Loading...
HomeMy WebLinkAboutProduct ApprovaldProduct Approval Lid or USER: Public User Praduct Approval Menu > Product or Application Search > Application List > Application Detail FL * FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel. sancrant@owenscorn ig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or Professional Engineer -. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard ASTM D3161 YM 201 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ASTM D3462 201 ASTM D7158 201 Method 1 Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 FL # Model, Number or Name Description x10674.1 — Owens Coming Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hiE I Shingles and Starters Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Installation Instructions FL10674 R13 II 2017 10 FINAL ER OC AE SHINGLES FL10674-R13.odf Verified By: Robert J. M. Nieminen PE - 5916, Created by Independent Third Party: Yes Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC A SHINGLES F1_10674-1113.odf Created by Independent Third Party: Yes Contact Us :: 2601 $lair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: S Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pt 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F,S, must provide the Department with an emal one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. if you do not wi: address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee un please click here . Product Approval Accepts: Cred+t Card Safe ,t T JNITY ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 EXTERIOR RESEARCH & DESIGN, U.C. Certifi ote of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 037940.02,12 -RS FL10674-1113 Date of Issuance: 02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. an 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERS ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6'h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance IICA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER3592) FRC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles 4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. 4.1.3 Devonshire`" are fiberglass reinforced, 5 -tab asphalt roof shingles. 4.1.4 Duration, Tru Definition Duration, Duration Premium Cool, TruDefinition Duration Designer Calor Collection, Tru Definition Oakridge, Oakridge and WeatherGuardr HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LiMiTATiONs: 5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 037940.D2.12 -R8 CerfWate ofAuthurGaBon #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 2 of 8 r } > <' TRINITY ERS 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vast = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vox = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. g2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. ➢ Devonshire^" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Felt underlavment Ded Sof adhered Nbatlud.ock' urAwleonant — odp t' Nails bated r-3' 6om eeee install Fort - SaO-sedmg adhesive stern✓ 9Bio poehimud along me N wah Starter strip shingle ove,harps eaves and rakes N5 V Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certrylcare ofAuthorkatian X9503 6'" EDITION (2017) FBC NON-HVHz EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing — Classico&Supreme: film , I� Am pore reas Nigh 1�Nnd y Awa pan vhwm* no"w" Areas vlsn htntea r' a it exnowto • �• I• lrpesteldn 6.2.7 Minimum Nailing— Berkshire': Standard Fastening Pattern _} TRINITY ERD Normal Mam," or Area pan Wind Mae HIa1 Wind daswxes y. AM Pare vionma mnrabs Arias vhstw" r' fAl r � _• t x' I B MPexposur- exia"A fda Solw vbip La 0a de W400, • eN • fh • • 6,Y • a%" r r 6 -Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certggcete ofAuthernet1w x9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 4 of 9 6.2.8 Minimum Nailing -Devonshire'": uxW%eovn ae a era pug {dg del sellador Standard 6 -Nail Fastening Pattern TRINITY ERD . _.�.., Naskl�7 .,..��. r F 1 Too Spon of Asphaft Root Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration", TruDefinition" Duration, Duration" Premium Cool & TruDefinition Duration Designer Color Collection: ellen raxetning P t Standard Fastening Pattern em.x.me,rwas.. Mansard or Steep Slope Fastening Pattern ee.xaae"rw."rm 6 -Nail Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certffi to o7Authorrxotmn#9509 6r" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 6.2.1 Minimum Nailing — TruDeiinition Oakridge®,Oakridge": 4 Nag Paaatn Fs40ana can d dAos 66/6" 6groaurt apaaaa+eassrspw4. Standard Fastening Pattern FutwBnRfm IW TRINITY' ERC? 6 Nail Paturn EtWuna cwt6claaos r r �-►I k-12' 66/e" FSpDNR!. fb 66/8" Fxpowe �oaabrt de 6616pN0. Ftyoaa6r+M 85l8Pa0. Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard® HP: 6 -Nail Fastening Pattern 0400 a& &law Vbb gMnd =l�i�e i. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-Rg f rt89rate of Authorhotlon#90a 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FI -1004-R13 Owens Coming Asphalt Roof Shingles Revision 9: 10/09/2017 Page 6 of e E TRINITY `i ERD 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge' Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire° Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing— WeatherGuard" HP Hip and Ridge: Fig. A propr 1r#q t—pMb�n WI! A I j Fig. C Hip & Ridge Shingle Faltering T iopVYa itMn6 Wb 7. I T. 1. — l g' EYp011ln: '. I Exterior Research and Oesign, LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorkation#'9503 6'"EDITION(20171 FBC NON-HVH2 EVALUATION 171.10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prorva" vwind DirneBon subm 8trb *ire M EaFeaw -- '4 f TRINITY; ERD 6.3.6 Minimum Nailing—DuraRidge^' Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. �— N..a"gvNM Di.rte.a D'n.mm dm:wMwda.�t pnrem 40 vine pdanimxta 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R90S.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certykate of Authorization#9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 9