5 37.1 -49.3 3702 35x54 Yes No
25 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 35x54 Yes No
26 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 35x54 Yes No
27 Int Window 78"LamiIG FL6890.1 67.5 67.5 37.1 -40.3 3702 1 35x54 Yes No
28 Int WINDOW I"LAMIIG FL13010.4 55 55 37.8 -41.0 48 x 72 34x20 Yes No
29 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.2 -40.4 3702 34x54 Yes No
30 Int WINDOW I"LAMIIG FL13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No
31 Int WINDOW I"LAM" FL13010.4 55 55 37.8 -41.0 48 x 72 36x20 Yes No
32 Int Window 7/8"LamiIG FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No
33 Int Window 7/8"Umi1G FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No
34 Int Window V L-i IG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No
35 Int Window I"I.amiIG FL13010.4 55 55 37.8 -41.0 4802 36x20 Yes No
36 Int Window 18"LamiIG FL6890.1 67.5 67.5 37.0 -40.2 3702 36x55 Yes No
37 Int Window "g"Lami`G FL6890.1 67.5 67.5 37.0 -40.2 37x72 36x55 Yes No