HomeMy WebLinkAboutProduct Approval rlonud owwu.y ......c 1/01.0,y-14 AM
s f
Professional Reaulation
BaS Home l Log In t User RegMtratlon ? Hot Topics i Submit Sundwge 1 Stats h Facts Pubiimbons FBC Staff BM Site Map j Unks Search
act*=.
Approval
Ptaft User
RECEIVED
t Product Approval Menu>AWb ati m Debit (2017
FL# FL10674-R13 APR 0 3 2018
Application Type RevisionST. Lucie County, PermittinCode Version
Application Status Approved
Comments
Archived ILE COPY
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7829
g reg.keeler@owertscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomg_com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
�— Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI R13 COI 2017 01 COI Nieminen�f
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegiCQ8ucR6ixEBFhs7tuJgZew%3d%3d Page 1 of 2
Florida Building Code Online 1/8/18,9:14 AM
ASTM D7158 2011
Equivalence of Product Standards
Certified By-
Sections
ySections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model, Number or Name Description
10674.1 Owens Coming Asphatt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVH2: No FL10674 R13 11 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVH2:Yes SHINGLES FL10674-P13-ad€
impact Resistant: N/A Verified By: Robert 3. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other. Refer to ER, Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.odf
Created by Independent Third Party:Yes
t3adc Ptezt
Contact us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824
The State of Flonda is an AA/EEO employer:Copyright 2007-2013 State of Florida.::Privacy Statement::Acces ibil6.v 5tatP_rrnent::Rind State ne nt
under Florida law,email addresses are public records.If you do not want your e-mad address released in response to a pub6C-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by tractional mad.If you have any questions,please contact 850.487.1395. to Section
455.275(1),Florida Statutes,eftextrve October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Depar n with an email address if they have
one.The emads provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public-To deterinme if you are a licensee under Chapter 455,F.s.,
please dick ham-.
Product Approval Accepts:
® ® ® ® ®
https://www_floridabuilding_org/pripr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEBFhs7tvJgZew%3d%U Page 2 of 2
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authonzatron#9503
353 CHRISTIAN STREET,UNIT#13
oTRtWff
I:EKD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Coming Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6a' Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Coming Asphalt Roof Shingles
WlEuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPuANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERTtsEmENT: The Evaluation Report number preceded by the words -Trinity IERD Evaluated" may be displayed in
advertising literature. tf any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INsPEcnow Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by-
Robert J.M.Nieminen,P.E The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE2983
Nieminen,P.E on 10/0912017. This does not serve as an
electronically signed document.
CEATIRCATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity{ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Q0TRRN-fYIiERD
RomNG SysTEms EvAw4now
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Coming Asphaft Roof Shingles, as produced by Owens Coming, have demonstrated
compliance with the following sections of the 6"n Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.25,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CE R9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC OST9628) Wind Resistance 11CA34308 07/18/2012
UL LLC(TSr9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC CTST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(rST9628) Physical Properties Classification letter 02/13/2014
UL LLC{rST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, Tru Definition Duration, Duration Premium Cool, Tru Definition Duration Designer Color
Collection, Tru Definition Oakridge, Oakridge* and WeatherGuard* HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
43 Accessory Starter Strips:
43.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. UMITAnoNs:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.0212-R8
Co�ofAutlw=Wn#9503 6i'EDMON(2017)FBC NON-HVHZ EVALUATION FL1G674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TTRNTYIERD
s.4 Wind Classification:
5.4.1 All Owens Coming asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and 8905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to V,� = 150 mph (V,k = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Pius noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and 8905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to V,,d=150 mph(V„K=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underiayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3, per FSC 1507.23,1507.2.4 or R905.23.
6.2 Asphalt Shinales:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle.
➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle.
➢ DevonshireTM shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Fait mdubpurt Decf r,tAd. .� trs�
saf�sa �J a.+.t..r
adw
' •R'lmiTli.l1{i �y
edheeo
>:ramuned Plim Om oretmw cam aodaiwsV-i'i' 3unw rmavu*mp odMmUr-SW
Extenor Research and Design,LLC Evaluation Report 037940.02.12-R8
C&1 fxxd a ofAu&"=don#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision&10/09/2017
Page 3 of 8
TTRR#q[TYIERD
I
6.2.6 Minimum Nailing—Classic®&Supreme:
ttire>�1 ds�eia�as y
tttlt��uwr �� � y.7saa.r.t.s rA Nwtait
.iYw�a.itfiwtirsa�pw�iri
Ifxp-
i fifib'de'3e
6.2.7 Minimum Nailing—Berkshire®:
L'L'j I
Standard Fastening Pattern 6-Nail Fastening Pattern
Seol�its8i
is lFado aoY.lir
r••
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design.LLC-C Evaluation Report 03796042-12-R8
C,grbykmteoJAud"watioo89503 6'"EDfr1ON(2017)FUC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphatt Roof Shingies Revision 8.10/09/2017
Page 4 of 8
E{M�Q
T Ll W
6.2.8 . Minimum Nailing—Devonshirtm:
Iifals �T
c�.�ewa.aaa� IJ�ie�eiialMi�itlor W C�
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration•, TruDefinition® Duration, Duration• Premium Cool & TruDefinition
Duration Designer Color Collection:
4ilaflres gf4pnn sii[FobOisPsgaa
t :1r tr 11
Standard Fastening Pattern 6-Nail Fastening Pattern
��ir E1�Ma Ae+f�r7fili�t2i�
_ E
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC Evaluation Report O37940A2-124R8
of +e 6'EDMON(2017)FBC NON.HVHZ EVALUATION FE10674-R13
Owens Coming Asphalt Roof Shingks Revision 8:10/09/2017
Page 5 of a
TTP,NTY.lBkD
63 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Coming current published instructions,
using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the
Owens Coming current published instructions, using two (2) nails per shingle. Refer to Owens Coming
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire•Hip&Ridge and High Ridge:
p" c r
i
'-T• V. i
i
II
1
. . ...... .... ..
6.3.4 Minimum Nailing—WeatherGuard'HP Hip and Ridge:
Rg.& P 4t
A•
I I
Exterior Research and Design,LLC. EVWUV ion Report 03794042.12-RS
CartUftaft of ar -4 r 5 6'EDMONt(2027)FBC NOH-HYMZ EVALUA710N FL10674-R13
ow—GxnaW Asphak Roof SWrWles Revision&10/09/2017
Page 7 of 8
� TMITYIERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Stoodwd
11k Dbacti= 9tt•
int� Patera
F do
ago ON~
• tr
6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
T.p%m
OlP Iiabulim iaii�ai+�c +e AWMPW�r r
�iirs�oii.rs
21 o,.
"Ni
I
■
i M2
I , I i e• $
t r t I*
�It6c
u
r-�
I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2-7.1/R905.2-6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product-
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458; Kanchi_Agrawala-Dokania@ui.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC Evaluation Report 037940.0-12-R8
GffgkateofAu&"fzat n#9503 6'EDMON(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8