Loading...
HomeMy WebLinkAboutProduct Approval shingles r U � d Liit�4t�t� 1 r Pre; SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FSC Staff BCIS Site Map Links Search drFlorida �p Product Approval TM ,.prw USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved -KECENtb -`--- Comments APR 2 5 2018 Archived ST, Lucie County, permitting Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancr-ant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pi app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boOT%2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 1/2 TRINITY ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sectionscif the 61h Edition (2017) Florida Building Code and Florida Building Code, Residential.Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gqtfty Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shinales: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration0, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color Collection, Tru Definition®Oakridge'l Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip& Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgelm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 CerbTicate afAuthorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ER® 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„it= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6_1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with OBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. ➢ WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshir6l shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment %/ Deck Feltunderlayment '¢ Deck Self-adhered .. Weatherlockv Self-adhered underlaymeni WeatherLocke (� underlayment i Drip_ Drip edge Drip— Drip edge edge edge Nails located Nails located 2-3"from eave 2"-3*from eave Install first Self-sealing adhesive InsSe f-sealing adhesive iG with Starter Strip positioned along eave wt firem oStrip Plus positioned along eave shingle with w °remved removed 6"removed Starter Strip shingle overhangs eaves and rakes rie"-?ri' Stertor Strip Phu overhangs eaves and rakes 1/41-3W Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate afAuthorizarion#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITYERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pare Normal Mansard or Area para Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y Area para vientos normales Areas vientos fuertes Area pare vientos nonnales Areas vientos fuerte.9 1.. 1" r2. 7" 91" 17° 121 12T 5"Exposure 5 5/8e Exposure Exposici6n Exposition 6.2.7 Minimum Nailing—Berkshire®: Sealant strip Sealant strip La t1ra de setlador /(a tirade sellador 8 Yz" 9 8th 11P9 Yt' 8Yt 8 Yz" 8 1h" " 8 W" 1 e a Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip La lira de seilador 8th" T" 0 a dg.. 2 Asphalt rooting cement Cemento de techode astafto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 iTRIM TY. ERCP 6.2.8 Minimum Nailing—Devonshire'"": �8 , 7" 1 8 Nall clavus law Nails V 7' exposure Exposici6n de 5.518 pulg Sealant location Ubleaci6n del sellador Ten 1"Spots of Asphalt Roof Cement Standard 6-Nall Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition" 0 Duration Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern SureNall0f.Steningarea mdth SureNal[O fastening area width Nail,7YP!Cal Nall Typical 12" Tj 12" r Standard Fastening Pattern 6-Nall Fastening Pattern Fastening for Slopes Greater Than 21:12 SUMNOj)FastonIng area width U.N.Typlal '�Pj12" 12" 64ta. 51V Four V Spots of Asphalt Rooting Cement Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 Certificate of Authorization 09503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 .. ._:r' TR1NPY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshireo Hip and Ridge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of Duraffidgel Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 --------HT Fig.2 <__P=TfogWrld 1, Top View SideView Dire lot) Nails Nails Nails 1 2" ttinat I i.. Z• Top LaPiece r 01-T v IV 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.0 Hip&Ridge Shingle Fastening Fig.A 4 4 Toill/low pmall1mvittid 41 1, Z—\\ Nails Nails Nails �2 zInN7 V s. Exposure Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ER® 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11„ ` Wind DirectionFastening `® Sealant Strip Pattern �~� 8`Exposure 1-�2v •� -'I I I. s I I I' - v 12' I Sealant Fasten 711,” 71h.1i'. 7"."osure Cover Exposed li Fasteners with Roof Cement 1---12 6.3.6 Minimum Nailing—DuraRidge'"r Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pra.aiingWrd Diroederl Top Vi" °"—Dira cion dxninmta ds rGnt Yue en pl.m Dirardandalvirnmprodrnimnte HI1" Vista supetlor 1-IH 2 rlo" G— a • Otrcns Cornirog SureF,ail• Nye --� -y--- IRF, � ala• arx�s�l tail V 12'� 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8