Loading...
HomeMy WebLinkAboutUntitled (5) EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 I 353 CHRISTIAN STREET,UNIT#13 R TRNIE � D OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-R12 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. - CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen,P.E. +i,FS':•: ..•s�• '` Thefac041e/2016.Thisldo doesnwatservelzednyRobrrtMemingn, r . � P.E.on 04/18/2016. not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 , ' •1' document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity'ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinityI ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. r . - c1RINIED ROOFING SYSTEMS EVALUATION: 1. SCOPE: • Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 • UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Durations, TruDefinition* Duration*, Durations Premium Cool, TruDefinition" Durations Designer Color Collection, TruDefinition*Oakridge*, Oakridge and WeatherGuards HP are fiberglass reinforced, laminated asphalt roof shingles. • 4.2 Berkshire Hip & Ridge Shingles, High Ridge,.WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTM Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3. Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity'ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2. This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 2 of 8 r TRINITY i ER® 1 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (VA=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are - acceptable for use in all wind zones up to Vasd=150 mph (Via=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: > Berkshire*shingles require minimum five(5)nails per shingle. > WeatherGuard HP shingles require minimum six(6)nails per shingle. > DevonshireTM shingles require minimum six(6)nails per shingle. > Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: I Felt underlayment 'mss. Deck Felt underlayment % Deck lettered rt: Self-adhered underlayment-''''' Weathercock° underlayment • .l Drip edge Drip Drip edge ele,\ 0O Na�lslorated Nails located n from eave ® 2"-3"from eavelie Install first Self-sealing adhesive Srlfae4ing adhesive Starter Strip positioned along save Instal first Strip Plusle pos;tumed along save shingle with ved 6"removed \ , a Starter Strip Plus overhangs eaves and rakes 1!4"-3/4' Starter Strip shingle overhangs eaves and rakes W-fe Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 TRINITY ERD 6.2.6 Minimum Nailing—Classic®&Supreme: azza Normal - Mansard or Area pare Normal Mansard or Area pare Wind Areas High Wind desvanes y Wind Areas High Wind deavanes y ' Area pare vientos-normales Areas viontos fuertes Area para vientos normales Areas vientos fuertes 2" (B 2" 1" • • • • • WEI= 1.1111111111 5"Exposure 5 5iti"Exposure Exposicidn Exposieidn • 6.2.7 Minimum Nailing-Berkshire®: Sealant strip Sealant strip La tirade sellador /La tirade sellador 4--► •,l---s- t=om• • --.•e- • •e--.•��• i" 8Yzt" 9.Y2 9Yt' SW } "8?h" 81" 8W' 8Vi" ? 1 i.. i.. Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip La tire de sellador Yf 54fi tit' 9 K t" a 4111111144, • t. 2" Asphalt roofing cement Cemento de techo de estate Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 • Page 4 of 8 TRINITY ERD 6.2.8• Minimum Nailing—DevonshireTM: 1'. 1 7" $„ „,, 1 g f 7 —1 --1 n I d ill 1111111111/...- IV gili ��� 5-5/8”exposure Sealant location ""'` � ��� '`„ Exposition de 5.5/8 pulg Ubicacion del sellador 5;T; I Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool &TruDefinition® Duration® . Designer Color Collection: • 4-Nail Fastening Pattern 6-Nail Fastening Pattern SureNa1l110 fastening area erdth NM,Typicn E ysuaaan �s rc -.� .»canwiKnc.�•.;,.�::.__ s+ StueNadmf..a...ste.nin.gNomar,3reaTyaw.plidc,nN e-tar ske^s,a's ^l am,al I1 Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 2112 Sur0Nagt fastening area WWII) Nad Typrcol ,P 12. t' .:.+nom"�s`��ms;...........'� tr,„{wu�fri°'rv `w`�'.. —_'— Four 1"Spots of Asphalt.Roofing Osman Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 5of8 TRINITY ERD 6.2.1 Minimum Nailing—TruDefinition®Oakridge®,Oakridge®: '4 Nail Pattern '6 Nail Pattern Esquema con 4 claws Esquema con 6'clavos 1 7I 12" _4.1 _tom 12 601— A IMEllik‘WAWIME_y. 5 5/8 Exposure 5 5/9"Exposure Nails Nails ExposidgrrdE55lSputg. Claws Exposition de55/Bpulg. 55/8'Exposure Claws 5518"Exposure Exposkion de 55/8 putg. Exposicinn de S 5/9 pulp. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Stopes Greater Than 21:12 SLR Otietiki fastening area wrath (rRail,Typical 1" 12" t 12" 1" s t :•.�„c�"wu-s--":-,.. - .ems . ....a-.n.---;,av�---:- T &1t8"5 " IK—T2" Fact t^Spots otAspnatt Routing Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuarde HP: 1• 1 Bingle olds View vir Vista!atm' Fiat i nrnxo gh WI Lbw • Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 6 of 8 e i TRINITY ER® 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge,WeatherGuard® HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of DuraRidgeTM' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 -4 Flg.2 <— Ptev ling Wed TaPblew SilleUiew. Dileaian \ \io \A\ Nags 94 Nails Nals "� �i( .2' TopLanirrated- 2 Icy A. 4 I��! Piece \ I I I \ i v r r 1 LI 8'—f 8 E posure / v Albk\ \ \ � ,z- 'I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 4 4 Prevallleg Wind ///�\\ \\ Top Ulow -Dlrectbn !/ \\ ,o\ Nails-------y44 \ .io\1 \\\s'� Nails Nails 4 4 ll AA 1 I I —1-1 rim •-A-• ~ A v tExposure \ \ G' Exposure /i/\ \ .\ v 11 72 Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization 119503 F110674-R12 Revision 7:04/18/2016 Page 7 of 8 • • TRI ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11"—� Fa Wind Direction Sealant Strip Pattern 41---- G.Exposure 1""I f*.- 1-1 I:1' S 12' I � Sealant '4111111111111W _- Fasten h 7,/2. 6'Exposure � �� Couer Exposed I 1 Fasteners with Reef Cement 1.--t2" �: 6.3.6 Minimum Nailing—DuraRidgeTM Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. ProraiinBWind Dimas-en Top Vu on plan Diraaiondatninuntadi-suit Dirooi ndol viH1' Y(stasupertor I'IH no prod:minsntA VW - Clau rlaib ._ ... V. .2- , 4. ;• OvxnsCaningSund734t • r'�9 C Brat ; 1 x 1 1 IIi •:.%, L I ,... ,,......„, „, A \ . -14 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. ' 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 8 of 8 • n . MIAMI COUNTY �.. ._' MIAMI-DADE NY ' ‘14 PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www•miamidade.!ov/economv Owens Corning Roofing and Asphalt,LLC One Owens Corning Parkway S Toledo,OH 43659. SCOPE: S This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Duration®,Duration®Premium,TruDefinition®Duration®,and TruDefinition®Duration® Designer Colors Collection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. . ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0309.01 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. 04111 NOA No.: 16-0425.01 MIAMI.DADE COUNTY Expiration Date: 07/19/21 APPROVED Approval Date: 07/21/16 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofmg Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood • SCOPE This approves a roofing system using Owens Corning Duration®and Duration®Premium asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Product Description Duration® 13 1/4"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced _ Manufacturing Locations#1,2 four tab asphalt shingle with continuous bead of sealant. Duration®Premium; 13 1/4"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced TruDefinition®Duration®; four tab asphalt shingle with large nail TruDefinition®Duration® area with continuous bead of sealant. Designer Colors Collection Manufacturing Location#1,2,3,4 Duration® 13 I/4"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced Manufacturing Location#1,2,3 • four tab asphalt shingle with dashed bead of sealant. Duration®Premium; 13 I/4"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced TruDefinition®Duration®; four tab asphalt shingle with dashed TruDefinition®Duration® bead of sealant. Designer Colors Collection Manufacturing Location#1,2,3,4 MANUFACTURING LOCATION 1. Jacksonville,FL 2. Memphis,TN 3. Savannah,GA 4. Irving,TX NOA No.: 16-0425.01 MIAMI•DADE COUNTY APPROVED Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies,Inc. OCF-157-02-01 TAS 100 10/26/10 OCF-102-02-01 TAS 100 11/12/07 ' OCF-156-02-01 TAS 100 10/26/10 OCF-163-02-01 TAS 100 12/10/10 OCF-164-02-01 TAS 100 12/10/10 OCF-098-02-01 TAS 100 02/22/07 OCF-099-02-01 TAS 100 02/26/07 OCF-102-02-01 TAS 100 11/12/07 OCF-172-02-01 TAS 100 05/26/11 OCF-179-02-01 TAS 100 02/02/12 Underwriters Laboratories,Inc. 07CA39536 TAS 107 11/11/07 03NK04954 TAS 107 03/28/03 03NK04954 TAS 107 03/11/03 10NK13947 TAS 107 11/12/10 11CA15662 TAS 107 05/27/11 11NB21712 TAS 107 02/18/12 07CA02026 ASTM D 3462 01/26/07 12CA12180 ASTM D 3462 03/01/12 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2., Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail'B',attached. LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". CECOUNTY APPROVED NOA No.: 16-0425.01 MIAMI•DADE COUNTY Expiration Date: 07/19/21 APPROVED Approval Date: 07/21/16 Page 3 of 6 BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. DETAIL A f EDGE OF ROOF 13" • • • THIRD COURSE L-61 2 SECOND COURSE • • • • • • • • FIRST COURSE • NOA No.: 16-0425.01 MIAMI•DADE COUNTY APPROVED Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 4 of 6 .-. " Vow ut T- O NA, o o ttill Z° AA ..1o , Zalal L, P it" a 0 C Al g F A C SureNail Fastening area Z Area de fijacion SureNail O OP h Z i ray . R Fastening area SureNail Area de fijacion W W u) ureNau• SureNau Su.eNau• sureNau Fastening area for A A A -O.' Mansard or Steep Slope Area de fijacion para mansardas —_,_Y o pendlenfes agudas 11 0 •- P o , 8 A a Q . ...H W GI U ai, W O Da a E Q E • • 8 Nail Pattern Esquittna'do 6 divas 9 . , i r. ,t. 1.1 ,,, I Nails X1I 6 .,31, a �`' 4!! * MAXIMUM SLOPE 21:12 Fastening for Slopes. Greater Than 21:12 SureNalt fastening.area width Nat,Typical 1" 12" l 12" 1" 0&) troms-m ' - 4►B .[ r :.i,.. r in tea," . ,ur , 1,.," 6x118"" 5-518" ....„ , . , , E4i 7( „, 2 ,,,,,,,,,,,,.....,- Four 1”Sputa of Asphalt Roofing Cement-. SLOPE GREATER THAN 21:12 END OF THIS ACCEPTANCE NOA No.: 16-0425.01 MIAMI•DADE COUNTY Expiration Date: 07/19/21 APPROVED Approval Date:.07/21/16 Page 6 of 6