HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online 1/8118,9:14 AM
i
i
i
s ! Professional +
tion
Horne I
BdS Ho
e ! Log In User Registration ! Hot Topics j Submit Surcharge 1 Stats&Fads Publications ; FBC Staff BCLS Site Map i Unks ; Search
orProduct Approval
Public User
r'�.Yf+TI 61yi@G
Prod=Approval Menu>Application Detail
FL,# FL10674-R13
:Application Type Revision
i Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
i
•+i Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.odf
Referenced Standard and Yearof Standard)) Standard Year
ASTM D3161 2016
ASTM D3462 2010
i
https//.ww.florid.b.ilding..,g/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQSucR6ixEBFhs7tvJgZew%3d%3d Page 1 of 2
I
Florida Building Codc.Online 1/8/18,9:14 AM
ASTM D7158 2011
Equivalence of Product Standards
Certified By
i
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
I
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FI 106,74 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant N/A Verified By: Robert J. M.Nieminen PE-59166
Design Pressure:N/A 'Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.pdf
Created by Independent Third Party:Yes
Back Next
I
Contact-Us::2601 Blair Stone Road Tallahassee Fl.32399 Phone:8S -487-1824
I
The State of Florida is an WEED employer.r'oovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a pubOc-records request,do not send elecumic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant m Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they,have
one.The emails provided may be used for official communication with the ikensee.However email addresses are public record.If you do not wish be supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please dldc hie.
Product Approval Accepts:
I
i
https.//www.floridabuilding.org/pr/pr-app_dti-aspx?param=wGEVXQwtDgtBNbEYSV%2boQT%2b6w7ahRegiCQSucR6ixEBFhs7tvJgZew%3d%3d Page 2 of 2
I
I
I
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authortzaton#9503
353 CHRISTIAN STREET,UNIT#13
iR : I'.':1.•. :
RD OXFORD,CT 06478
Q. R- (203)262-9245
EVALUATION REPORT
Owens Coming Evaluation Report 037940.02.12-RS
One Owens Coming Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
jconstruction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6v' Edition (2017) Florida Building Code
sections noted herein.
Dii SMPTION: Owens Coming Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and OBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: ����.SF.=ma.,,,�
A�s a.?d.::r
y
- rt�ip' S„may ;t
Robert LK Nieminen,P.E. y,@ 4�`+��,y The facsimile seal appearing was authorized by Robert
Florida Fegistradon No.59166,Florida DC4 ANE1983 �'"���.n" Nleminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document
CER IFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
- T
YIERD
ROOFING SySams EvALuAnON*.
IL. SCOPE:
Product Category. Roofing
Sub-Category. Asphalt Shingles
Compliance Statement: Owens Coming Asphalt Roof Shingles,as produced by Owens Coming,have demonstrated
compliance with the following sections of the 6h Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016.
1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
EndW Examination Reference Date
UL LLC(CER9'626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wlind Resistance 20120516-82453 05/16/2012
UL LLC(TSI79628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02118/2012
UL LLC(M9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TSM628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter .02/13/2014
UL LLC M9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT MscmpTiom
4.1 � Asphalt Shinales:
4.1.1 Classic and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles.
4-1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.13 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duratibn*, TruDefinition Duration*, Duration Premium Cool, TruDefinition* Duration* Designer Color
Collection, TruDeflnition*Oakridge, Ciakridge*and WeatherGuardo HP are fiberglass-reinforced, laminated
asphalt roof shingles.
4.2 Hto&Rldne Shinitles
4.2.1 Berkshire Hip& Ridge Shingles, High Ridge, WeatherGuard HP Hip& Ridge Shingles, ProEdge Hip& Ridge
Shingles and Duralkidger"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
43 Accessory Starter Strips
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LimiTATioNs: -
5.1, This is a building code evaluation. Neither TrinitylERD nor Robert Nierninen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RSEDITIONN(2017)FBC Now"vi4z EVALUATION FL10674-R33
Owens Coming Asphalt Roof Shingles Revision Jk-10/09/2017
Page 2 of 8
QTR H- TYIERD
SA Wind Classification:
5.4.1 All-Owens Coming asphalt shingles noted herein are Classified in accordance With FBC Tables 1507.2.7.1*
and 8905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all Wind zones up to V,,d = 150 mph (V„rt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5-4-2 All Owens Coming hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Oassified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the
shingles are acceptable for use in all wind zones up to Vad=150 mph(VIt=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Coming published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 6IG20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Undedayment shall be acceptable to Owens Coming and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2A or R905.2.3.
6.2 Asphalt Shiniz4es:
6.2.1 installation of asphalt shingles shall comply With the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R90S.2.6, with the following
exceptions:
> Berkshire'shingles require minimum five(5)nails per shingle.
> WeatherGuarde HP shingles require minimum six(6)nails per shingle.
> Devonshire'"shingles require minimum six(6)nails per shingle.
>
Starter* Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip_
Refer to Owens Coming published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.LS. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
SdkK&W@d
wJrJ
GOP
�tiagista am
lar
OWN naso �raandx✓�esN4'-gyp
Exterior Research and Design,LLC. Evaluation Report 037M.02.12-RB
Certykate ofAud-rattan#9-So EDMON(2017)FOC NON-HVHZ EVAWATION FL/067
Owens Coming Asphalt Roof shingles Revision&10/09/2017
Page 3 of 8
TRTY I: .
6.2.6 Minimum Nailing—Classic®&Supreme:
.�lierif:
aa;llii�i9'ias�iort ;> +tlea ;rsrivaoon�TMs rai +rebs
yr
6.2.7 Minimum Nailing—Berkshire*:
1 lstbdlaae�aor
- .iY:.:..:a i3's �-'r Wit---- ri ••---►��-----•• •.---r��i•
8W 8w 8 TW
IJ
Standard Fastening Pattern 6-Nail Fastening Pattern
i
I
lam
I 2•• ..'' Yrr .: ..
I
Mansard or Steep Slope Fastening Pattern
i
I
Exterior Research and Design,LLC Evaluation Report o37940A2.12-R8
Cabfimoe ojA d-rit tion 19503 61"EDITION(2017)FBG NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
TRNTYIERD
6.2.8 Minimum Nailing—Devonshir6-:
Q0Q
I '
Swap=
= Salt�li>e �. T
6�01idd11de8�dpt�g li�indd>Iddrrta�dar �,
i
Ten P di'1vb*ftd£
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing - Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
nr rs ,r
I .
Standard Fastening Pattern 6-Nail Fastening Pattern
Fsb�forslop!es�iiegOY"i�ao29�•.
�+M+■8.4.. m
iiia
owl
Mansard or Steep Slope Fastening Pattern
I
I '
I
I
Exterior Research and Design,LLC. Evaluation Report 037940.02-32-Ra
CeaftoteofAud—t don#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10574-R13
Owens Corning Asphalt Roof Shingles Revision&10/09/2017
Page 5 of 8
j
1
I '
\\JTRNTYJ-
6.3 Hip&Ridge Shingles:
6.3.1' Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge m Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R90S.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
1:; .. sais r waus
r r �
� I.
1
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
I
A'
i
�•.: is
Ti S
I
I
i
I
Exterior Research and Design,LLC. Evaluation Report 037940.02.1Z-118
Qrb ieaW ofArrtho&UMn#9503 6"'EDMON(2017)Fsc NOW-HVHZ EVALuA-noN FL11674R13
Owens Coming Asphalt Roof Shingles Revision&10/09/2017
Page 7 of 8
TTR�JEW
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevalrbe fid" ��•
Ir 10, �� t-1 t►��T
cow
6.3.6 Minimum Nailing—DuraRidge u Hip&Ridge Shingles:
j Note:The drawings below pertain to minimum,as tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
~ vh-= r
Cb
� ow.
t
it �r rfill
Clog
I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications.detailed in FISC
Table 1507.2.7.1/R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
i
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
I
Exterior Research and Design,LLC Evaluation
Report
Ceb"f-to cfAud—&utbn 4WW 6r"EDITION(2017)FRC NON-HVHZ EVALUATION . FL10674.R33
Owens Coming Asphalt Roof Shingles Revision&10/09/2017
Page 8 of 8
i