HomeMy WebLinkAboutWind Load Calculation Don ncl I
Impact Windows &
Storm Protection
Lic#:CRC1331273
6402 SE Federal Highway PH:772-408.0200 40 US Highway 1
Stuart,FL34997 FAX 888-833-0167 Stuart,FL 34994
Property Information Building Information
Owner: Difruscio,Fred Wind Zone: 160 MPH.
Address: 3200 Twin Lakes Ter Exposure Category: D
Unit 205 Minimum Building Dimension: 3 ft.
Fort Pierce,FL 34951 Mean Roof Height: 30 ft.
JIL Risk Category:
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number IL Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 141 80 14 39.7 -43.6
2 Int 72 80 14 41.7 -45.6
3 Int 141 80 14 39.7 -43.6
4 Int - 141 80 14 39.7 -43.6
5 Int 7 39.7 -43.6
fill
pN H .,
RECEIVED • '•'
073
MAR 26 ?018 = i
� s
ST. Lucie County, Permitting
i
ii •. ( O Q`• %
. .•.•.........I**
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1