THERMEAU models specifications
MOC11CAOurfull range of top-of-the-line products exceeds industry
standards and brings you the best components on the market For
matchless performance,go THERMEAU!
2's
In this table of specifications Prestige model is represented byTH and theS is for
Signature model.
Operating 555 565 S85 5105 /5125 5140A
Specifications TH55 TH65 T H85 TH105 TH125 H140A
P55 P65 PSS P105 P125 P140
Volts 230 230 230 230 230 230
Hertz 60 60 60 60 60 60
Phase 1 1 u 1 1 1 1
C 0 VOjjj,,jjomjressor amps 11.05A 12AA 17.2A 232A 243A 273A
Titanium Titanium Titanium Titanium Titanium Titanium
r-�anger /PVC /PVC /PVC /PVC /PVC /PVC
= 1LE Fan motor max. 2 4A 2 4A 2 4A 2-4A 24A 24A
load amps
RECEIVED Fan motor HP_ 1/3 1/3` 113 1/3 1/3 1/3
Fan motor speed 825 RPM 825 RPM 825 RPM 825 RPM 825 RPM 825 RPM
APR 0 2018 Minimum circuit ampacity 30A 30A 30A 40 A 40 A 50 A
ST. Lucie County, Perrnitting Maximum fuse 40A 40A 50A 60 A 60 A 70 A
Test
Performances
80F amb,80F 51,000 64,000 85,000 105,000 121,000 137,000
water,80%RH* BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr
COP 5.6 63 6.0 5,5 5.5 6
80F amb,80F 49,000 60,000 80,000 100,000 116,000 131,000
water,63%RH** BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr
COP 5.4 6.1 5,8 5,4 53 5.8
50F amb,80F 34,000 40,000 58,000 70,000 80,000 87,000
water,63%RH** BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr BTU/Hr
COP 1 4 4 4 4 4 4
Defrost
® Air Air Air Air Air Air
5 Hot gas Hot gas Hot gas Hot gas Hot gas Hot gas
Installation Instructions
Location
The placement of the pool heater is very important in keeping installation
costs to a minimum while providing for maximum efficiency of operation, as
well as allowing adequate access for service and maintenance.
The THERME4U pool heat pump is designed for outdoor installation and
should not be installed in a fully enclosed area,such as a shed, garage,etc.,
unless ventilation is provided to ensure adequate air exchange for proper
operation. Recirculation of cold discharged air back into the evaporator coil
will greatly reduce unit heating capacity and efficiency.
The unit should be located as close as practical to the existing pool pump and
filter to minimize water piping. However, do not forget to provide a 18" clear-
ance at the very least all around your heat pump.
Mount the unit on a sturdy base,preferably a concrete slab or a set of blocks.
The size of the base should not be less than 40"x 40" (100 cm x 100 cm).
A IMPORTANT
All THERMEAU pool heat pump models feature patented,ultrasilent ventilation
systems.Air is pulled through the evaporator coil and discharged through the
top grille.A minimum clearance of 48 inches should be allowed above the unit
for unrestricted air discharge.The unit must not be installed under a porch.Any
side of the unit should be located at least 24 inches from a wall or from any
other obstruction for unrestricted air intake and service access.
r
Fig. 1
T7 117t,
�:a•ri.wn _ j � � �
.. !�
�lE'MneSie
Fffi7dts IWl18m
OWNER'S MANUAL TEIERN�
IMPORTANT
AJ!T.';ERMEAv pool heat pump models feature ultrasilent ventilation systems.
Nr is pulled through the evaporator coil and discharged through the tot;grille.
A minimum clearance of 43 inches should be allowed above the unit for unre-
stiicted air discharge.The unit must not be installed under a porch. Any side
of the unit should be located at least 12 inches from a wall or from any other
obstruction for unrestricted air intake and service access.The back side of the
unit or one of the two sides peft or right) could be installed at 6 inches from
any obstruction as long as the two other sides are at a minimum of 12 inches
distance of any obstruction.
•r.�-twn '
- z
Prion. pmvu
dap r:a•
i !
48'Minimum
l
Minimum I
i V t
Front view
OWNER'S MANUAL
i
I
I
In compliance with the Florida Building Code 301.13,pool heat pumps
must be anchored to a structure for hurricane resistance.
Anchor are required on each installation.
Installation: Figure 1.Anchor Positions
1.Place the THERMPAU°Heat Pump Attach anchor brackets to base of heat pump
at ifs permanent location where indicated by the arrows.
on the equipment pad.
Installer to provide anchors bolts
and the suitable concrete anchor
to attach the angle steel bracket
to the equipment pad
2 Place the angle steel bracket at the
boltom of the THERMEAU'Heat Pump
as ndcated(fig.l)
&Boll on the angle steel bracket
to the base as indicated(Firg.2).
4.Mark the 9A1e
ion of the halt.
in each angle steel bracket
on the backing material
S.Drill a hole at each mark _
into the equipment pad. ]
6.Insert a bolt anchor in each hole
completely. a
7.Line up anchor the angle steel bracket
holes and bort anchors(Fig.2). Figure 2.Angle Steel Bracket
8 Put on anchor boU in each angle
steel bracket.
t
t�
EYAPORATORE
(REAR)_Z�j Q �b
MEN � � C-_ r� FES
CONCRETE
EQUIPMENT .-
HEAT PUMP \_ �� PADS /
ANCHOR BRACKET ` —-3"_minunum
EVAPORATOR
COIL GUARD
HEAT PUMP
PLASTIC
BASE
vb,%INE3-S NIANU,4L •..