Loading...
HomeMy WebLinkAboutWind Load Calculation 49c"(0 ( Donnell Impact Windows & Storm Protection Lic#:CRC1331273 6401 SE Federai Highway PH:772-40&0200 IMM US Highway i Stuart,FL 34997 FAX( 88&833-0167 Stuart,FL 34994 Property Information Building Information Owner: McCurdy Wind Zone: 160 MPH. Address: 9417 S Ocean Dr Exposure Category: D Jensen Beach,FL 34957 Minimum Building Dimension: 3 ft. Mean Roof Height: 30 ft. AL Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) L.Pressure(psf) Pressure(psf) 1 Int 26 36 7 45.8 -49.7 2 Int 96 80 7 40.9 -44.7 3 Int 26 24 7 45.8 -49.7 4 Int 72 34 14 44.3 -48.1 5 Int 36 48 14 45.3 -49.2 6 Int 36 48 14 45.3 -49.2 7 Int 7 45.3 -49.2 ♦♦o% ♦ , R 40 N 8 736 FIL I * - � - IVIG.R 3.` � TAT F � p 0' A% �V\� ST. Lucie County, Permitting i ♦,% Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of I