HomeMy WebLinkAboutProduct Approval Fbft Bulding Code OnUm :-: RECEIVED Page Iof2
ing
usiness & Professional Regulation
BQS Ilatlle L09 In USM ReOstrMlin Mot Topks i Submit Surduarge Rats&Faccs Publications FBC Statt BOS Site Map Units $larch
dbProductpr Approval
i
U
SER:Public user
ProduC1 AVO—al Menu>Product or Application Seardt>Application list>Application Detail
FL# FL18355-114
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Small PO Box 1404
Joplin,MO 64602
(417)624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
q ..
kerri_eden@tamko.com
' Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
V Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2016
ASTM D 3462 2010
ASTMD D 7158 2011
TAS 100 1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL18355 R4 Eouiv UL letter for standards for FBC 2017 odf
Sections from the Code
https:/lfloddabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKzDl M2Xu9wuWmY6PQIJ... 12/19/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/27/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL tt Model,Number or Name Description
18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage,Heritage Premium,
Heritage Woodgate,Heritage
Vintage,Hip and Ridge,and
Vintage Hip and Ridge Shingles
Limits of Use IestallatWn Imtructions
Approved for use in HVHZ:Yes FL18355 R4 II TBP15001 4 2017 FBC Eval Report Shingles
Approved for use outside HVHZ:Yesnfi ai.Ddf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
other:See evaluation report for limits of use. Evaluation Reports
FL18355 R-) "15001 4 2017 FBC Eval Report
Shingles finai.oU!
Created by Independent Third Party:Yes
flack Neat
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone 850487-1824
The State of Florida is an AA/EEO employerrgu right 007-2013 State of Florida ::Privacy Statement::Accessibility M,State ::Refund Statement
Under Florida law,email addresses are public records.It you do not want your e-mail address released in response to a public records request,do not send
electronic mall to MIs entity.Itn[ead,contactMe office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F. must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
chapter 455,F.S.,please dick DSM-.
Product Approval Accept:
ME ff]"WE EE
Credit Card
Sate
https.//floddabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKzDl M2Xu9wuWmY6PQIJ... 12/19/2017
CREEK Certificate of Authorization No.29824
17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017
220 West 4" Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161 2016
UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2011
UL LLC(TST9628) 06NK03898 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 08CA59132 ASTM D 3161 2016
UL LLC(TST9628) 09NK07896 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) IOCA50498 ASTM D 3462 2010A
UL LLC(TST9628) 10CA64882 ASTM D 3161 2016
UL LLC(TST9628) 11 NK14014 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 12CA24551 ASTM D 3161 2016
UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161 2016
UL LLC(TST9628) 4787148748 ASTM D 7158 2011
ASTM D 3161 2016
ASTM D 3462 2010A
CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017
TBP15001.4 FL18355-R4 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
j
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass-Seal@ 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage-9 Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced.
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Vintage@ 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas& Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage@ Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
R .� TAMKO BUILDING PRODUCTS
�, 1 1 E Asphalt Shingles
!-, TECHNICAL SERVICES. LLC
INSTALLATION
Elite Glass-Seal® Basic Wind Speed(Vint): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(Va,d): Max. 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements,
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction; Min. 15/32 in. plywood existing
(Frederick, Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAILS
Aare ----- -
5-1/8"
Butt Edge
Figure 1. Elite Glass-Seal&Glass-Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
1"
Nailing - ...---r 1----------------------.-- s-7/8,
Area ....--------------- - -- - ... - .....--
5-1/8"
ti
Butt Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
GREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Heritage@ Basic Wind Speed(Vdt): Max. 194 mph
(Dallas, Frederick,Joplin, Basic Wind Speed(Vasa): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
HeritageO Premium new construction; Min. 15/32 in. plywood existing
(Dallas. Frederick construction.
Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage@ Woodgate new construction; Min. 7/16 in.OSB existing construction.
(Dallas& Frederick) Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
FASTENERS NAIL ZON E
COMMON
BOND
6-1/8" FEXPOSURE 5-6/8"
12-1/2"-►�- 12-3/8" -+- 12-1/2"--►I �--1"
Figure 3. Heritage@, Heritage@ Premium,and Heritage®Woodgate(Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS NAIL ZONE
COMMON
BOND
6-11
ce EXPOSURE 5-5/8"
1"—►I J*- -1/2'L�07-1/2"-+- 7-&8"*�7-1/2"-*f*-7-1/2"►1 �_1"
Figure 4. Heritage®& Heritage®Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
NAIL ZONE/
ASTENERSffp —N4 COMMON BOND
T
&-1/8" EXPOSURE 5 5/8"
1� �7-1/2''-7-1/2'+7 /8'+7-1/2+7-1/2&11� �1"
Figure 5. Heritage@ Woodgate
6 Nail Pattern
X! 12-1/2
1
Q Common Bond
" FASTENERS
! T
1 ?�o�
'nO
�W i
39-3/8"
Figure 6. Heritage@, Heritage@ Premium, & Heritage@ Woodgate
Alternate 6 Nail Pattern
PAINT
LINE,,
7-7/8" ---- ___—— ----- - -------- — — --—-NAI L ZONE
6-1/8" EDGE OF
COMMON
BOND
EXPOSURE
5-5/8"
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
----------------- ---------- COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage@(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4,and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.