Loading...
HomeMy WebLinkAboutUntitled (3) \ I Pie EXTERIOR RESEARCH &DESIGN, LLC. Certificate of Authorization#9503 cIiP INIIIY ERS 353 CHRISTIAOXFORD,CT 06478 • (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL10674-R13 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida:The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity]ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity'ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 0,11.:-"!!, — • Robert J.M. Nieminen,P.E. 4 ` ' '• ••. The facsimile seal appearing was authorized byRobert t �.,+ l, Nieminen,P.E.on 10/09/2017.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity'ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity'ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classics and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTM are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration', Durations Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition Oakridge, Oakridge and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeT" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity!ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 ii El QiCTRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2 7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vkdt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein,iare Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph (V„it= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G203. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: > Berkshiree shingles require minimum five(5)nails per shingle. WeatherGuard®HP shingles require minimum six(6)nails per shingle. Devonshire'shingles require minimum six(6)nails per shingle. Y Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening,,are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt undedayment G;. Deck Feltunderlayment ,ie. Deck Selradhered �� Self-adhered % underlayment ' ✓/� WeatherLoc a ,I 1 l((y underlayment l L P ✓i rt IMP edge edge ��0 Drip edge Drip .—.\\Jfjto edge 4jli, 'I 0 Bated jfTtede ' \\\\ r211 from cave 2'-3'from cave 10, Install first Self-sealing adhesive ®Sdfal ny adhesive Starter Strip positioned along cave Insh�first Starter Snip Plus\ /positioned along cave ,� shingle with with r removed ,- 6"removed . Starter Strip shingle overhangs eaves and rakes'/I"-3/i" Starter Strip Plus overhangs eaves and rakes 1/C-3/4" b Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 I 1-RINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Standard Metric Sized Normal Mansard or Area pare Normal Mansard or Area pan Wind Areas High Wind deavan•s y Wind Areas High Wind desvanes y Ares pen vientos normeles Areas violates?�faartes Aro pars vientos normaies Areas vientos fuertas .... IAI� r _ C''%B37� , I 1 p B I 5"Exposure 5 5/8'Exposure • Exposieidn Exposition 6.2.7 Minimum Nailing—Berkshire®: Seahm strip Sealant strip iLa tka da sel adar 'O tira de sellador •<-—tel p,4---£7 -- 64-171/27-÷* e-s,• •.--y a.---..• •..--i.s�-�s t" S Yf 9'Yf 9 Yf 8 Yf f • ,e 1/2. 8 ve 8?h" 8 1/2" i T" t.J 1 p -I r Standard Fastening Pattern 6-Nail Fastening Pattern Seahnt strip !Atka de sellador /o---••fC a •4-----•a 4-------•e P . 8V 8W 8W 8Yf t, t, ii ,fi_ r Asphalt rooting cement Ca nota de techo de astaho Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 ! ' - 11 i . 1, ,i U1DFRINITY ERD ,11 6.2.8 Minimum Nailing—Devonshire": ! I I 'V— 1- 7" I 8" -I 8" I1. . 4.-22--*4 . i. 1 111 • IH'. ci .L IIII r 4,7 _ . _.... _.,,e•-.rieAlib!,-_ ....--...-..--.......m........imm-........--- :I,. 5518.exposure Sealant location '34'- Exposicion de 5.5/8 pulg Uhicacion del sellador swi 4"--"z•---"------1"-s, Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinitione Duration.Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern SunNa122fashinIng area Width Suletiait®fastening ttria WI= Na11,1VP,eal VN.H.TYP.-21 4 12" 12' 4: 1: is- tr 4...1- t •0.............. •-. ....a....a . •o....o....s....i.i ; s-VS 6-Sir . .' I ....- , Si-Sir 5412" - *eV... , . _ . Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 - _''--•".: MiriliM &Ur&Mt Irrpilllir 0 t r -- illk .‘Pw-.411.1111111.W.-- Four 1"Spot.of Aspetari Roans Cement Mansard or Steep Slope Fastening Pattern 1 [ Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/0912017 Pages of 8 Q\1=j1kINITy ERD 6.2.1 Minimum Nailing—Tru Definition'Oakridge®,Oakridge®: 4 Nail Pattern 6 Nall Pattern Esnuema con 4 davos Estfrrema coo 6 davos • T 1A1 yr 14— 12. —)01 14— 12•— 9 1^ 141— 1z- \ i "L4 55/8"Exposure Naas 5 5/8"Exposure Nails ErposFa6r1 de 65/44 Gbms Exposicinn de 55/B ping 55/8'Expostr2 Clams 55/8"Exposure Exposiasn de 66/9 ping Exposica de 5 5/8;mfg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 Sn.Noit5 fastening w.width R•4 IN/p& i• 1r +r 6118" T 1II11II 111111M1711110r: =r ___ Four 1^Spate of Aspha t Roofing Conant Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: P ' Single 544 V1.w Waft lateral CNN=ham do.godly • Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 61H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard6 HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'M Hip & Ridge Shingles shall comply with'the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge: Fig.1 49 Fig.2 !— Pr��evsaang Vane /A Median - ToPVed jSWe lfiewA RT� Hats NaNsNalls--- � / TH � \, ‘L,Itii, .it-P. TOP Lamaee . - H ' _._: i i r r o N vl i . _.\ ./\, i I 1 it i1 6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 99 Top View Prevaohg WindE—Diredbn ,\ p A Nabs~_—_).q q A Naps Naps \\\4 \ z r• 1 7' 1' IlMla i i vI EspPsnreX. \ F. Exposure /A \ Id 12" )I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page,7 of 8 Q0 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard —11°—.- Wind DirectionSealantStri Fastening Strip :.4,`:. Pattern1. Lt Aii".''' 8'Exposure i yI721 } Sealant 1i ,% Fasten 7+h° Th°' 6"Exposure Cover Exposed . Fastenerswith5 + + Roof Cement I %_- `. i2°tel 6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Ptaraiing Wird DiracGon Top View J—Direction dominant hunt Von en ane Direcdtindalriantnpn�xninanto HI" superior I"H Ncw°a f�/ 2.5.11" c00 \' 1‘16i. IIi UrensCaning SuneNan , t Naik aor .„-.A..., I I o b I` oI" r Ii" p 4 1 v v al14 oF, �Itie r V I 4 V-4: 1___,\ •. k I 1 I 12 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8