HomeMy WebLinkAboutWind Load Calculation 49c"(0
( Donnell
Impact Windows &
Storm Protection
Lic#:CRC1331273
6401 SE Federai Highway PH:772-40&0200 IMM US Highway i
Stuart,FL 34997 FAX( 88&833-0167 Stuart,FL 34994
Property Information Building Information
Owner: McCurdy Wind Zone: 160 MPH.
Address: 9417 S Ocean Dr Exposure Category: D
Jensen Beach,FL 34957 Minimum Building Dimension: 3 ft.
Mean Roof Height: 30 ft.
AL Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) L.Pressure(psf) Pressure(psf)
1 Int 26 36 7 45.8 -49.7
2 Int 96 80 7 40.9 -44.7
3 Int 26 24 7 45.8 -49.7
4 Int 72 34 14 44.3 -48.1
5 Int 36 48 14 45.3 -49.2
6 Int 36 48 14 45.3 -49.2
7 Int 7 45.3 -49.2
♦♦o%
♦ ,
R
40 N 8 736
FIL I * -
� -
IVIG.R 3.` � TAT F �
p 0' A% �V\�
ST. Lucie County, Permitting i ♦,%
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of I