Loading...
HomeMy WebLinkAboutBuilding Permit Application (2) • • it . m DESIGN SCHEDULE: 1"x4" MULLION WITH 'GOAL-POST' CLIP 0 MULLION TRIBUTARY WIDTH SPAN 18" 21" 24" 27" 30" 33" 38" 39" 42" 45" 48" I 53" v 106" 48.8 41.6 36.4 32.4 29.2 28.5 24.3 22.4 20.8 19.4 18.2 I 16.5 u 100" 51.5 44.1 38.6 34.3 30.9 28.1 25.8 23.8 22.1 20.6 19.3 17.6 w 6 88' 63.7....`46.0 40.2 35.8 32.2 28.3 28.8 24.8 23.0 21.5_ 20.1 18.2 0 90" 672 49.1 42.8 382 34.3 31.2 28,6 28.4 24.6 22.9 21.6 19.4 DESIGN SCHEDULE NOTES: cc ii 86" 59.9 51.3 44.9 39.9 35.9 32.7 29.9 27.6 26,7 24.0 22.6 20.3 D 84" 61.3 52.5 46.0 40.9 38.8 33.4 30.7 283 28.3 24.5 23,0 20.8 1. DESIGN SCHEDULES PROVIDE MAXIMUM ALLOWABLE -""''--" I '-"""""`-"---' POSITIVE(+)AND NEGATIVE(-)DESIGN PRESSURES FOR BQ 64.4 552 46.3 42.9 36.8 36.1 32.2 29.7 27.6 26.8 24.1 21.9 USE WITH MULLION SYSTEM IN POUNDS PER SQUARE 78" 66.0 56.6 49.5 44.0 393 36.0 33.0 30.5 28.3 28.4 24.8 22.4 FOOT(PSF). 76" 87.8 58.1 50.8 45.2 40.7 37.0 33.9 31.3 29.0 27.1 25.4 23,0 m 72" 71.6 81.3 63.7 47.7 42,8 39;0 35.8 33,0 30.7 26.6 28,6 24.3 2. FOR DETERMINATION OF MULLION SPANS AND TRIBUTARY WIDTHS,SEE ELEVATIONS ON SHEET 2. N o ''. 68" 75,0 86.9 56.6 62.0 46.8 42,6 39.0 36.0 33.4 31.2 29.3 1 28.6 I N $ o �....._...._.............._. w 60" 76.0 73,6 64A 572 51.5 48.8 42.9 39.6 38.8 34.3 32.2 I 29.2 3. FOR INSTALLATIONS UTILIZING MORE THAN ONE TYPE u-' 6 __6.._...._._.....__._.- _.._....._y__ 47.........-- OF CLIP PER MULLION,USE THE LESSER ALLOWABLE -N 64" 776.0 76.0 71.5 83,6 57.2 52.0 47.7 44,0 40.9 38.2 35.6 32A 2 w w i w _-----••••-• ------- DESIGN PRESSURE. ren m w ' 50.6" , 76.0 76.0 76.0 67.9 81.1 55.5 50.9 47.0 43.6 40.7 38.2 34.6 T- 48" 75.0 75.0 76.0 71.5 84.4 58.5 63.7 49.5 46.0 42.9 40.2 38.4 4. 'GOAL-POST'CLIP MAY NOT BE USED FOR CC o '--e INSTALLATIONS TO CONCRETE OR CONCRETE BLOCK 42" 75.0 76,0 75.0 76.0 73.8 66.9 613 66.8 62.6 49.1 48.0 41,6 (CMU). w rn o o w 38.4" 75.0 75.0 75.0 75.0 75.0 73.2 67.1 61.9 67.5 53.7 60.3 46,6 ci 5 j 3 ..g o 1 '-'116;11 76.0 76,0 75.0 75.0 76.0 76.0 71.5 86.0 61.3 57.2 63,7 48.6 5. ®DENOTES CONDITIONS NOT ACCEPTABLE Z o y D Q co¢MZ 30" 76.0 76.0 76.0 75.0 76.0 i 75.0 76.0 75.0 73.6 68.7 64,4 66,3 FOR USE. W�-' m 0 a 0 24" 75.0 75.0 76.0 76.0 75.0 75.0 76.0- 75.0 75.0 76,0 75.0 72.9 o a2,x P j a." - UlY,- DZ 4 Ei. 5 F-¢a a2 1 r r r g a o fi. DESIGN SCHEDULE: .1"x4" MULLION WITH T-CLIP OR 'C-CLIP CLD r S.2 k ,,,.p MULLION TRIBUTARYWIDTH 0 .a n SPAN 18" 21" 24" 27" 30" 33" 36" 39" 42" 45" 48" 63" z a 106" 59.0 50.6 . 44.2 39.3 35.4 , 32.2 29.5 27.2 26.3 23.6 22:1 20.0 * 2"Al 100" 70.2 60.2 62.7 46.8 42.1 38.3 35.1 32.4 30.1 28.1 26.3 23.9 8 ES 1e 98" 75.0 68.0 59.5 52.9 47.6 43.3 39.7 ' 36.6 34.0 31.8 29.8 27.0 90" 75.0 75.0 72.3 64,2 57.8 62.6 48.2 44.5 41.3 38.6 36,1 I 32.7 86" 75.0 , 76.0 75.0 73.6 66.3 60.2 55.2 51.0 47.3 44.2 ' 41.4 I 373 84" 76.0 75.0 75.0 75.0 _71.1 , 64,8 59.3 54.7 50.8 47.4 44.4 40,2 80" 75.0 75.0 . 75.0 75.0 75.0 74.8 68,6 63.3 58,8 54.9 51.4 46.8 78" 76.0 76.0 75.0 75,0 75.0 76.0 73.7 68.0 83.2 59.0 65.3 5071 76" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 71.9 68.7 62.3 68,4 52.9 72" 75.0 75.0 75,0 753 75.0 75.0 75.0 75.0 74.569.6 65.2 59.1 Robed J.Amoroso.P.E. 68" 76,0 75.0 75.0 76.0 75.0 75.0 75.0 75.0 75,0 75.0 71.2 64.4 Florida P.E.No.49752 60" 75,0 75.0 760 75.0 763 75.0 75,0 • 750 75,0 75.0 75.0 70.9 9` llnele. 54" 75.0 76.0 75.0 75.0 75.0 76.0 75.0 75.0 75.0 76.0 76.0 76.0 ‹r‘"•' gmEs °of 50,6" 75.0 76.0 75.0 75.0 75.0 75,0 75.0 75.0 75.0 75.0 76.0 75,0 "v.V. GENd..0,,°®o 1 48'" 750 75,0 75.0 , 75,0 75.0 75.0 76.0 75,0 76.0 75,0 75,0 75,0 "��' :Gop �; N0 49752 11-07" 42" 76.0 75.0 __ 75.0 75.0 75.0 75.0 75.0 75,0 76.0 76.0 75.0 75.0 ¢: . 38.4" 76,0 75.0 75,0 75.0 75,0 760 75,0 75.0 750 75.0 75.0 75.0 -a's �l ' 36" 75.0 76.0 75,0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 76.0 I 76.0 : T T E F /Au 30" 75.0 76.0 75.0 75.0 75.0 75.0 76.0 75.0 76.0 75.0 75.0 75.0 ,,,1%••' `� 24" 75.0 75.0 75.0 75.0 75.0 76.0 .75,0 75,0 75.0 75.0 76.0 76.0 ✓ddOaf ONALiE�ytsa`�,,� i