HomeMy WebLinkAbout2017 Owens Corning underlayment\1 TRININ ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization 119503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Evaluation Report 035470.12.10-113
FL14299-R4
Date of Issuance: 12/16/2010
Revision 3:10/10/2017
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections
noted herein.
DESCRIPTION: Owens Corning Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/1012017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Owens Corning Roof Underlayments, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.1.1, T1507.1.1
Unrolling, Breaking Strength, Pliability
ASTM D226
2009
1507.1.1
Tear Strength
ASTM 01970
2015
TA5110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
No
No
Yes
Entity
Examination
Reference
Date
ERD (TST6049)
Accelerated Weathering
037520.08.11
08/19/2011
ITS (TST1509)
Physical Properties
100274639COQ 001E
11/29/2010
PRI(TST5878)
Tear strength
OCF-259-02-01
12/03/2015
ITS (QUA1673)
Quality Control
Service Confirmation
01/25/2017
4. PRODUCT DESCRIPTION:
4.1 Deck Defense'"' High Performance Roof Underlayment is a synthetic sheet -type underlayment comprised
of a woven core coated on both sides with a polymer coating; meets FBC 1507.1.1 (Exception).
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FSC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Owens Corning Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
5.6
Table 1: Roof Cover Options
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Wood
Shakes &
Slate
Shingles
Tile
Tile
Shingles
Deck Defense'" High
Yes
No
No
Yes
Yes
Yes
Performance Roof Underlayment
Exposure Limitations:
Deck Defense"' High Performance Roof Underlayment shall not be left exposed for longer than 180 -days
after installation.
Exterior Research and Design, I.I.C. Evaluation Report 035470.12.10-R3
Cerlyficate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHY EVALUATION FL14299-R4
Owens Coming Roof Underlayments Revision 3:10/10/2017
Page 2 of 4
TRINITY ERD
6. INSTALLATION:
6.1 Owens Corning Roof Underlayments shall be installed in accordance with Owens Corning published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 Deck Defense'" High Performance Roof Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width for double -layer applications.
6.3.2 Always lay Deck Defense T" underlayment parallel to the eaves.
6.3.3 Mechanical attachment of Deck Defense T"" High Performance Roof Underlayment is limited to roofing nails
with minimum 1 -inch diameter plastic or steel caps.
6.3.4 Slopes of 4:12 or greater:
Starting at the eaves, lay Deck Defense''", lapping each course minimum 3 -inches (horizontal lap) and with
minimum 4 -inch end (vertical) laps. End (vertical) laps in a succeeding course shall be staggered from those
in preceding course by minimum 6 -feet. Lap Deck DefenseTm a minimum of 6 -inches from both sides over
all hips, ridges and valleys.
Secure with 1 -inch diameter plastic or steel cap nails
placed in the printed nail areas located on Deck
DefenseT"".
6.3.5 Slopesof 2;_12 to less than 4:12:
Double layer application; begin by fastening a 25 -
inch wide strip of Deck Defense;" placed along the
eaves. Place a full -width sheet over the starter,
completely overlapping the starter course. Overlap
succeeding courses by 25 -inches. Minimum 12 -inch
end (vertical) laps shall be staggered from those in
preceding course by minimum 6 -feet.
12" 12" 12"
Owens Corning-
6"
orning-
s • r
D "DEfEllf5lllm'
View of Standard Securement,12-inch o.c. at laps
XxAXtt.bw X]exxlBi XId XOX
3sN30a Ma
25" $UIl1"103 SUGARO
.Buiui0o suemo
View of Low -Slope Overlapping, 25 -inch
Secure each course with 1 -inch diameter plastic or steel cap nails placed in the nailing area every 6 -inch o.c.
at the overlap and 12 -inch o.c. in the center of the sheet. Secure end laps with 1 -inch diameter plastic or
steel cap nails spaced 4 -inch o.c.
Exterior Research and Design, I.I.C. Evaluation Report 035470.12.10-R3
Certificate o}Authorization #9503 6T" EDITION (2017} FBC NON-HVHZ EVALUATION FL14299-R4
Owens Corning Roof Underlayments Revision 3:10/10/2017
Page 3 of 4
\1 TRINITY ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Silvassa, India
9. QUALITY ASSURANCE ENTITY:
lntertek Testing Services NA Inc. — QUA1673; (608) 836-4400
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 035470.12.30-R3
Certificate of Authorization#9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.14299-114
Owens Corning Roof Underlayments Revision 3:10/10/2017
Page 4 of 4