Loading...
HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH&DESIGN, LLC. JUCertificate of Authorization#9503 TRINITY,ERDFILE C 0 PY 53 CHRISTIANOXFSTREET, UNIT#13 ORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway F1.10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: — GP,r s4���/,• . YJ �.K W-: Robert J.M.Nieminen,P.E. f...... q The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 I 11-�, Nieminen,P.E.on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classics and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshires are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Durations, TruDefinitions Durations, Duration Premium Cool, Tru Definitions Duration" Designer Color Collection, Tru Definitions Oakridges, Oakridge and WeatherGuard6 HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshires Hip & Ridge Shingles, High Ridge, WeatherGuardm HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeT' Hip& Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1313 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones Up to Vmd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire shingles require minimum five(5)nails per shingle. WeatherGuard�HP shingles require minimum six(6)nails per shingle. Devonshire'"shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlsyment Deck Felt endertryn ent Desk Sefedtered weathed.0" Self-adhered uneerlatnnanr WeatherLocV urdedayment Drip 011100 Drip_ Drip edge prig—. edge edge Nails located fYaie buaee r-0'fiom acre 2"-3"from save Install first Self-sealing adhesive k"Ad$rot Starm S*P4a Ssftwaitq sdherve Starter Strip positioned along eave udtl"S. posidond aloap ewe shingle withStrip shingle overhangs eaves and rakes \\ 6"removed Starter r Starer&rip Plus ovwMngs ares and rata �tl4'_ V /�"-h" Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 QOTRINI-FYIERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pem Normal Mansard or Ana pin Wind Aran High Wind dnsvanas y Wind Areas High Find dasvanes y Atoa para viaattos non ies Aress visntos ANWres Ana para vientos nomolos Areas viantos latartss Ur.pr U►1 r t r OZ 2' t' t" (AI t' +rim Ir Exposure 5%4'Exposwe Eirposioldn Exposiai" 6.2.7 Minimum Nailing—Berkshire®: Seahrt ship Sealant strip La Un ds sdodor La tira de Wador 814' 9 Yf 1 9 Yf 1 9 W } 9 Vi" 8 2" 814" 8 VI" 1 r �'J t• VJ s s s Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip Le Ora ds aatiador r B Vf 8 Vf 9 Yf 8 Yf P a n 2' Asphak roofing cement Cannata da taeho&i stab Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization x9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 ",, TRINITY I ERD 6.2.8 Minimum Nailing—Devonshire'": 1. 7" 8" 8.1 8' ' �w • Clam a Nalls 5.5lI!'expowrc Sealant locafbn Exposiadti de 5 6/8 pulp Sealant del sellador SW -----• Ems: Ten t"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition® Durationf Designer Color Collection: 4-Nall Fastening Pattern 6-Nail Fastening Pattern s1eeRM®ras'neq area wMlw auprraeao to tKWV aea wm" tae.typril N.M.lvpr+i t^ tr tr + tr i r +r r aur sen ovr saw F] F1 F� Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greats Than 21:12 fu•NMI"Wtaaq—wMe "t rypr I.i it I +r e•+n sS's role+•Spat of MOM Rod"Cw Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 TRINITY ERD 6.2.1 Minimum Nailing—TruDefinition Oakridge°,Oakridgel: 4 Nall Pattetr 6 Nail Pattern Esqua w con 4 claws fsquema colt 6 6avos t„ t. 1' T 12 —7��rA rz 5 519"Expowre Nair 5 5/8"Exposure Hails Exposiadnde65/8ptdg clams FYposiciondo66/8pulg. 55/8"Exposure lavas 66/8 Exposure Fxposia6n de 6 6/8 puig b pasiaon de 66/9 pulg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 sweHe�•r.•ronirp.r..rr.0 NYS typ101 r .r r Ffa^ �r ra.t'{ph an.o..rr ao.r.q e...+ Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard'HP: ilvbrb l Mal t� _' 7 s{ :i•: ''d• FraiwaarTl..t�+wllhr Cl....a In li..a do fl/.rlfn Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization 89SO3 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 ��TRINITYIERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 9 Fig.2 t— PI•vdrp Mind p•adrn p TopV§m SMaIA— �s—��. A Nails Nair r" T Top Ta0 r 1 A 1 1 1' Pi, 1 I q I I I i I r r it l�- r ir �1 �I I 1 1 I I I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.A y v Fig.C Hip&Ridge Shingle Fastening WWWTopYrw �_all'sCt� A A I I p � � Nslr IYIr p i I 7 I 1 T Z A � I I � • n 611 Eaposuw I 17 Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ERS 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevaiing Standard —11'� Wind Direction seahnt strip F"t*ni g 6.EXPUM Pat 12' s..lnt Fobr,71h' 71k' 8'Exp""vre Cover-t- with Roof Clowt 6.3.6 Minimum Nailing—DuraRidge'"Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. lAa.aiGy Wk,d Diratis, Top V%w '—Dinmaa bniaaata&A Tmt "W"^�'^ Dirraeen dtl*No wawr,i,r,o I vim uyer,o. I- 41 2W - -- ---- -- a". !It>V t � . o....cotrr�srtNaT I I I •I� t sl€g s: I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued October 11, 2017 1637 515`Street Tuscaloosa,AL 35401 (800)489-2391 www.msaroof.com Manufacturing Location: Tuscaloosa,AL FILE COPY Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION AND LIMITS OF USE QUIK-Stick Ice&Water QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment Granular constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Granular is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice&Water QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment Sand constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick HT QUIK-Stick HT is an ASTM D 1970 self-adhesive underlayment constructed from SBS (High Temperature) modified asphalt with a fiberglass mat reinforcement and poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61- ft and has a nominal thickness of 60 mils. QUIK-Stick HT is to be used as prescribed in FBC Section 1507.1.1. QUIK-Stick HT is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. MSA17001 FL17401-R4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK MID-STATES ASPHALT AND CANT STRIP,INC Self-Adhering Underlayments TECHNICAL SERVICES, LLC QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from (High Temperature) SBS modified asphalt with a fiberglass mat reinforcement and poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Film Surface) modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6"end laps staggered min.6-ft.from preceding course. It is permissible to back nail the underlayment 12-inches on-center as needed(nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 —QUIK-Stick HT only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: QUIK-Stick HT shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: MSA17001 FL17401-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. ' CREEK MID-STATES ASPHALT AND CANT STRIP,INC Self-Adhering Underlayments TECHNICAL SERVICES, LLC GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) BWR-514-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-522-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) BWR-534-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) PRI Construction Materials Technologies(TST5878) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a MSA17001 FL17401-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK MID-STATES ASPHALT AND CANT STRIP,INC Self-Adhering Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. %``�11rtr,111111ii % '� RA C E N 2017.10.11 No 74021 11 :41 :31 -04'00' STATE OF 4 O R 1 O \.��� Zachary R. Priest, P.E. � S'• C?�� Florida Registration No.74021 14 S/pNA�E ��` Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT MSA17001 FL17401-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein.