HomeMy WebLinkAboutWind Load Calculation A Dori rid
Impact Windows &
Storm Protection
Lic#:CRC1331273
6402 SE Federal Highway PH:772-408-0200 1740 US Highway i
Stuart,FL 34997 FAX:888-833-0167 Stuart,FL 34994
Property Information Building Information
Owner: Jacques Wind Zone: 160 MPH.
Address: 3200 Twin Lakes Ter#105 Exposure Category: D
Ft Pierce,FL Minimum Building Dimension: 3 ft.
Mean Roof Height: 30 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number IL Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 141 80 7 39.7 -43.6
2 Int 72 80 7 41.7 -45.6
3 Int 141 80 7 39.7 -43.6
4 Int 141 80 7 39.7 -43.6
5 Int 7 39.7 -43.6
�`�QP? VAC S'F•• 9,��i
0 80 3 0
��• • STA E
• T
RECEIVED '
MAR 2 6 2018 110NAI.�EN..��.
ST. Lucie County, Permitting
OPY
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.