Loading...
HomeMy WebLinkAboutProduct Approval 1 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 ' QOTRINITYIERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,Cr 06478 (203)262-9245 EVALUATION REPORT Soprema,_Inc. Evaluation Report S18010.06.09-1111 1640.rue,Haggerty FL2569-1113 Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 11:10/06/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, ' P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume.• The products!described.herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted herein. i DESCRIPTION: Soprema Roof Underlayments LABELING:, Labeling shall be in accordance with the.requirements the.Accredited.Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time-as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code thatTelate to the product change. Acceptance of { this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a-complete review of this Evaluation Report relative to updated Code requirements with.each Code,Cycle. t i ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,-then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at-the request of the.Bu.ilding Official. This Evaluation Report consists of pages 1 through 8. Prepared by:. Robert J.M.Nieminen;P.E. ;o• �p?�'�=' The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983i•1�i �� E;�kl: Nieminen,P.E.on 10/06/2017.This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: ' 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. j 3. Robert Nieminen,P.E.,does not have nor will acquire,a financial interest in any company manufacturing or distributing products for whichithe evaluation reports.are being issued. 1 4. 'Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema; have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in,accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Enti Examination Reference Date i ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 I ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance - 2779.11.05-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10=R1 09/09/2010" ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM 01970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878). Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: i • 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in-two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a•self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. Exterior Research and Design,I.I.C. Evaluation Report 518010:06.09-1111 Certificate of Authorization 89503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 2 of 8 no TRINITY E ERD 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified-bitumen, roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature,.SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 Lastobond 195 is a'self-adhering, glass-mat reinforced, sand-surfaced,.SBS modified bitumen roof underlayment;meets ASTM D1970. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced,film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 1 RESISTO L81236 i a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof n erlayment,with a 36-inch sheet width;meets ASTM D1970. 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.13 RESISTO LB1244 is a self-adhering, glass-mat.reinforced, sand-surfaced,. SBS modified bitumen roof underlayment,with a 44-inch sheet width;meets ASTM D1970. 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(0442). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert.Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. ! 5.5 Allowable Roof Covers: (`�� '�, �• �`,s^r.,;, z."�'� ,„w � rs-� ti�� c , ,TABLE�. ROdf COVER OPTIONS � <-�� i Iz �'"�.��,,.� r �yR zf5 ��.t �„ ��t r Asphalt Nail-On Foam-On Wood Shakes& Underlayment Shingles Tile Tile Metal Shingles Slate ,t SSI L 1 I a e 41 ":Ye54 X fN' G I T '-,-i r= t r Lastobond TU HT ?r Yes } 1 Yesr t P Pit f, 4 ` ,r y, k 4 Yes Yes:t rr[.,* =YeS.„ 3�*See Lastobond ShieldN RESISTO SA HT -N +ro - u+4i i r" i�&mk »{ tVk i / / ,Iry C {�i ,� , .t,o «,+�R (1�p Yes SMOOTH PLY 40 x ”, p ��fY Fru �, 5 rV y Lastobond Shield HT/Pro HT-S KIM", ;tii N�i�1 ads �„ Yes r Yds„7 � , Yes"�,n Lastobond Eaves Protection Sheet/ w 4 p t �! 9CrF. '9 fh a7 r1 F -✓' Lastobond 195 Yes f atm,IVo�r,;e ^� f No `{( Yes, Yes . Ski tY,,.� N! 1'4161 Lastobond ECO RESISTO L61236,Grip- ...... n ' ,1. tz r tl li. Rite Eave&Valley Protector/RESISTO Ye54 ��'� �,iVo' s � �pprt,,(�q;i'�y, � ItNor C rYeA�r 3 Yes, f LB1244 Exterior Research and Design,LLC Evaluation Report S18010.06.09-1111 certificate of Authorization A9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 3 of 8 s a - QO {' TRINITY ERD 'j "-c°�'+'`,� t�,� �`r i X, s ss����' �� �{�"'r s� � as i.. ,�::d w`_.v�. �..;�.� «,'s .�;...f 6s psi r �•£r.s'.:: p.�tr�,r fir: s, v1 Asphalt Nail-On Foam-On MetalWood Shakes& Underlayment Shingles Tile Tile . Shingles Slate Lastobond Smooth Seal HT ;. ' ,'YeS r Colphene FR GR 5:5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives./underlayment combinations. �'t"Tc r yt y�j r K F,.. S h 3 s• _ a. •� ry..{ > �� ABLEIA /4LLOWABLTILEADFIES'IVE UNDERLAYMENTCOMBINATION5 I. ... 4.Sx"S`7 •....,s:r .s h vrr. 'h., Adhesive Florida Product Approval Underlayments Dow TileBond'" FL22525 Lastobond TU HT ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: i 5.6.1 Direct-Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT-applied to:" Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. i i 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations undee foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,Testing Application Standard TAS 114,Appendix J or UL1807. i - I I Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning.Moment Resistance Performance. Exterior Research and Design,U.C. Evaluation Report S18010.06.09-RSI certificate of Authorization 119503 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 4 of 8 ��TRINITYJERD 5-6.3 Bond to Mechanically Attached Base Laver: I Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro l HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, jand reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609.for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority. Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #2 Maximum Design Pressure=-67.5 Dsf: i Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #3 Maximum Design Pressure=-150.0 Dsf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/Sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids,and ensure there are no voids/bridging at i side and end-laps. i #4 Maximum Design Pressure==60.0 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on file systems carry a Maximum Design Pressure of-45 psf. Exterior Research and Design,U.C. Evaluation Report S18010.06.09-R11 Certificate of Authorization J79503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL2569-1113 Soprema,Inc. Revision 11:10/06/2017- Page 5 of 8 TRINITY ERD 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data.Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB3236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30- days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA.SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck the assemblies,the maximum roof slope shall . be as.follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. '? s �s a „ T „LIPPAGE LIMITATIONS FOR DIRECr,DECI�TIiE INSTALI ATIONS `.cri,3Ol ? -a,4= '��c;,j TABLE 2 s. ILE$ Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack i shall be inverted,followed by 8 tiles high 6:12 on slope as shown below) j Lastobond TU HT Lugged v � y Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 Exterior Research and Design,U.C. Evaluation Report 518010.06.09-Ril Certffcrite of Aethorization#5503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1113 Soprema,Inc Revision 11:10/06/2017 Page 6 of 8 TRINITY ERD 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER(if applicable). 6 3 y y Lastobond TU HT,Lastobond Shield;Lastoliond Pro Hj N,RES)STO SA SMOOTH PLTY'AU,Lastobond shield'= Fiy ` }HT;� asto and Pro HT S;.Lastobond Eaves Protection Sheet, LasiobondU95z1astobond`Eco,£Lastobond: oaf Smooth Seal. L8 HT,RESlSTO 1236,Grlp RIte.Eave&a,Valley protector;RESI5T0 LB1244 or Colphene FR GR u �. z. .... �.r _- 1 6.3.1 Shall be installed in compliance with the 'requirements for ASTM D1970 underlayment in FBC Table I 1507.1.1 for the type of prepared roof covering to be installed. " 6.3.2 Non-Tile Applications: Whilepriming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover•is not slated for installation.within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the-substrate and unroll the remaining membrane.as far as possible. iOnce the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps 1 shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes'above 8:12,Soprema recommends back-nailing in the overlap area at the topof the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond•TU HT or Colghene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein,using the instructions noted above as a guideline. For foam-on tileapplications,reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or, damage to the I underlayment. See Table 2 herein,and Soprema published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: , As required by the Building Official or Authority Having Jurisdiction In order to properly evaluate the installation of this product. i Exterior Research and Design,LLC. Evaluation Report 538010.06.09-1131 CerQ7..to ofAoth.r1=W..#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION V FL2569-1133 Soprema,Inc. Revision 11:10/06/2017 Page 7 of 8 .i TOR INrryj ERD 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61(320-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. PlahV2 Specification 4c {':.Y PrOdUCt S Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,Lastobond.195,Lastobond QC(Canada) ASTM D1970 Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT, RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector, RESISTO LB1244. ASTM D1970&FRSA/TRI 04-12 Colphene FR GR . Wadsworth,OH Lastobond 195,Lastobond Eaves Protection.Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236;PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR Gulfport,MS Lastobond 195;Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley.Protector,RESISTO LB1244 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancelior@us.ul.coin -END OF EVALUATION REPORT- } I ji 1( .III f f I 1 ' Exterior Research and Design,U.C. Evaluation Report 518010.06.09-R11 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 8 of 8 EXTERIOR RESEARCH&DESIGN,I.I.C. -Certificate of Authorization#9503 �^�w '��! ERD 353 CHRISTIAN STREET,UNIT#13 r( 'V ((ER OXFORD,CT 06478 (203)262-9245- EVALUATION REPORT Soprema,Inc. Evaluation Report S18010.06.09-1111 1640 rue Haggerty `2569-R 3 i Drummondville,Quebec J2C 5138 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 11:10/06/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation'submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida'Building Code, Residential Volume. The productsdescribed herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the.requirements the Accredited.Quality Assurance Agency noted herein. . CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance.of i this Evaluation Report by the named client constitutes agreement to-notify Robert Nieminen, P.E. if the product changes or- the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:-The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ��))~tirgrnrry��� B. Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ,:�€ Nieminen,P.E.on 10/06/2017.This does not serve as in 1aiy� it�t�" electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a'financial interest in any company manufacturing or distributing products,it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not"have nor will acquire,.a financial interest in any company manufacturing or distributing products for which'the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor•Robert Nieminen, P.E. are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. r , TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCopp Product Category: Roofing i Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6"' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth I herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 '05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 I ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 I ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396)' 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 J Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). i 4.2 Lastobond Shield ,is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof I underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. Exterior Research and Design,U.C. Evaluation Report S18010.06.09-1111 i Certificate of Authorhadon#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1133 Soprema,Inc. Revision 11:10/06/2017 Page 2 of 8 TRINITY I ERD 4.5 Lastobond Pro. HT-N is a self-adhering, woven polyethylene surfaced,- SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro-HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Smooth Seal HT is a self.-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment.meets ASTM D1970. 1 RE�erlayment, a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof na 36-inch sheet width;meets ASTM D1970. 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adherin&glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.13 RESISTO LB1244 is a self-adhering, glass-mat.reinforced, sand-surfaced,. SBS modified bitumen roof underlayment,with a 44-inch sheet width;meets ASTM D1970. 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). j S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5:3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: 4'sr'r�`✓� �S '"�' ¢ ,rj� `� s�, al 1 i^ #P s' 3 :� s2 ', :. �' 5^-���. Sa. t ,< 3 �. BLE 3V I.a a sTAI OF COVER Underla ment Asphalt Nail-On Foam Metal-On Wood Shakes& y Shingles Tile Tile Shingles Slate Lastobond TU HTT Lastobond Shield gig",eFi,. l2 t F" j�; p t a„F.� •, - f /Pro HT-N/RESISTO SA a , „ SMOOTH PLY 40 / Y,�,� !}1`N�4 NB• !�3��t�.F�..N(yYld`!SV,"yt ) „Yes ' La ?.-:# Yes%i stobond Shield HTPro HT-5 Yes p Lastobond Eaves Protection Sheet/ LISFa as tz air"4� }f1�,�, Yes Ox ,45P' N �rfl�d E AFF i 3; Naf101 FH ; Ye5 Lastobond 195 Lastobond ECO /RESISTO L61236,Grip- Rite Eave&Valley"Protector/RESISTO r Ye5' '�'��o' �`�i''�EF�s�'�+ ,i 55 � '�'"�' �1 '' `"'" r �` ' Y i Y 4'r�rs�. 'vIVd�4'`1# h.f .�Yes4�,�, ,� F �::I YeS'Y{, L61244 rf !, err � a entiHt , ,a i Exterior Research and Design,U.C. Evaluation Report 518010.06.09-R11 Certificate ofAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc Revision 11:10/06/2017 Page 3 of 8 QOTRINITYI ERD �z ,. tn� y^° �a Y y�7 -' r`ice. h- s s - f .. ,,. � ',�i`amu.y„f. xi3'N.,,•,,:;.3 .anw7 o-'-�.:. F d f r i 7 +r xi r 7 �k=`�t^��i., �s�.,�.:�'..��.,TABLE Z.,.�OOF OVER,OPTIONs,.�`.'..>��-';_.��jo':•.'�,^.��''x_' s. >a���s;�d�'�-*'y-E{ ,f'c, Underla ment Asphalt Nail-On Foam-On Metal Wood Shakes& Y y Shingles Tile Tile Shingles Slate Lastobond Smooth Seal HT ;.„_1'eS �r Ndf �v 170, „ t� 1'es� Yes 4' Colphene FR GR Col P Yesiti F Yes i,w t v, ,hAI y } �'t�h f �ra icy Yp, t�F 4 eS � �t•I , Ye54 4.,-.�..v,'. _.,.,I!!•, �r .,...... .. a,,.,...ee55,1..r u.'�t,;..«mr4s.�x'�u .:,{ tr u..�d.s..k f� k: ti .. E r::7 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. � x�yk y F ,TABLE]A`ALLOWABLE TILE ADHESIVE UNDERLAYMENT,COMBINA_ Adhesive Florida Product Approval Underlayments Dow TileBond' FL22525 Lastobond TU HT ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: i Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:* - - ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. ( Colphene FR GR applied to:. ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed-by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix.D,Testing Application Standard TAS 114,Appendix J or UL1807. i z Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida ProduetApprovol for Overturning Moment Resistance Performance. Exterior Research and Design,U.C. Evaluation Report S18010.06.09-R11 Certificate of Authorization#9503 6T"EDITION(2017)FBC'NON-HVHZ EVALUATION FL2S69-R13 Soprema,Inc Revision 11:10/06/2017 Page 4 of 8 .I TRINITY`ERD 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR i applied to: ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). r 5.6.4 Wind'Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all un'derlayment'systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind ipressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority. Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,'self-adhered. #2 Maximum Design Pressure=-67.5 pSf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 1 #3 Maximum.Design Pressure=-150.0 psf: r I Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project -requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp I splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids,and ensure there are no voids/bridging at side and end-laps. 44 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. ' Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered I 5'.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of 45 psf. 1 I Exterior Research and Design,U.C. Evaluation Report 538010.06.09-R11 Certificate ofAathorizadon#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1133 Soprema,Inc Revision 11:10/06/2017 ! Page 5 of 9 y TRINITY I ERD 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. j Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 { design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in j Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: ' Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30- days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. i 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12))• When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. `3,°ec,r^"�;,, �� �"�yi ��,��TABLE2 ,TILE SLIPPAGE LIMITATIONS FOR DIRECL I7EC1(TILE lNSTA�LATIONS�:���' '` ` �'' r:L4 � ��r' •� r Underlayment n Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,-followed by 8 tiles high 6:12 on slope,as shown below) Lastobond TU HT Lugged �y Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 Exterior Research and Design,U.C. Evaluation Report 518010.06.09-R11' Ceroifrcate ofAutharization 119503 6T"EDITION(2017)FOC NON-HVHZ EVALUATION FL2569-1113 Soprema,Inc Revision 11:10/06/2017 Page 6 of 8 QOTRINITYIERD 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol 600cbr RESISTO EXTERIOR PRIMER(if applicable). 6 3�����f�lastobond TU`HT,Lastobond Shield,Lasto�iond Pro H�' IV;RESISTO 3A SM007HIPLYr40'(.astobond 5hleld; �- )at+. . i !�s Y( z` xr� -. �'"�'f-Y�' ¢n ♦ �2)� :, �r r i ,SS a t - � --}}�t BHT,:Lastobond Pro HTS, Lastobond Eaves-Qrotecfion Sheet Lastobond 195° Lastobond-.Eco Lastobond= �.�_ ;?�;:�Smooth Seal'HT,RESISTO LB1236,G�Ip RIte;Eave&.Valley,Protecto"r,RESISTO L61244 orfColphene FR GR i I Y.� 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. ? Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the.substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to.-shed water. Vertical seams should be 6- inches and staggered-not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch D.C. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein,and Soprema published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. I ' a i Exterior Research and Design,U.C. Evaluation Report 518010.06.09-RS3 Certificate ofAuthorizotion 119503 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R33 Soprema,Inc. Revision 11:10/06/2017 Page 7 of 8