Loading...
HomeMy WebLinkAbout2017 Owens Corning underlayment\1 TRININ ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization 119503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 035470.12.10-113 FL14299-R4 Date of Issuance: 12/16/2010 Revision 3:10/10/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/1012017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Owens Corning Roof Underlayments, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.1.1, T1507.1.1 Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1 Tear Strength ASTM 01970 2015 TA5110 Accelerated Weathering TAS 110 2000 3. REFERENCES: No No Yes Entity Examination Reference Date ERD (TST6049) Accelerated Weathering 037520.08.11 08/19/2011 ITS (TST1509) Physical Properties 100274639COQ 001E 11/29/2010 PRI(TST5878) Tear strength OCF-259-02-01 12/03/2015 ITS (QUA1673) Quality Control Service Confirmation 01/25/2017 4. PRODUCT DESCRIPTION: 4.1 Deck Defense'"' High Performance Roof Underlayment is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating; meets FBC 1507.1.1 (Exception). 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FSC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Owens Corning Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: 5.6 Table 1: Roof Cover Options Underlayment Asphalt Nail -On Foam -On Metal Wood Shakes & Slate Shingles Tile Tile Shingles Deck Defense'" High Yes No No Yes Yes Yes Performance Roof Underlayment Exposure Limitations: Deck Defense"' High Performance Roof Underlayment shall not be left exposed for longer than 180 -days after installation. Exterior Research and Design, I.I.C. Evaluation Report 035470.12.10-R3 Cerlyficate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHY EVALUATION FL14299-R4 Owens Coming Roof Underlayments Revision 3:10/10/2017 Page 2 of 4 TRINITY ERD 6. INSTALLATION: 6.1 Owens Corning Roof Underlayments shall be installed in accordance with Owens Corning published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 Deck Defense'" High Performance Roof Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width for double -layer applications. 6.3.2 Always lay Deck Defense T" underlayment parallel to the eaves. 6.3.3 Mechanical attachment of Deck Defense T"" High Performance Roof Underlayment is limited to roofing nails with minimum 1 -inch diameter plastic or steel caps. 6.3.4 Slopes of 4:12 or greater: Starting at the eaves, lay Deck Defense''", lapping each course minimum 3 -inches (horizontal lap) and with minimum 4 -inch end (vertical) laps. End (vertical) laps in a succeeding course shall be staggered from those in preceding course by minimum 6 -feet. Lap Deck DefenseTm a minimum of 6 -inches from both sides over all hips, ridges and valleys. Secure with 1 -inch diameter plastic or steel cap nails placed in the printed nail areas located on Deck DefenseT"". 6.3.5 Slopesof 2;_12 to less than 4:12: Double layer application; begin by fastening a 25 - inch wide strip of Deck Defense;" placed along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Overlap succeeding courses by 25 -inches. Minimum 12 -inch end (vertical) laps shall be staggered from those in preceding course by minimum 6 -feet. 12" 12" 12" Owens Corning- 6" orning- s • r D "DEfEllf5lllm' View of Standard Securement,12-inch o.c. at laps XxAXtt.bw X]exxlBi XId XOX 3sN30a Ma 25" $UIl1"103 SUGARO .Buiui0o suemo View of Low -Slope Overlapping, 25 -inch Secure each course with 1 -inch diameter plastic or steel cap nails placed in the nailing area every 6 -inch o.c. at the overlap and 12 -inch o.c. in the center of the sheet. Secure end laps with 1 -inch diameter plastic or steel cap nails spaced 4 -inch o.c. Exterior Research and Design, I.I.C. Evaluation Report 035470.12.10-R3 Certificate o}Authorization #9503 6T" EDITION (2017} FBC NON-HVHZ EVALUATION FL14299-R4 Owens Corning Roof Underlayments Revision 3:10/10/2017 Page 3 of 4 \1 TRINITY ERD 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Silvassa, India 9. QUALITY ASSURANCE ENTITY: lntertek Testing Services NA Inc. — QUA1673; (608) 836-4400 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 035470.12.30-R3 Certificate of Authorization#9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.14299-114 Owens Corning Roof Underlayments Revision 3:10/10/2017 Page 4 of 4