HomeMy WebLinkAboutProduct Approval so W. .
A.,
hum
,
ra ► � ,
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
b'
rProduct Approval
f USER:Public User RECEIVED
Product Aiq val Menu>Product or 60lica[ion Search>AA lica ion7rL5259-R27
lication tail
FL# MAR 2 8 2018
Application Type Revision $'(, 6yCiE County, Permitting
Code Version 2017 _.._
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport nter i
E CO P
Deerfield Beach, FL 33442
(954) 233-1378 Ext 242
alender@polyglass.com
Authorized Signature Ariel Lender
alender@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAIpert@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALender@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By John W. Knezevich,PE
I Validation Checklist-Hardcopy Received
Certificate of Independence FL525 R27 COI-2017 Q1QQI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D6164 2011
ASTM D6222 2011
FM 4474 2011
FRSA/TRI April 2012 2012
TAS 103 1995
TAS 110 2000
t UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/14/2017
Date Validated 09/15/2017
Date Pending FBC Approval 09/18/2017
Date Approved 12/12/2017
Date Revised 01/24/2018
Summary of Products
FL# Model,Number or Name Description
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL525 R27__II 2017_Q4_FINAL_ER_POLYGLASS_UNDERLAYMENTS_FL 2 -
Approved for use outside HVHZ:Yes R27. fQ if
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL525 R27 AE 2017 Q_9 FINAL ER POLYGLASS UNDERLAYMENTS FL 2 -
underlayment system(over concrete deck)for R27.pdf
use under foam-on tile systems(where the Created by Independent Third Party: Yes
underlayment forms part of the load-path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer,"mht 2007-2013 Stale of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
® ® ®Z-
Credit Card
Safe
1
r
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
QOTRINITY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R23
150 Lyon Drive FL5259-R27
Fernley, NV 98408 Date of Issuance:02/24/2009
(570)384-1230 Revision 23:09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6"' Edition (2017) Florida Building Code sections noted
herein.
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity(ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by: •�...��,.,�„,,,����,.
Robert J.M. Nieminen,P.E. - ��t`c e7 ND %T� The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 ±•,1%i.; '` P.E.on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
Entity Examination Reference Date
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NCA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced, surfaced
with polyolefinic film surface;meets TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an
m t
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and TAS 103.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 3 of 14
TRINITY ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polyglass APP Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
P stick MTS Yes Yes No Yes Yes Yes
Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes No No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Underlayments
Approval
DAP Foam Touch'n Seal Storm Bond Roof FL14506 Polystick TU Plus,Polystick TU Max
Tile Adhesive
Dow TileBond'" FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass Polyl-ok Roof Tile Adhesive FL17855 Polystick TU Plus or Polystick TU Max
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,I.L.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 5 of 14
TRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations), Dual Pro,Tile Pro,Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
ie New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
058 sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
'w ASTM D41 primed structural concrete.
5.6.2 Bond-to-insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self-adhered
to:
ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
:e ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
5- ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
r ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
io Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12),Appendix A, Table 1,or as listed in Section 5.6.4 herein,or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)354-1230 Revision 23:09/14/2017
Page 6 of 14
TRINITY ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSAJTRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Un_d_erlayment Tile Profile Staging Method Maximum Slope
Flat 10-tile stack 7:12
Elastoflex G TU
Lugged 8-tile stack(6 over 2) 6:12
Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Flat or Lugged Prohibited without battens N/A
Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat 6-tile stack(4 over 2) 6:12
Lugged 6-tile stack(4 over 2) 4:12
Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top-layer underlayment,as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Two
Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein,coupled with
FRSA/TRI April 2012(04-12)Installation Manual.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#950.3 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Undedayments;(570)384-1230 Revision 23:09/14/2017
Page 11 of 14
TRINITY ERD
6.4 Polystick MTS,IR-Xe,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or MU X or Pofyffex S'O"Pofyfiex SAP FR,}Vtufe-Hide
-APP A
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed
using the above noted fasteners and spacing, in area marked "nail area,area para clavar"on the face of membrane.
The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick Dual Pro,IR-Xe or Polystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on the systems over Polystick MTS,battens are required for loading/staging of the tile.
6.4.4 Two(2)Ply Underlayment Systems:
Polystick MTS followed by Polystick MTS,TU P,TU Plus,TU Max,Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material.
This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Undedayments;(570)384-1230 Revision 23:09/14/2017
Page 12 of 14