HomeMy WebLinkAboutProduct Approval _ I
Florida Building Code Online Page 1 of 2
4
k_
121
SCIS Home + Log In i User Registration Hot Topics Submit Surcharge i Stats&Facts Publications FBC Staff i BQS Site Map Llnks ' Search
9
x a'rt
QL--jProduct Approval
USER:Public User
roduct AApprovar.Menu>pcoduct,or Application Search>Application List>Application Detail
FL# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manutacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
qreq.keeler@owenscorninq.com
'Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
met.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
Validation Checklist- Hardcopy Received
Certificate of F
Independence p __L
10674 R13 COI 2017 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www_floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 VD/o2... 1/15/2018
Florida Building Code Online - Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 1113 II 201710 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant:N/A Verified By: Robert].M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section S. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.Ddf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee Fl 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
niiu- E .itEL{
Credit CArd
Safe
? a+i R.� „
http://ww-w.floridabuildinor.org/pr/pr� app dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization 69503
� n � ¢, 353 CHRISTIAN STREET,UNIT#13
RLQg� OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-118
One Owens Corning Parkway FL10674-R13
Toledo,OH 43659 Date of Issuance:02/06/2012
_ Revision 8: 10/09/2017
740 404 7829
( )
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This :Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: M
.,P.mac'•
Robert J.M. Nieminen P.E. """ The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity[ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
speciticallytor that purpose.
TRIN11YERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 61 Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section PropertV Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Kati Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 ' Asphalt Shingles:
4.1.1 Classic andSupreme are fiberglass reinforced,3-tab asphalt roof shingles.
Q
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshirelm are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 DurationTruDefinition® Duration, Duration Premium Cool; TruDefinition� Duration Designer Color
Collection, TruDefinition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&.Ridge Shingles:
4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge,WeatherGuard' HP Hip &Ridge Shingles, ProEdge Hip &Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 AccessorV Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert N(eminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-138
Certificate ofAuthorization'09503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
-,t
TMERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Volt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph (Volt=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 UnderlaVment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
> Berkshire®shingles require minimum five(5)nails per shingle.
WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire""shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlaymen[ r r Deck FeR underlayment Deck Self adhered
WeagrerLoek
"t%iy Self-adhered iL undmlaymem
VJeatlterLoch" - %
r.�t`. �underlayntcnt -���
DripDrip edge
,^ Drip edge Orip—
edge edge
-Nails located _ 4 located
2"-3'from gave
htstall first Self-sealing adhesive Snlfsevftng adhesive
Starter Stri •� lnsta3 first starter snip Pbs
pp positioned along gave With 6"removed--- po-Idoned along cave
shingle siith
6"removed
Starter Strip shingle overhangs eaves and rakes Starter Strip plus overhangs eaves and takes 2141-314^
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate ojAuthorization#9503 6"t EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
i
T1 I ER D
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area para
Wind Areas High Wind desvanes y Wind Areas High Wind deavanes y
Area pare vientos normales Areas vientos fuertes Area para vientos normofas Areas vientos fuertes
I �'
tr t-1" 121 i —121
5"Exposure 5 6/8'Exposure
Exposicidn Exposicidn
6.2.7 Minimum Nailing—Berkshire®:
Sealant drip Sealant strip
La 1 ra de sellador J La Gra de sdador
■��> oaD o!—�a 1
e
9.Srf' 9 W 91Y' 8 4t" a e?2" a 812" 8 id" ]
1
1
1
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealant strip
/La tira de sJlacbr
t�04-------*ae--a o� 04---->o t—�8 tit'
1"
A
1 -
m$ Asphalt roolhtgminent
z Cemanto do techo da astalto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-Rg
Certificate ojAuthorization 119503 6"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
MINITY ;ERD
6.2.8 Minimum Nailing—Devonshire T'
7"
I ._ Nails _
Cloves
Nails
5-5/8"exposure
Sealant loc�jation
Exposici6n do 5-5/8 pulg I
Ublcadb del sellador
7-
Ten I"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nall Fastening Pattern
s..N.ant-taninuare—idth SuraNailt fastening=a width
Nall.Typlcal Nall Typical
12. 12" —12"
77!
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
Wel.TYPI-1
12'
—2-
Ff 07 7'1
0_
F..I-Sp.t,W AIP11.1t R-1.0 C....I
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RB
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVIIZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10109/2017
Page 5 of 8
TRINITY ER
6.2.1 Minimum Nailing—Tru Definition'Oakridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattern
Esquema con 4 clavos Esquetna con 6 clavos
t• r
r r
Imo— tr —�I rr—al Imo— u•
6618"Exposure P1a17s 5 5/8"Exposur Nails
Exposid6ado65/6pidg. clavos Expostcidndeo5/8pulg. 6518"Exposure clavos 5618"Exposu2
Exposid6n:do 661$puig. Exposicvn de 65/Spulg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 2112
SutcN.ui'il IaslonlmJ arca wldN
�Naii.2ypic1
17" 1'
6.11V S.5,.r
IF71 FL7,
Z.
Fwul i"SDcls of AsPhall Rooflna Cemcnf
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
q single SricYtevim
a..
f4— �•••.'�' �`',� t� � tl/dttt®fatenraf
F;:ate • I + F5.
iYlrafar.Pbmug r bell airs
CSwsaxrEeURW01rti�fri
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorizationg9503 6'N EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINI-MERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire0 Hip and Ridge Shingles, High Ridge, WeatherGuard° HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge"" Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
FIg.1 Fig.2
Q— DPtevnlan wigWnll :�• �\.. T°PMWJ SilfcVic�v
Q,
—T Neils nils
~? 1 �
1 I Tap
P1.0 lal
Plrre
I
dr v v v
�I
�
\
��`
tib•
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.A 4' Fig.G Hip&Ridge Shingle Fastening
Prcwatltng WeW Z^ TopVIMY
Dlttctbn �```ti p\ �
Nnlls 'i A l
Noll?
�A N \ i i T'
Z.,
_
r Y V6.1 a(posure
V
Ec�sure
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of iluthorization 119503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
,4
" RINITY#ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind DirectionFastening
Sealant Strip `= Pattern t
r 6"Eupos are .. I Z-' 1_•
-- 72" I Sealant
Fasten 711? 7/'" 8"Exposure
Cover Exposed 1 J
\ Fasteners with
Roof Cement
6.3.6 Minimum Nailing—Dura RidgeT'Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
P omiing Wind Nm don Top View
Diroaion drsninnc4 dtsysnt Voe en plan
Dirocdend4l•.icntoprodctnirance E-►II- Vistasuperlar I•{�
Clou
01.cns Colnang SureFlafl'-�--- aaw
s,
1 I I
- IG
I
GIG
Ir
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior
EPORT-Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10574-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8
Florida Building Code Online Page 1 of 2
Ayry
BCIS Home a Log In !i User Registration Hot Topics Submit Surcharge i Stats&Facts = Publications 1 FBC Staff BCIS Site Map i Links Search Yi
r
!DW"
i Product Approval
#i USER:Public User
`A
roduct Approval Menu>product or Application Search>Application Lis[>Application Detail
FL# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manutacturer Owens Corning
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
qrea.keeler@owenscorninq.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the.Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017—Q-1-COI Nieminen.pddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.flori dabui l di ng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
Florida Building Code Online _ Page 2 of 2
Approval Method Method 1 O
Productpp tion D p
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
SummarV of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.Ddf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R33.odf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,FS.,please click here.
Product Approval Accepts:
'trti• El Fc_�M Ah cr 0
Gredit Cara
Sate
�y
http://www.floridabuildin--.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 03794b.02.12-R8
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the eh Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This .Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166 Florida DC4ANE1983 "_"" Nieminen,P.E.on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
speciticallytor that purpose.
TRINITY ,ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6ch Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
N
4.1.1 Classic and Supremeb are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition® Duration', Duration' Premium Cool, TruDefinitiono Duration Designer Color
Collection, TruDefinition�0akridge', Oakridge® and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip &Ridge Shingles,High Ridge,WeatherGuard® HP Hip &Ridge Shingles, ProEdge Hip &Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert N(eminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZjurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exttrior Research and Dtsign,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
r -
TRINIT"if 'ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Volt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vaed=150 mph (V„lt=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM 1137158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 UnderlaVment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire*shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire TM shingles require minimum six(6)nails per shingle.
�- Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt.rnderlayin nt -� Deck Feltunderiayment i., Deck Seifadhered
Self-adhered Weatherl ockro:,
t'� undodayment
WeatlrerLacP
r{� /underlayment i! .
Drip^ Drip edge Drip—
Drip cage
edge �'1Jr, edge
s%
--Nailslocated --Na7slorated
�.• ' Z"-3"from eave % 2'-3 tromeave
hrstall(first ' Self-sealing adhesive Sdise ng adhesive
Starter Stripp positioned along eave rtr 6rremoved r ssp Plus _ positioned along case
shingle l:'!Sh
6"removed l�
Starter Strip shingle overhangs eaves and rakes Y,=?i' Starter Strip Plus overhangs eaves and rakes 114=3(4'
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'm EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof shingles Revision 8:10/09/2017
Page 3 of 8
ERR
6.2.6 Minimum Nailing—Classic®&Supreme:
2 , e e
Normal Mansard or Area para Normal Mansard or Area pard
Wind Areas High Wind dasvanas y Wind Areas High Wind desvanes y
Area para vientos normalea Areas viontos Mertes Area para vientos normafes Areas vientos fuerres
�T IA} 7.. (7" r dBl `z t"� 11 (A) T l f'• z" -(BI
17" 17• i 127 '— / � 1218"
I
5"Exposure 5 5/8"Exposure
Ex osicion -
p Exposiaion
6.2.7 Minimum Nailing—Berkshire®..
Sealarn strip Sealant strip
r La Lira de seftador /La Ura de seNdor
b L
o —> e � mt �a • o • o a—a
1" !eve 9.! ow 8VT 8W 8W, 8t:" 8id" j
T.
A
r
0
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealant strip
La fire de cAador
---------3-o-4—>• a-*—s
%i'
1"
A
0 —
am - 1
2 Asphaft roofing cement
Cemmo do Wbo de asfalfo
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate afAuthari:ation 519503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
iED
RINITY
6.2.8 Minimum Nailing—Devonshire T":
7"
Nag
clnas Nails
A—
5-518"exposure Sealant location
Exposition do 5.5/8 pulg U6icaci6n del sellador
Ten I"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nall Fastening Pattern
summaanfaSlewnVxeaMh Sur"lf,fmterAng sea vddth
Nail,WMI Nair.lypleW
1:1 12' 12" 12"
6-1m 177
_...� .._...._....-_ _..._- _
F] F�
_j M
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening farSlapes Greater Than 21:12
N.a.Typi-
1V
6.1m
R Fq
F..,I"Sp.t.of MpWt R-fin Cement
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12.RB
Certificate ofAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
6.2.1 Minimum Nailing—TruDefinitionaoakridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattern
Esquema can 4 clavus Esquema con 6 clavus
r r
t' r
Imo-- ,< —H
6618"Exposure Nails 5 516"Exposure WIN-
ErpM1d6a de 5518 pu1g. Mayos Exposicl6n ek 5518 pulg. 5 518"Exposure clavus 5 Ste"Exposu
Eeposkidn.da 55/8 pufg. Expasid6n de 5516 ping.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
S—Wi W fasfanloe arca width
(/—H.H.TWcol
t^ 12"
6.116-5516"
.q.wr
rrour t"Spots of Asphalt Roofing Ceinc:tt
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
7' t Angle Side Wkw
.ss ;ear. e;.;.;:{ Fatlteofer Ndl an
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certificate of Authorization 119503 6'EDITION 2017 FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY!ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgeTm Hip &•Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 ^4 Fig.2
�— PtcvalQ�gWnd T•, l\�
Manionl \ To 0.1 SilleV¢ti:•
Nalsy I I. nails 1
Nails—y IIQ 1� 1
04
To Laminated
cam. I i i
i
I I =1
pwe
6" b
I
`.
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.A 4' Fig.C Hip&Ridge Shingle Fastening
Pmalling Wind
—Dllectlan � a
;� \`` •D� I I thlLa NoILs
Z..
N,\= —
Ei�sula p�
`/—\ .•; 611 Exposure
17
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization 99503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
IITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevai[iing Standard X11'
Wind DirectionFastening
Scelant Strip
6"Exposure Pattern~� �
Sealant
Fasten Th' 7,f 6"Exposure
Cover Exposed
_.\ Fasteners with
i Roof Cement
6.3.6 Minimum Nailing—DuraRidgeT'Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Rha+aiirigwind Girccdm Top View
Dir4aiandxnrrun[4��Wnnc II- lan
VistasWe uperlor I•I4.p
Dirocdmd4lvicno pr4dcmiranw
ol,ensCoining3111adairtlajh
.� claw
• lore 1_.:.-_::i
mlsy
Imo—lr �'
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-D.okania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6'EDITION(2017)FSC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8