U + FL FL2569-1114
EN Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memathieu@sop re ma,ca
Authorized Signature Marc-Etienne Mathieu
memathieu@s oprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 lean-Berchmans-hllchaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative lean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert 1. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich,PE
Rt Validation Checklist- Hardcopy Received
Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL1897 2012
httn://www.floridabuildin:;.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsKQFEnckB10... 4/20/2018
Florida Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/12/2018
Date Validated 02/14/2018
Date Pending FBC Approval 02/17/2018
Date Approved 04/10/2018
-Summa ry of Products
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2S69 R14 Ii 2018 02 FINAI,ER SOPRE IA—CA UNDER!AY—KEfor use outside HVHZ:Yes &14,PAf
Impact Resistant:N/A Verified By:Robert Nierrinen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use,2.)The design pressure EL2569 RIA—AE—Z-011—OZ-FINAL ER SOPREMACA QR-QEkLAyMENTS-&Z569
—
noted herein pertains to underlayment R14.p
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems. Refer to ER Section S.6.4 for
[details.
Back [text
Contact U 2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AAJEEO employer.Copyright 2007-2013 state of Florida.::F-rLy-acy Statement:;Accessibility Statement*:Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address sed in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.
If you hraevIaany questions,please contact 850.487.1395.'Pursuant to
Section 455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emaits provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter455,F.S.,please click here.
Product Approval Accepts:
YrK E131 �E9 0
Credit'Gard
Safe
hffr)://Www.floridabuildin.g.o-ro-r,,/Pr/pr app dti.aspx?parai-n=wGEVXQWtDqsKQFEnckBIO... 4/20/2018
MEMO I etc.
Certificate of Authorization 1132455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
Merte >-
Soprema, Inc. Evaluation Report 518010.06.09-1112
1640 rue Haggerty FL2569-Ri4
Drummondville,QuebecJ2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 12:02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s),the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile sea]appearing was authorized byRobert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 02/12/2018.This does notserve as an
'`:�,3?��� „'`
., electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW Ietc. nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ti
t y
EFf
R.
ROOFING COMPONENT EVALUATION:.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments,as produced by Soprema, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth
herein.
A� � .f 5'A' G a � _^'3"—""^'^'-vrt V � � .'. "..,'^'ff:'•-.r^' ,{'f 3 �.". 3
uSection" Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
Pnti Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R2 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER2592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4.1 Lastobond TU HT�is a self-adhering, non-woven polyester fabric surfaced, SSS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch;meets ASTM D1970.
4.3 RESISTO SA SMOOTH 'PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available-in 3.3 ft x 65 ft rolls;meets ASTM D1970.
4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
WFt-_;C ETC,LIX Evaluation Report 518010.06.09-R12
Certificate of Authark0doR#32455 �ir�LDf IOP!(?�l`;jEstii,Gii-u?i ZE/FL!'r'� Vii! FI?559-;i^
Soprema Roof Underlayments Revision 12:02/12/2018
Page 2 of 8
EPV10 et2 0
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch;meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.7 EnviroShleld is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.8 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.12 RESISTO LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,
with a 36-inch sheet width;meets ASTM D1970.
4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.14 RESISTO LB1244 is a self-adhering,glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width;meets ASTM D1970.
4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
.Al If
04 Mr�^ 1
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
Wood or Slate or
Asphalt Nail-On Foam-On Composite
Underlayment Shingles Tile Tile Metal Shakes& Composite
Shingles Slate
Lastobond TU HT Yes Yes Yes Yes Yes =-Yes
See 5.5.1 ,
Lastobond Shield/Pro HT-N/
RESISTO SA SMOOTH PLY 40 No No No Yes'- Yes.
Lastobond Shield HT/Pro HT-S Yes No ` No Yes Yes Yes
EnviroShield Yes No, No "Yes ' Yes Yes
NEMO ETC,LLC Evaluation Report 518010.06.09-R32
Certificate of Authorization!#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R!4
Soprema Roof Underlayments Revision 12:02/12/2018
Page 3 of 8
Wood-or Slate or
Asphalt Nail-On Foam-On Composite
Underlayment Shingles Tele Tale Metal Shakes& Composite
Shingles
Slate
Lastobond Eaves Protection sheet/
Lastobond 195 Yes No No No Yes Yes.
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No ; ` Yes Yes'
RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes.
See-5:5.1 .
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
awss,_ Wz.� fdf �Ld�� V� to lA.n _ A
Adhesive florida Product Approval Underlayments
Dow TileBond"' FL22525 Lastobond TU HT
ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
`r Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
N ote:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of
the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave & Valley Protector, RESISTO 1_61244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on
tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional
and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,
Testing Application Standard TAS 114,Appendix J or UL1807.
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6'EDITION\!(2017)FBC NON-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12:02/12/2018
Page 4 of 8
n*,:
I' EMO J etc.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems(Lastobond TU HT only), base layer shall be
attached in accordance with FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not
address wind uplift :resistance of all underlayment systems beneath foam-on tile systems, where the
underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-
laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three(3),equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
NEW ETC,LLC Evaluation Report 518010.06.09-1112
Certificate.ofAuthorization£132455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/1212018
Page 5 of 8
NE100 eco
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5,7 Exposure Limitations:
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,
Grip-Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT-
S,EnviroShield shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using On
during loading of the roof tiles.
ry N x 2: rt ��cv�" i P� 4 A x Y���cl�'9.��a1 L���fl''�
_ _ - .. ."�.r.
Underlayment Tile Profile Staging Method Maximum
Slope
Fiat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
LastobonclTU HT
Lugged
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
MEMO ETC,LLC Evaluation Report 518010.06.09-R12
Certificate of Authorization#32455 6"'EDITION(2017)FBC NOP.'-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12;02/12/2018
Page 6 of 8
I
i
E 0 etC.
�-
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
RESISTO EXTERIOR PRIMER (if applicable).
6.3 Lastobond,TU HT,.Lastobond Shield,. Lastobond Pro HT-N,.RESISTO SA SMOOTH PLY A0, Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShield,.Lastobond Eaves.Protection Sheet,Lastobond 195,Lastobond Eco, Lastobond
Smooth Seal HT,RESISTO LB1236;Grip.-RiteEave&Valley Protector,RESISTO 1131244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.3.2 Non Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than,2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed
using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction.
For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein,and Soprema published requirements for the staging.
s
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the Installation of
this product.
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate c!f Authorization#32455 6'EDITION(2017)FEC TJ0N-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12:02/12/2018
Page 7 of 8
I
t?.
NEAA0 etc.
Contactthe noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Pl.arit Specification Product(s)
Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnviroShield,Lastobond 195,
QC(Canada) ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth
Seal HT,RESISTO L81236,PrimeSource Grip-Rite Eave&Valley
Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Colphene FR GR
Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR
Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
a r
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
MEMO ETC,LLC Evaluation Report 518010.06.09-R12
Certificate of Authorizatlon 1132455 6"EDITION(2017)F13C MON-HVHZ EVALUATION FL2569-1114
Soprema Roof Underlayments Revision 12:02112/2018
Page 8 of 8
Florida Building Code Online Page 1 of 2
I
BCIS Home 3 Log In i User Registration Hot Topics i Submit Surcharge i Stats&Facts Publications FBC Staff i BCIS Site Map I Links Search
z h id3 I
fl � i
Y,f (` I Product Approval
- USER:Public
User
Product Aoyrova Menu>Lqdvc�!-O�rA�ca[iPn Search>Application List>Application Detail
FL# i FL10674-R13
» __a Application Type Revision
Code Version 2017
Application Status Approved
I
Comments I.
Archived
Product Manufactu$r
Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
I
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
I
mel.sancrant@owenscomig.cam
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Methodl. Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
I
I
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
I �t Validation Checklist-Hardcopy Received
I
Certificate of Independence FL10674. R13 COI 2017 03 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
! ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Cade
I
htt //www.floridabuildin oro r/ r_a dtl.as x? arae=vvGEVX wtD tBNbEYSV%2... 1/15/2018
p� g- �P P 1�P_ � P Q n
Florida Building Code Online Page 2 of 2
I
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
{
Date Pending FBC Approval 10/15/2017
Date Approved i 12/12/2017
Summary of Products
FL# Model,Number or Name Description
i
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
I Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R13 11 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13,pdf
Impact Resistant:N/A Verified By: Robert 1. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER, Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.Odf
Created by Independent Third Party:Yes
i
i
Back Next
{
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to
Section 455.275(1),.Floi�ida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
1IL1, Fi:tKI
LEII
I
j C red'.Card
Safe
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw-tDgtBNbEY5 VD/o2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
`` •�'' IiN3rOXFORD,CT 06478
I 203 262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway j FL106741113
Toledo,OH 43659 j Date of Issuance:02/06/2012
(740)404-7829 ' Revision 8: 10/09/2017
SCOPE:
I
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product urider the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation)Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a cop.i of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: ,
tips.-"c j•'z`
-=;v
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 ;' Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluate.I.
2. Trinity[ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are,!being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. I
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluationj Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
J
I
I - -
TRINITY'ER
ROOFING SYSTEMS EVALUATION:
I
1. SCOPE: j
Product Category: ; Roofing
Sub-Category: I Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements!and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 ; Physical Properties ASTM D3462 2010
1507.2.7.1,13905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Enti , Examination Reference Date
UL LLC(CER9626) ; Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind.Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) ' Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) I Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) j FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
I
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
a i
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 DurationTru Definition' Duration', Duration' Premium Cool, TruDefinitionm Duration Designer Color
Collection, TruDefinition'Oakridge', Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip &Ridge
Shingles and DuraRidgeT"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
I
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS: i
5.1 This is a build(ng code evaluation. Neither TrinityiERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of tlhis product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6°1 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY ERD
5.4 Wind Classificati ln:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 toi ASTM D3161,Class F and/or ASTM D7158, Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Volt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph (Vnit=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60i feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
1
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the'roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61620-3.
6. INSTALLATION:
6_1 Underlayment: i
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:l
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4j nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions: i
➢ Berkshire'shingles require minimum five(5)nails per shingle.
WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢
Devonshire Tal shingles require minimum six(6)nails per shingle.
➢ Starter StripShingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be' in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing I Starter Strip Shingle and Starter Strip Plus:
Felt underlavment� ' Deck Felt undedaymeni Deck Self-adhered
Self-adhered =j l"ie�ertock.'
•r i underlaymenl
' r WeatherLock" -<r
1 . �undadayment tip
DripDrip edge
, Drip edge Drip—
edge I //�• edge `
-(Jails lo2
:ated __ '-3 located
2"3"from gave
2"-3'from gave
Install first
Self-sealing;adhesive Self-sealing adhesive
Starter Stripp y✓ positioned along cave LnstaJ first Starter Strip Plu. positioned along cave
shingle vAtlt tvhh 6removed—
6"removed �� \
Starter Strip shingle overhangs eaves and takes'•h L1V Starter Strip Plus overhangs eaves and rakes 114=3A*
4
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate oJAuthorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
i •-
TRINITYz E D
6.2.6 Minimum Nailing=Classic®&Supreme:
Normal i Mansard or Area para Normal Mansard or Area para
Wind AreasHigh Wind desvanes y Wind Areas High Wind desvanes y
Area para vientos normeJes Areas viontos fiiertes Area para vientos normales Areas vientos fuertes
i
r�" 2" (B) rz" �`Z viz t e'— fA)\ t--121 r.l rt. Z,. fBl pc z" "I
S'Exposure I 5 5/8'Exposure
Erposicion i Eaposicidn
6.2.7 Minimum Nailing=Berkshire®:
i
SLIant drip Sealant strip
/U Via dosdlador Lat6adesellador
t" 8 ve 9 IT j 9 Vt' 9 4Y' 8 tg B 1h" 8!" 812 ]
1„ t., 1" t J
I r
I
r
� r
I -
1
Standard astening Pattern 6-Nail Fastening Pattern
i
i
if
I
Smbrft strip
'Lo firs de s iador
I 04---DO 4-i O 0 4---D O Q----16
a'it, e,y, a"i a yi,
"
r
°
I
j 2" Asphalt rooting cement
Camanto do techo de astafto
Mansard or Steep Slope Fastening Pattern
{
I
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
i
�RIN
IYT ERD
6.2.8 Minimum Nailing,Devonshire TM:
1
1
1
1= 7" 8-t--$-t 18,t $tt t T t �1n
Na �-
gavos i
...._. 1 Nails
5.5/8"exposure
Exposicidn de 5.5/8 pulg Sealant location
Uhicaciiin del sellador 1
Ten t"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
i
6.2.9 Minimum Nailing — Duratione, TruDefinition® Duration, Duration® Premium Cool & Tru Definition®
Durations Designer Color Collection:
4'Nall Fastening Pattern 6-Nail Fastening Pattern
SUMNaiRA lastenmp are.,Addt Su*NaiMfasterdnga Wdlh
Hall Typical NmLTyplcal
14"
re_ (�'—'—� -_a __s'W___.•__. _=,e.d.�n_ e�. —r[-- a_-G�4...'..._.�._'?._a' __.._ _.��._l. o c:A.���`._" 'p-
41BT 4518` J
4118.1t5f3 --
•�
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
I �6uceNall:J fastening area adece
Nai,Typiaal
t
�ts. t 112' t
I
"..anj
Fl.
Four 1-Spob of Aspnan Raonng Cement
Mansard or Steep Slope Fastening Pattern
I
I
i
I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate oJAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
i
` I j° E D
6.2.1 Minimum Nailing—Tru Definition°Oakridge®,Oakridge®:
r
1
4 Nall Pattern } 6 Nail Pattern
Esquema con 4 clavas Esquetna con 6 ciavos
I
i
i
i� 12° �� 1 I� ,'L'—�I �•�— Y' f 12'
I -
5 616"Exposurei Nags 618"Ezposu2 NagsExposid6n de5SIG ptdg. Icfavos Expafd6ii&996/8pufg. 5 Fe"Exposure C4avW 5 618 Exposure
Exp asWa de 6919palg. Exposfcidn de 55/9pufg.
i
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SwotJa1:i1 nM.1r!j arca.Idth
-L Tw-j
1" 12"
6.716"
L
Four 1"spots of Aspnn:[Rooting content
III Mansard or Steep Slope Fastening Pattern
I
6.2.1 Minimum Nailing—WeatherGuard®HP:
i
I single Side Vim
ant
i
t
i
I
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
i
ISI 'ER
6_3 Hip&Ridge Shineles:
6.3.1 Installation of Be rkshire® Hip and Ridge Shingles, High Ridge, WeatherGuarda HP Hip and Ridge Shingles
and ProEdge Hip!& Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgeT"' Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing Berkshire®Hip&Ridge and High Ridge:
I
Fig.I 9 Fig.2
�- PICYaiIJ1/J WIIU (.
DIfCRlell % \� �•.F teP VIL59 StUCVILSJ
nets i nails ;
}��- I I ,•• 7` 1 ioP Lanlinatatpime
(P'
ExpB..
�I
� ustue
it
i
f
6.3.4 Minimum Nailing WeatherGuard®HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A Prevalling I1tM / 4 0 ` Topvhwt
a Dlrectbn I .% \•� A4
A� 1balls
'�� ROIL nous
1 I ' � t•
I I
,
Q V A
Exposure
IXPosura
A
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate ojAuthorization#9503 I 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
i Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
i
I
...-ITRINTY ERD
1
6.3.5 Minimum Nailing;ProEdge Hip&Ridge Shingles:
t
Standard
I'revaiHing a--11
Wind Direction I" Pa tertin�
Scutant Strip ,,, PatEreE
t
6°Exposure
12" ! Sealant
Fasten 7rfi� 7'/ 6"Exposure
Cover Exposed
ti Fasteners with
Roof Cement
12,
6.3.6
6.3.6 Minimum Nailing DuraRidge""Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Fra as�nE fiiixl Giro dcn Yue Top
nlpInn
Giraaiand=minantad�t}:nt Qyll- Yismsupriar ['f.�
G radon dal Minto Frrdoniinanco
"�--' ;' r 2e .o ^Osvans Canting 5rusttal'
tlnila �,� 13�-
I
Al
l
NNI-'a
i
E
7. LABELING:
7.1 Labeling shall be!in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle,wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 J R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named 0A entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
I
10. QUALITY ASSURANCE ENTIT :
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT-
it
i
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-Ra
Certificate of.Authoritation#9503 6"'EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R13
I Owens Corning Asphalt Roof Shingles Revision 8:10/0912017
Page 8 of 8