HomeMy WebLinkAboutProduct Approval (2) NIAM FILE Copy MIAMI-DADS COUNTY '® PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMIMSTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE t7A VEp "-.c%c.miamidade.po-/buildinL/ Polyglass USA Inc. 150 Lyon Drive APR 19 2018 Fernley,NV 89408 L. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County BNC-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA 4 09-0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-0601.10 Expiration Date: 09/13/16 ootmnr Approval Date: 09/15/11 Page I of 8 ROOFING COMPONENT APPROVAL Catep,ory: Roofing Sub-Category: Underlayment Material: SBS,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Smcification Description Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt underlayment 65'8"x 3'3 3/8" waterproofing membrane,glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Polystick IR-Xe Roil: TAS 103 and A fine granular/sand top surface self-adhering, underlayment 65'x 3'V/," ASTM D 1970 APP polymer modified,fiberglass reinforced, Manufacturing Location Or 65'x 3' bituminous sheet material for use as an #1 &#2 80 mils thick underlayment in sloped roof assemblies. Designed as an ice&rain shield and as a flat roof file underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP underlayment 32'10"x 3'3'/8" ASTM D 1970 polymer modified,fiberglass or polyester Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as #1 &#2 an underlayment in sloped roof assemblies. Designed as a a roof file underlayment. Polystick TU Plus Roll: TAS 103 and A non-wicking fabric surfaced,self-adhering, underlayment 65'x 3'3 3/$" ASTM D 1970 APP polymer modified,fiberglass reinforced (Facer of Membrane 80 mils thick with a high strength polyester fabric,bituminous with surface printing) sheet material for use an an underlayment in Manufacturing Location sloped roof assemblies. Designed as a metal #1 &#2 roofing and roof file underlayment. Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10"x 3'V/," ASTM D 1970 glass-fiber/polyester reinforced,with a granular Manufacturing Location 130 mils thick surface designed for use as a file roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61'x3'32/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane.Designed as a metal roofing and roof file underlayment. NOA No.: 11-0601.10 Expiration Date: 09/13/16 MIAMI-DADE COUNTY Approval Date: 09/15/11 UJO0 Page 2 of 8 PRUDU(TS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick Dual Pro Roll: ASTM D 1970 A rubberized asphalt self-adhering,glass- Manufacturing Location 61'x 3'3 3/8" fiber/polyester reinforced waterproofing #2 60 mils thick membrane,specific for use as a high temperature underlayment. Designed as a metal roofing. MANUFACTURING PLANTS: 1. Hazelton,PA 2. Winter Haven,FL EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798&G155 04/01/08 RX14E8A TAS 103/ASTM D4798&G155 11/09/09 DX23D8B TAS 103/ASTM D4798&G155 02/18/10 DX23D8A TAS 103/ASTM D4798&G155 02/18/10 NOA No.: 11-0601.10 Expiration Date: 09/13/16 �'v co�rrY Approval Date: 09/15/11 AP Page 3of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Base Sheet: One or more plies of ASTM D 226 Type 1I or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6"o.c. at a minimum 4"head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3J/2"and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. & All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit A second layer of Polystick shall be applied over the underlayment NOA No.: 11-0601.10 Expiration Date: 09/13/16 I® Appro-al Date: 09/15/11 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS,TU Plus,and Tile Pro may be used in asphaltic shingles,wood shakes and shingles,non- structural metal roofing,roof tile systems and quarry slate roof assemblies. IR-Xe,TU,and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. Exposure Limitations(days) MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven,FL. 180 180 180 180 180 180 180 Hazelton,PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe,and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof file underlayment for(direct-to-deck)tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Polystick TU,TU Plus,TU P,Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11-0601.10 Expiration Date: 09/13/16 ro�nreouHTY Approval Date: 09/15/11 Pace 5 of 3 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products.Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. MMMADE courm BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11-0601.10 Expiration Date: 09/13/16 MAMUMM POLMM Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 1 I gauge ring shank type,applied with a minimum I"metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on the face of membrane,with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251 Premium Wet/Dry Elastomenc Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic,applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the file manufacturers NOA's,must be used on all projects for pitch/slopes of T712"or greater. It is suggested that on pitch/slopes in excess of 6'/,"/12",precautions should be taken,such as the use of battens to prevent file sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. 8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyphis 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass PG500 MB Flashing Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251 Premium Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair,followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request.It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 11-0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 JAPPRO Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11-0601.10 Expiration Date: 09/13/16 MIAMoaoE COUIMM Approval Date: 09/15/11 1110,21 � Page 8 of 8