SCIS Home i Log In i User Registration Hot Topics i Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Product Approval
0a,C-)
USER:Public User
Product Approval Menu>Product or AoPlicat Search>application List>Application Detail
m FL# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved
I
i
I
Comments I
Archived
Product Manufacturer Owens Corning
Address/Phone/Emil One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
I
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
i (419)376-8360
mel.sancrant@owenscomig.com
Quality AssuranceRepresentative
Address/Phone/Email
Category Roofing
Subcategory I Asphalt Shingles
Compliance Method. Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License i PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
Validation Checklist- Hardcopy Received
I
I
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By I
Sections from the Code
1
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=4vGEVXQwtDgtBNbEY5V%2... 1/15/2018
Florida Building Code Online Page 2 of 2
I
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated ( 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
i
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use I Installation Instructions
Approved for use in HVHZ:No FL10674 R13 II 2017-10—FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R1.3,pdf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 1113 AE 201710 FINAL ER OC ASPHALT
SHINGLES FL10674-R33.od�
Created by Independent Third Party:Yes
I
Bacic Next
I
i
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florid
a is an AA/EEO employer.Copyright 2007-2013 State of Florida.:;Privacy Statement::Accessibility Statement:;Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,.F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
w El Fs_�R CG i. Ed
Credit Cardr
Safe
E--
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
--__ Certificate ofAuthorization#9503
� ��!� � 353 CHRISTIAN STREET,UNIT#13
I OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning + Evaluation Report 03794b.02.12-R8
One Owens Corning Parkway FL10674-R13
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be inj accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: ThisEvaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance Jocumentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: ,��P
-���y1V-i7i'Q2•� i.
S
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized b Robert
t.'hlJhu i aya`, PP g V
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityJFRD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not{lave nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports arel being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
i
product. . I
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
i
r TIS ER
ROOFING SYSTEMS EVALUATION:
I
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirementsand.Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section j PropertV Standard Year
1507.2.5,R905.2.4 j Physical Properties ASTM D3462 2010
1507.2.7.1,13905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,13905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) i Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:j
o s
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire TM are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition® Duration®, Durations Premium Cool, TruDefinition' Duration Designer Color
Collection, TruDefinition'0akridge', Oakridge and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge,WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip &Ridge
Shingles and Dura�idge-'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4:3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
I
S. LIMITATIONS:
5.1 This is a building,code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZjurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. j Evaluation Report 037940.02.12-RS
Certificate of Authorization 119503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
i
II
5.
4Wind Classific tion:
_ a
5.4.1 All Owens CorninIg asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V dt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60�feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6_1 Underlayment: i
i
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4;) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
➢ We there rd H
a uar P shingles require minimum six(6)nails per shingle.
➢ Devonshire'shingles require minimum six(6)nails per shingle.
➢ Starter StripShingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
i P
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing Starter Strip Shingle and Starter Strip Plus:
"
FeltunderlaymenlJ :;ri Deck ' Fehunderiaymem Deck Self-adhered
%y Set{-ad{tered ; lne
dellaymrd
_ WeatherLock" i
i Drip edge
Drip Drip edge Drip— - x•
edge i h.� edge
Nab located
�r —PJai':sloated i' �V-3"fromeave
ti 2-3"Irum cave
Install first Self-sealing adhesive Msrat first PCu Sr1i-e-,d'ng adhesive
Starter Stripp �� positioned along eave whit 6"removed—P----e=- positloned along Cave
shingle v,ith ti .`
G°removed \
Starter Strip shingle overhangs eaves and rakes'/e-3%i' Starter Strip Pius overhangs eaves and rakes 114=3/4'
i
1
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-Rg
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION r-L10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
TRINITYED
6.2.6 Minimum Nailing. Classic®&Supreme:
o e
I
Normal ( Mansard or Area para Normal Mansard or Area para
Wind Areas High Wind desvones y Wind Areas High Wind desvanes y
Area porn vientos normal es Areas vientos fueirtes Area para vientos normalas Areas viontos fuertes
i
2- f6! r2. 1"� �^ (Al'--t �.l TI- z~ �(Bl z' 1';
I .-721 •-12i II'
5"Exposure 56/8"Exposure
Exposicidn I Exposition
6.2.7 Minimum Nailing G Berkshire®:
t
I
I
Sealant strip sealant strip
U tha da snHador La tira de sellador
i
t--i o a-------o • a • e e o
9 IfTIL9 Vt' 9 4Y' 8 Lz" 8 W, 6 tr_' 81=' r
1" 1" ," , J
r
r
1
1
i
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealant strip
La fire des ladar
1
ma—�a a---r • c a --�o a--
�,aBY1' 8'i, 8'H' r*
1"J
� Y
� e -
I
2" \ Aspliaitroofing cement
Comm da Who do asleRo
f Mansard or Steep Slope Fastening Pattern
I
I
i
Exterior Research and Design,I.I.C. ; Evaluation Report 037940.02.12-118
Certificate gfAuthoriration 119503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
iOwens Coming Asphalt Roof Shingles Revision 8:10/09/2017
I Page 4 of 8
V
T TY:ERD
RINI
6.2.8 Minimum Nailing' Devonshire"":
7" t 8n I j81, 8" T
Naas
TI. Nails
5 518" 7
exposure
Exposid6n de 5.5/18 pulg Sealant location
U6icacl6n del sellador
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition®
Duration Designer Color Collection:
I -
4,-!Nail Fastening Pattern 6-Nall Fastening Pattern
F_ ru.N.,Mwerungar..width SumNaRtWmIng a—width
12' ti.,I.Typim �Na167ypipl
r
b: - o;71 i=_i
a. —c—
G-118"
LIU,- FAI F] n I!M D 71 R
Standard6-Nail Fastening pattern
Fastening for Slopes Greater Than 21:12
fl rr gun.gp�eai
IV
n F
Four 1'Spam of Asphalt Rmfinn Cement
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.L.C. I Evaluation Report 037940.02.12-R8
Certificate of Authorization#950 6'EDITION(2017)FSC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
l
TRINITYED
6.2.1 Minimum Nailing—TruDefinition'0akridgeO,Oakridge°:
f
i
4 Nall Pattern I 6 Nail Pattern
Esauema con 4 ciavos Esquenra con 6 clavos
I
I
1' 1
/Y'
I
i
5618"Exposure Wails 5 liff,Exposure Wails
FrposidiJado56/8pulg. IClavos Exposlcldndeb6/8paig. 1118"Exposure Clavus 5518"Eaposura
Expmfd6n de 55/8 pulg. Exposition de'6 5/8palg.
I
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes GreaterThan 21:12
Suollail L tatluNng amu width
Nail.Typic at
t" 12" i 12" 1"
l c —
6'115.5•Sflt" !
I �
iFour 1"Spot.of Asphmt Rooting Gomont
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
i
I
i
I�
1
ngle Side View
V9V1rf0 bre" '
l
i
I
i
I
i
i
Exterior Research and Design,LLC. I Evaluation Report 037940.02.12-Rg
Certificate of Authorization#9503 i 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1313
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
I -
T9I ''ER
6_3 Hip&Ridge Shingles:
6.3.1 Installation ofBerkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and ProEdge Hipp& Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge. Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall bi� in accordance with the manufacturer's published requirements, but not less than FBC
I
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing Berkshire®Hip&Ridge and High Ridge:
I _
Fig.I 4 Fig.2
F— PreviJl9lgVdnd
Dlrarllan j \,,` \\ \l fapViev StleViftv
nails ;
04 I i� Z•.I t {
\/ ( A\` Tap PI¢natal
�\
\ I I
I =1 V Y 7 V =1
I F—
\ „X �� \
I
i
6.3.4 Minimum Nailing WeatherGuardO HP Hip and Ridge:
Fig.A 4, Fig.C Ilip Ridge Shingle Fastening
PrcfallIng ilmd \\ �.` Top Vlevi
Q—alrcctbn !
\ A\�
Galls
NOW
T.
%�\ I �� I i I 1' 1•
0-r-
77
�7 1u�
v v v
f Exposure
-- S Exposure
17, s�
I
I
I
I
Exterior Research and Design,LLC. I Evaluation Report 037940.02.12-R8
Certificate afAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
_TRS ERD
6.3.5 Minimum Nailing ProEdge Hip&Ridge Shingles:
Standard
Prevailling Fastening
Wind Direction Sealant Strip pattern
2"
6"Exposure
Sealant
u
Fasten71[2" 61'Exposure
Cover Exposed
Fasteners%'Iith
Roof Cement
6.3.6 Minimum Nailing L DuraRldge'"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
F a'-il-CW-idTop View
EiT0CQkn Vue Ell PLY1
Riv.imdanijRMO 6A 0:41( Vim wpi:rlsr I'
Dimcdon dol vicnio prockmitonto
o§�
c1l U
2'W
------ ? Omits Coining iirfiaa'
flail;
.........
--N
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
i
Table 1507.2.7.1 J R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building g Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named CA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements. I
10. QUALITY ASSURANCE ENTItY,