Loading...
HomeMy WebLinkAboutWind Load Calculation Don ncl I Impact Windows & Storm Protection Lic#:CRC1331273 6402 SE Federal Highway PH:772-408.0200 40 US Highway 1 Stuart,FL34997 FAX 888-833-0167 Stuart,FL 34994 Property Information Building Information Owner: Difruscio,Fred Wind Zone: 160 MPH. Address: 3200 Twin Lakes Ter Exposure Category: D Unit 205 Minimum Building Dimension: 3 ft. Fort Pierce,FL 34951 Mean Roof Height: 30 ft. JIL Risk Category: Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number IL Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 141 80 14 39.7 -43.6 2 Int 72 80 14 41.7 -45.6 3 Int 141 80 14 39.7 -43.6 4 Int - 141 80 14 39.7 -43.6 5 Int 7 39.7 -43.6 fill pN H ., RECEIVED • '•' 073 MAR 26 ?018 = i � s ST. Lucie County, Permitting i ii •. ( O Q`• % . .•.•.........I** Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1