HomeMy WebLinkAboutProduct ApprovaldProduct Approval
Lid or
USER: Public User
Praduct Approval Menu > Product or Application Search > Application List > Application Detail
FL *
FL10674-R13
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel. sancrant@owenscorn ig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or
Professional Engineer
-. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard
ASTM D3161
YM
201
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
ASTM D3462 201
ASTM D7158 201
Method 1 Option D
10/10/2017
10/11/2017
10/15/2017
12/12/2017
FL # Model, Number or Name Description
x10674.1 — Owens Coming Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hiE
I Shingles and Starters
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Installation Instructions
FL10674 R13 II 2017 10 FINAL ER OC AE
SHINGLES FL10674-R13.odf
Verified By: Robert J. M. Nieminen PE - 5916,
Created by Independent Third Party: Yes
Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC A
SHINGLES F1_10674-1113.odf
Created by Independent Third Party: Yes
Contact Us :: 2601 $lair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: S
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request,
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pt
455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F,S, must provide the Department with an emal
one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. if you do not wi:
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee un
please click here .
Product Approval Accepts:
Cred+t Card
Safe
,t
T JNITY ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
EXTERIOR RESEARCH & DESIGN, U.C.
Certifi ote of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Evaluation Report 037940.02,12 -RS
FL10674-1113
Date of Issuance: 02/06/2012
Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. an 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERS
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6'h Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
IICA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER3592)
FRC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles
4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 Devonshire`" are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration, Tru Definition Duration, Duration Premium Cool, TruDefinition Duration Designer Calor
Collection, Tru Definition Oakridge, Oakridge and WeatherGuardr HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LiMiTATiONs:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report 037940.D2.12 -R8
CerfWate ofAuthurGaBon #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 8
r } >
<' TRINITY ERS
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Vast = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vox = 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
g2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire^" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt underlavment Ded
Sof adhered
Nbatlud.ock'
urAwleonant
— odp
t'
Nails bated
r-3' 6om eeee
install Fort - SaO-sedmg adhesive
stern✓ 9Bio poehimud along me
N wah
Starter strip shingle ove,harps eaves and rakes N5 V
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8
Certrylcare ofAuthorkatian X9503 6'" EDITION (2017) FBC NON-HVHz EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 3 of 8
6.2.6 Minimum Nailing — Classico&Supreme:
film , I� Am pore
reas Nigh 1�Nnd y
Awa pan vhwm* no"w" Areas vlsn htntea
r' a
it exnowto • �• I•
lrpesteldn
6.2.7 Minimum Nailing— Berkshire':
Standard Fastening Pattern
_} TRINITY ERD
Normal Mam," or Area pan
Wind Mae HIa1 Wind daswxes y.
AM Pare vionma mnrabs Arias vhstw"
r' fAl r � _• t x'
I
B MPexposur-
exia"A fda
Solw vbip
La 0a de W400,
• eN • fh • • 6,Y • a%"
r
r
6 -Nail Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certggcete ofAuthernet1w x9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 4 of 9
6.2.8 Minimum Nailing -Devonshire'":
uxW%eovn ae a era pug {dg del sellador
Standard 6 -Nail Fastening Pattern
TRINITY ERD
. _.�.., Naskl�7 .,..��.
r
F
1 Too Spon of Asphaft Root Cement
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration", TruDefinition" Duration, Duration" Premium Cool & TruDefinition
Duration Designer Color Collection:
ellen raxetning P t
Standard Fastening Pattern
em.x.me,rwas..
Mansard or Steep Slope Fastening Pattern
ee.xaae"rw."rm
6 -Nail Fastening Pattern
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8
Certffi to o7Authorrxotmn#9509 6r" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
6.2.1 Minimum Nailing — TruDeiinition Oakridge®,Oakridge":
4 Nag Paaatn
Fs40ana can d dAos
66/6" 6groaurt
apaaaa+eassrspw4.
Standard Fastening Pattern
FutwBnRfm
IW
TRINITY' ERC?
6 Nail Paturn
EtWuna cwt6claaos
r r
�-►I k-12'
66/e" FSpDNR!. fb 66/8" Fxpowe
�oaabrt de 6616pN0. Ftyoaa6r+M 85l8Pa0.
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuard® HP:
6 -Nail Fastening Pattern
0400 a& &law
Vbb gMnd
=l�i�e i.
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-Rg
f rt89rate of Authorhotlon#90a 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FI -1004-R13
Owens Coming Asphalt Roof Shingles Revision 9: 10/09/2017
Page 6 of e
E
TRINITY `i ERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge' Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire° Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing— WeatherGuard" HP Hip and Ridge:
Fig. A
propr 1r#q
t—pMb�n
WI!
A I j
Fig. C Hip & Ridge Shingle Faltering
T iopVYa
itMn6 Wb
7.
I
T. 1. —
l
g' EYp011ln: '.
I
Exterior Research and Oesign, LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorkation#'9503 6'"EDITION(20171 FBC NON-HVH2 EVALUATION 171.10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prorva"
vwind DirneBon subm 8trb
*ire M EaFeaw
--
'4
f TRINITY; ERD
6.3.6 Minimum Nailing—DuraRidge^' Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
�— N..a"gvNM Di.rte.a
D'n.mm dm:wMwda.�t
pnrem 40 vine pdanimxta
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R90S.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certykate of Authorization#9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 9