REPLACE DOOR IN 1 OPENING ONLY.
LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED UNDER THIS PERMIT.SHUTTERS
NOT REQUIRED PER FBC,6TH EDITION(2017), EXISTING BUILDINGS,707.4,EXCEPTION#2.
SEE GLAZED AREA CALCULATION SHEET FOR OPENING RELATIVE PERCENTAGES.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 32 80 17.78 4 37.8 -41.0 FL12769.6 50.0 -50.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH#10 WOOD SCREWS INTO WOOD STRUCTURE ;
WITH A MINIMUM 1 1/2"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30%OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 10 IN
CECIL RESIDENCE
5803 SPRUCE DRIVE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA