HomeMy WebLinkAboutProduct Approval (4) Business ♦ ProfessionalRegulation
A= r
BCIS Home ; Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications I FSC Staff ! SCIS Site Map ( Links Search
o ---- -
Product Approval RECEIVED
b
ra
USER:Public Us
Product Approval Menu>Product or Application Search>Application List>Applleatlpp Detail APR 3 0 2018
FL# FL11480-R11 ST. Lucie County, Permitting
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑ o
Product Manufacturer Solatube International,
Address/Phone/Email 2210 Oak Ridge Way
LE C00'
Vista,CA 92081
(760)597-4427
tanderson@solatube.com
Authorized Signature Todd Anderson
tanderson@solatube.com
Technical Representative Todd Anderson
Address/Phone/Email 2210 Oak Ridge Way
Vista,CA 92081
(760)597-4427
tanderson@solatube.com
Quality Assurance Representative
Add ress/Phone/Ema II
Category Sky Lights
Subcategory Skylight
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
t_i Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.Amoruso,P.E.
the Evaluation Report
Florida License PE-49752
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/25/2022
Validated By Steven M.Urich,PE
❑ Validation Checklist-Hardcopy Received
Certificate of Independence FL11480 RI1 COI CI 417-0905 SolatubeSkvliahts ss.odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996-2012a 2012
ASTM E283 2004
ASTM E330 2002
ASTM E331-00(2009) 2009
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL11480 R11 Eauiv EER 1971 Rev5 417-0905 SOLA0004-
SOLA0013 ss.odf
FL11480 RI1 Eauiv EER 1973 Rev4 SOLA0005 ss.Ddf
FL11480 R11 Eouiv EER 2167 Rev4 SOLA0008 ss.odf
FL11480 R1I Equiv EER 2396 Rev2 M74 DS Curb Mount Open.
Ceillna ss.Ddf
FL11480 Rll Eauiv EER 2397 Rev2 M74 DS Curb Mount with
Amplifier ss.Ddf
FL11480 RI1 Eauiv EER 2399 Rev2 Solatube 160 290 DS TDD ss Ddf
FL11480 RII Eauiv EER 2400 Rev2 Solatube 330DS 750 DS
TDD ss.Ddf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/07/2018
Date Validated 02/07/2018
Date Pending FBC Approval 02/15/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
11480.1 160 DS TDD Impact 160 DS(10")Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 RSI II SOLA0004 RevE 160DS-29ODS ss.Ddf
Approved for use outside HVHZ:Yes Verified By: Robert].Amoruso,P.E.FL License No.49752
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+70/-70 Evaluation Reports
Other: FL11480 R11 AE PER 1971 RevS 417-0905 SOLA0004-
SOL60013 ss.odf
Created by Independent Third Party:Yes
11480.2 160 DS TDD Non-Impact 160 DS(10")Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11480 R11 II Model 160 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Packaae.Ddf
Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752
Design Pressure:+70/-70 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2399 Rev2 Solatube 160 DS-290
DS TDD ss.Ddf
Created by Independent Third Party:Yes
11480.3 290 DS TDD Non-Impact 290 DS(14')Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11480 RI II Model 290 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Packaae.Ddf
Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752
Design Pressure:+70/-70 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 RIJ AE PER 2399 Rev2 Solatube 160 DS-290
DS TDD ss.Ddf
Created by Independent Third Party:Yes
11480.4 290 DS TDD Impact 290 DS(147 Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II SOLA0004 RevE 160DS-29ODS ss.Ddf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+70/-70 Evaluation Reports
Other: FL11480 RI1 AE PER 1971 RevS 417-0905 SOLA0004-
soLA0013 ss.Ddf
Created by Independent Third Party: Yes
11480.5 300 DS TDD Impact 300 DS(14')Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II 30Q DS SKYLIGHT-MAN iFACT RERS
Approved for use outside HVHZ:Yes INSTALLATION DETAIL PA KAGE.odf
Impact Resistant:Yes FL11480 R11 II SO A0013 Revn 30ODS sqndf
Design Pressure: +70/-70 Verified By: Robert J.Amoruso,PE FL PE No.49752
Other: Created by Independent Third Party:Yes
Evaluation Reports
EL11480 R11 AE PER 1971 Revs 417-0905 O A00n6-
SOLA0013 ss.odf
Created by Independent Third Party:Yes
11480.6 330 DS TDD Non-Impact 330 DS(2 1 )Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL31480 RS1 II Model 330 DS TDD-Prod in Drawing
Approved for use outside HVHZ:Yes Packaue.pdf
Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752
Design Pressure:+70/-70 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2400 Rev2 Snlatuhe 33 DS 750 DS
TDD ss.Ddf
Created by Independent Third Party:Yes
11480.7 750 DS TDD Non-impact 750 DS(21')Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11480 Rif II Model 750 DS TDD-Prod ict Draw
Approved for use outside HVHZ:Yes Packaae.ndf
Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752
Design Pressure: +70/-70 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2600 Rove Solatube 33nnc 750 nc
TDD ss.pdf
Created by Independent Third Party:Yes
11480.8 750 DS TDD Impact 750 DS(21')Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL114B0 R11 II SOLA0005 RevD 750DS odf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: +70/-70 Evaluation Reports
Other: FL11480 R11 AE PER 1973 R v4 SO A0005 ss.odf
Created by Independent Third Party:Yes
11480.9 Smart LED Smart LED 10"Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 Ril II SOLA0008 RevC ss odf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E.49752
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: +70/-70 Evaluation Reports
Other: FL11480 R11 AE PER 2167 R v4 SOLA0008 cc ndf
Created by Independent Third Party:Yes
11480.10 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD-Dual
Ceiling TDD Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R31 11 M74 DS-O-DPP-FC-B-L2-REG FBC-
Approved for use outside HVHZ:Yes PER2396 ss.Ddf
Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752
Design Pressure: +80/-80 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2396 Rev2 M74 DS Curb Mount
Open Ceiling ss.Ddf
Created by Independent Third Party:Yes
11480.11 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD-Single
Ceiling TDD Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II M74 DS O-DP-FC B-L2-REG FBC-
Approved for use outside HVHZ:Yes PER2396 ss.odf
Impact Resistant,Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752
Design Pressure:+80/-80 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2396 Rev2 M74 DS Curb Mount
Open Ceiling ss odf
Created by Independent Third Party:Yes
11480.12
Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with
Ceiling TDD with Amplifier Amplifier-Dual Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 1111 11 M74 -DPP-F - - 2-RE F8C-
Approved for use outside HVHZ:Yes PER2397 ss.0df
Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E.FL PE No.49752
Design Pressure:+80/-80 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2397 Rev2 M74 DS Curb Mount
with Amplifier ss.pdf
Created by Independent Third Party: Yes
11480.13 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with
Ceiling TDD with Amplifier Amplifier-Single Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-0-DP-FC-A-L2-REG FBC-
Approved for use outside HVHZ:Yes PER2397 ss.Ddf
Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E.FL PE No.49752
Design Pressure: +80/ 80 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2397 Rev2 M74 DS Curb Mount
with Amplifier ss.Ddf
Created by Independent Third Party:Yes
Back Ne:t
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an.email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
= Wwgigm
Credit Card
Safe
� q N • V N
� . y 1
gp
Z l X $ A o O A�} m=�N
s Z a n
1A
3 ifln
01
" gee A' � e y
m m T > "oHEW 95
3 Q
NQ U "y'QNO O 2N po Ory yiy A
O (�5 9ZZ;tltlA�zbg <H< O �� ILLm*+111�� 3 mZZ O u
4O Him H ACG-1�-
mo -.PH 1b i� I A����
HUI
°P $c ��°F = $ aa8g� TTCCAw
�51ny yy ZfAl
to m ��"
��$ cis � `�
r amp y NOW �9 g; I
� n A o$���
m a n
3,6 SOLATUBE INTERNATIONAL 417-0603
AUPDATE DMY/k!6 F911
2210 OAK F.mO&BAY
VISTA, CA 92081-9941 Jv M TD 5rn
3 ' m IMPACT 160 DS (10") h 290 DS (14") D S/11/15 JBN
(=n�Y?ii TUBULAR DAYLIGHT DEVICE a RtED°�"n0N5 oVso/1s.+m+
94 n S �P-�-nurx m. B ES
GENE AN RMSED AMCRORADE 4/14/15 0.0
u ,% s'•:E;,,,,,;, SMC ��10 OB D8
UPDATE w 3010
a
N.T.S. SOLA0004 Pec to/1 s/
11 tax
E 1 OF 6
A
n a a C e
:1
1. STI—RAL E:EW FN2(rlY oO RAE21s,DX I""c) At
PA
i R ]� 61 o-Ist SHOWNf01 lf3EifMCE O,,Y lSElrM:f O Al�EINAiED17NslSE-1 IIRAIIONSR1:IfC1ANGU'.AI FOAM 01 SEA4NfFLASHING SHOWN WITH OPTIONAL2"-48'TALL TURRET EXTENSION C d oo �
_= z o
11.0 17 le ]e 19 22 i o o
DETAIL B -< Nw r
E
R73.8 t 5ii No vi
TUBEw
U ■g
11 ]w 26
Lx 12 41.1
]e ]
1] ]7 7 4
E- `~ �$�
o.
t �
_ 99
SECTION A-A y $
.:t
.r s�masa-s•
RoSerl J.Amqusp,P.E.
•'W /� FL P.F..ND.49757
lo
e "w DETAIL
{-- Digitally signed by
Robert J Amoruso
ate:2017.10.19
16:04:36-04'00'
290 DS (14") FLASHING OPTIONS
015.9 TOP OF FLASHING • e
v R R
R
61 TOP Of FLASHING 15.9 23.3
6.1 8.7 iF
18.0
9.2 6.0 18.0 <
m �
0
�-
o � o
o� n
E g a
23.3 8.7 O d>•v v
Z m �z
R-
PITCHED FLAT 6" a N n
z�U� cFl�
a
8X FLASHING FASTENERS N 5 Tm fF!
rte- c
T
FLASHING FASTENER SPACING (~ a FLAT P,FLAT 6"i FRCHEDOkillY
015.9 FLASHNG
TOP or i
015.9 TOP OF
gL
HING
B%FLASHING FASTENERS, 6.1
2X FASTEN9S PEA SIDE
-
• - - 2.0 4A
_ 18.0
0
ROEeM1 J.M�auo,P.E
A.P.E.No.49M
Digitally signed by
FLAT 4" CURB RobertJ Amoruso
Date:2017.10.19
16:04:24-04'00'
4 n
160 DS (10") FLASHING OPTIONS o a a
m .
011.9
011.9 TOP Of FLASHING v p R
77
2
TOP OF FLASHING
5.0 -
5.0
• 6.0 8X FLASHING FASTENERS
7.4 16.6
20.0 d m ~ m
8.1 z o 0
O o
1
E-+ oU a
FLAT 6' Zip W
Q~ z
z
PITCHED 20D 8.1 O
z Ft
H
�
E-
FLASHING FASTENER SPACING �Y
FLAT 4",FLAT 6"8 PITCHED o
U @
011.9 70P OF BASHING
011.9 TOP OF FLASHING
0 4.0 - pp 4.0
14.8 16.6
RcbeA J.Amoroso.P.E
FL P.E.N.49752
�i�1'ry•�)�.jjj
^�J9/
8X FLASHING FASTENERS,
FLAT 4" 2X FASTENERS PER SIDE Digitally signed by
CURB Robert J Amoruso
Date:2017.10.19
16-04:09-04'00'
a
160 DS (10") AND 290 DS (14") 290 DS (14") DECORATIVE a a
DECORATIVE FIXTURE OPTIONS FIXTURE OPTIONS
R
E
i 'JUST FROST'DECORATIVE �
FIXTURE ASSEMBLY
'AURORA GLO'DECORATIVE i
FIXTURE ASSEMBLY a
z 4
o o�
� IVO U
F"
71ER DROP'DECORATIVE J / OPTIVEWDECORATIVE Z e�
FIXTURE ASSEMBLYW og
FIXTURE ASSEMBLY e� 6�
-
+c r.aa a.,m.r,eoa.aorarer. ' �D
E- q
aYrOa =mm �
2 ' O
� 9!@
.wrciM m oarY6ar�aaoar oara.aae
arc 000ernar amer
aue me amr naw
a m¢
i
5
O1' �1 , 7
RoberlJ.Anwruw,P.E
�— FL RE No. 99752
m aev euua rma�mruva by
•or ru ac amrr rnor annv srua•'roar eaawow ,�wr:�B
, � rar m on. tea: am�oa ;mw
a r aoMC ar na aar4c 1,�`;�
r
a ras moa mm a a a.aaa mm •��'�°'
Digitally signed by
Robert 1 Amoruso
Date:2017.10.19
16:03:40-04'00'