HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4
ProfessionalBusiness & Regulation
UMMMUM
SCIS Home I Log In I User Registration i Hot Topics i Submit Surcharge ! Stats&Facts i Publications FBC Staff 1 BCIS Site Map Links Search
Or
Product Approvalf�USER:Public User RECEIVED
Product Approval Menu>Product or Aoolication Search>Application List>Appl ratron Detall
APR 2 5 2018
FL# FL22378-R2
Application Type Affirmation ST. LUCie County, Permittina
Code Version 2017 —
Application Status Approved
Comments ILE C 0
Archived
Product Manufacturer Masonite International
Address/Phone/Email 1955 Powis Road
West Chicago,IL 60185
(800)663-3667
sschreiber@masonite.com
Authorized Signature Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
®I affirm that there are no changes in the new Florida
Building Code which affect my product(s)and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity OYes 0N ON/A
Product Approval Method Method 1 Option A
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3 M6m9%2fK8XPI... 4/26/2018
Florida Building Code Online Page 2 of 4
Date Submitted 12/01/2017
Date Validated 12/01/2017
Date Pending FBC Approval
Date Approved 12/06/2017
Summary of Products
FL# Model,Number or Name Description
22378.1 Stormguard Fiberglass Side-Hinged 6'-8"Opaque I/S Single Door
Door Unit
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL22378 R2 C CAC NI007077.07 .odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+60/-65 Installation Instructions
Other: Evaluated for use in locations adhering to the FL22378 R2 II FL0170.Ddf
Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements do not exceed the Created by Independent Third Party:
design pressures listed.3'-0"x 6'-8"max nominal size. Evaluation Reports
Hurricane protective system is NOT required.See DWG-MA- FL22378 R2 AE 514010A.odf
FLO170 for anchor details and water performance where FL22378 R2 AE 514014A.Ddf
required. I Created by Independent Third Party: Yes
22378.2 Stormguard Fiberglass Side-Hinged 6'-8"Opaque O/S Single Door
Door Unit
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL22378 R2 C CAC NI007077.07 .Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+60/-60 Installation Instructions
Other:Evaluated for use in locations adhering to the FL22378 R2 II FL0170.Ddf
Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements do not exceed the Created by Independent Third Party:
design pressures listed.3'-0"x 6'-8"max nominal size. Evaluation Reports
Hurricane protective system is NOT required.See DWG-MA- FL22378 R2 AE 514010A.udf
FLO170 for anchor details and water performance where FL22378 R2 AE 514014A.Ddf
required. Created by Independent Third Party:Yes
22378.3 Stormguard Fiberglass Side-Hinged 6'-8"Opaque I/S Single or Double Door w/or w/o Sidelites
Door Unit
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL22378 R2 C CAC NI007077.07 .)df
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +50.5/-50.5 Installation Instructions
Other:Evaluated for use in locations adhering to the FL22378 R2 it FL0170.12df
Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements do not exceed the Created by Independent Third Party:
design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports
Hurricane protective system is NOT required.See DWG-MA- FL22378 R2 AE 514008A.Ddf
FLO170 for anchor details and water performance where FL22378 R2 AE 514012A.odf
required. Created by Independent Third Party: Yes
22378.4 Stormguard Fiberglass Side-Hinged 6'-8"Opaque O/S Single or Double Door w/or w/o Sidelites
� Door Unit
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL22378 R2 C CAC NI007077.07 .Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +55.0/-50.5 Installation Instructions
Other:Evaluated for use in locations adhering to the FL22378 R2 II FL0170,odf
Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements do not exceed the Created by Independent Third Party:
design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports
Hurricane protective system is NOT required.See DWG-MA- FL22378 R2 AE 514008A.Ddf
FLO170 for anchor details and water performance where FL22378 R2 AE 514012A.Ddf
required. Created by Independent Third Party: Yes
22378.5 Stormguard Fiberglass Side-Hinged 6'-8"Impact Glazed I/S or O/S Single Door w/or w/o
Door Unit Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL22378 R2 C CAC N1007077.09 .Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +55/-55 Installation Instructions
Other: Evaluated for use in locations adhering to the FL22378 R2 II FL0172.odf
Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements do not exceed the Created by Independent Third Party:
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgs3 M6m9%2fK8XPI... 4/26/2018
u�
1 MASONITE. 149"MAX OVER&L FRAME*?DTH 10
21" MAXQ
0
STORMGUARD FIBERGLASS DOOR UNIT D36.375" MAX..L.O. PANEL WIDTH MAX. � �U)
6'-8"DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH 2 J
� U)
GENERAL ® ® ® ® U
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE ,,, 4
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM g
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, =
DOES NOT EXCEED THE DESIGN PRESSURES LISTED. •o U)U
2. THIS PRODUCT DOES NOT REQUIRE THE USE OF m r C))
A HURRICANE PROTECTIVE SYSTEM (SHUTTERS).
3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 <p LLJ
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. -j
O x
4. PLASTICS TESTING: w
TEST DESCRIPTION DESIGNATION FACING LITE FRAME a
SELF IGNITION TEMP ASTM D1929 752 'F > 650'F 842 'F > 650 'F
RATE OF BURNING ASTM D635 0.56 IN MIN 1.28 IN MIN 'S
M K DENSITY ASTM 02643 53.4X 70.2X
3
TENSILE STRENGTH' I ASTM D638 I 3.2X DIFF 1.8X DIFF
5. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): m W
TEST DESCRIPTION DESIGNATION RESULT
SELFIGNITION TEMP ASTM D1929 779'F > 550'F LI
RATE OF BURNING ASTM D635 0.0 IN MIN
SMOKE OR
o
DENSITY ASTM D2843 39. A�1e11d911b11A11 0
TENSILE STRENGTH- ASTM D638 3.6X DIFF O
• COMP SILE STRENGTH AFTER WEATHERING DOUBLE DOOR UNIT WISIDELM a
OURS N ARC METHOD I �t
0.
Do ygm
lcn
a _
13 ® 13 ® 1313 ® 13 1313 1313 1313 ® 13
W W
REUj
• CL D
v o v1
• F
WOZ=V UI
DOI 0 1100 00 11001 100 11 11 ¢ aZ
.1 �-�Jl 0 0 10
��U1p
0 1
SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT W SIDELITES DOUBLE DOOR UNIT W/SIDEI M W
.._ WITH S1DE't lTE WITH , N m cj
N N o
STRUCTURAL WHERE WATER INFILTRATION PERFORMANCE IS a'n
DESIGN PRESSURE RATING REQUIRED TO BE 15X OF DESIGN PRESSURE
CONFIC MAX WIDTH INSWING ALL OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S T4 0 S HIGH DAM 0 S
X 37.5 +60.0 -65.0 +60.0 -60.0 N A +25.0 - .0 +40.0 -40.0
. .. .. ... . +2 +60..0 . +60. -60.0%X 74 +50.0 50.5 +50 - N 0
AEJC3 v m a z. . +55
55
5. -505
0X0 55.0 - 0.OX or XO 75 N -50.5 40. 555ale 419107
5
OXXO . +
SCALE N.T.S.
TABLE OF CONTENTS owe.Ily, SWS
SHEET # DESCRIPTION CKK.Br:
1 TYPICAL ELEVATIONS h GENERAL NOTES KURT BALTHAZOR DRAvANo Ho.:
2 ANCH R NG LOCATIONS a FLORIDA P.E. DWG-MA-FLO170-07
3 IANCHORING LOCATIONS do DETaLS 156533
SHIM 1 Of 3
u)
¢ Do
—
� q�
6' "EE DETAIL 3' 3 B"
3• J
I I I I I I I I o3'-� �. FZ= 2
n -
TF
In
Mn
aLo
SEE DETAIL '-3
N N D.
Y J
SEE DETAIL
SEE DETAIL �1 _ - �w w - - 'C'
.C. - lA g w ._
to
A E+
- 8' 8" 6 3" all
s' I �� I II I o
Ir
3'- - 3' 3_ 3' 8' 8' Dal
3' 3• 3-
6 SEE DETAIL 6' #8 x 2" N� 3
'F' ASTRAGAL RETAINER BOLT HOLE
MUST BE DRILLED THROUGH
#10 x 5/8" THE THRESHOLD & INTO THE w
#8 x 2" \\-� I Qi;" STRUCTURE DEEP ENOUGH ¢�
#10 x 5/8" FORA 1.375" THROW -:3:);
a
#8 x 2" #10 x 1" DETAIL "E" ASTRAGAL a
#10 x 2-1/2" ATTACH ASTRAGAL RETAINER BOLT DETAIL "F" ASTRAGAL p o Si
w0=U 45-
0
110 x I" STRIKE PLATE TO FRAME ^1D S�0,� Z
10 x 5/8" AS SHOWN.
# DETAIL "C"
DETAIL "D" mmNQ
N N p
0.982 0.124'HEAT STRENGTHENED DECORATIVE INSERT 0.124'HEAT STRENGTHENED DECORATIVE WERT O�
1 1( (OP�K) O.D90'SW=(NOA 15-1201.11) (OPTIONAL)
1.375' �J D.OBO' .124'((NDA STRENGTHENED
_ .012t'TEMP. 0.124'HEAT STRENGTHENED
0.124"HEAT STRENGTHENED - .0124'TEMP.
T T 1/2'BITE 1/2'BITE p U m¢Z
INSWING THRESHOLD BUMPER 0/5 THRESHOLD
"`; •' :t�7 °, DATE 4/9/07
1 1 1 DOW 995 ,• DOW 995 DDW 995 :' DOW 995 9 N.T.S.
1.482' T.75' 1.047' 1.437' DWO.B1: SWS
T T T nDa>JOe cm.B.:
TYPICAL GLAZING DETAIL AI TFRNATE GLAZING DETAIL °FAWM NO.:
DWG-►?-PLD
7-SERIES_ /S THRESHOLD HIGH DAM 0/S THRESHOLD T4 O/S THRESHOLD IMPACT RATED GLASS IMPACT RATED GLASS —
sl�r Z a .,3�
SEE DETAIL
3- 6" 6' � 00
'E' SHT. 2 _ 3' 3'
31
rk
I I I I ( I I I I I Q
1 -
s•
O m � LA
nn o 04 _ _ a p Q
w W =
a SEE DETAIL U)U
}"D' SHT. 2 - - '^ Z L0 F-
�
r--W
SEE DETAIL w o
"C_ SHT. 2
n N O
A A a G C H B
6
i0
r6- ' - .' "
r
I I II 11 I m��
1 N
3' L3. =is
Calfiaafvltb. IdklldlrobNhM SEE DETAIL 3" 6 3-6 8' 3'6w Ib�l- o �2
` "F" SHT. 2 6.
HARDWARE SCHEDULE a a
3:iat
ATTACHMENT DETAIL 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND Inoicn6lm
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, AT 5-1/2" CENTERLINE.
SIGNED AND SEALED BY ROBERTO LOMAS, PEt 25' 2. 4" X 4" FULL MORTISE BUTT HINGES. rn
(FLORIDA #62514) WITH THE LOWEST (LEAST) M,ry e x
FASTENER RATING FROM THE DIFFERENT FASTENERS MAX" t'xt/2" CORRUGATED #lOx2" WOOD SCREW ww
CL
BEING CONSIDERED FOR USE. JAMB, HEAD, AND SHIM 3' FROM EACH END 6" FROM EACH END »p to
7.25' e." ; '* AND T OC AND 12" OC r N a O_
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CL-I I— MIN
#10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. 0.25" wo=�
A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACHsMAX
SRC a
ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2 cl—� CAULK
WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE TYPICAL MASONRY ! AC LIC
DISTANCE MIN 1/2". ANCHOR INSTALLATION LA
,_ . CAULK CL r.
co N N Q
2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO 1X BUCK MASONRY COMBINATION WOOD COMBINATION WOOD
1.50' m
ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. '• ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED)
1—
3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM MIN L_ _0.25" (3) tOx2-1/2' (4 /10x2-t 2 octma=
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT SHIM Wo�D SCREWS NEWS
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE CL—� I_ EACH END OcH ED1111F- 4/9/07
MINIMUM EMBEDMENT OF 1-1/4-. : • SCAMN.T.S.
4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO Moe. sws
TRANSFER LOADS TO STRUCTURE. • • •• c„K 8,.:
TYPICAL WOOD BUCK
5. 0RA1"N0 NG.:
MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ANCHOR INSTALLATION INTEGRAL WOOD INTEGRAL WW DWG-MA-FLO170-07
MULLION (CHS) MULLION (CHS) sim 3