HomeMy WebLinkAboutdrawing e
Size
Opening
: (WxH)
1 :Accordion Shutter, 74 x 63'' s
�;(Side-Windoiv)
2 :Qccortliori Shutter 74 x 39 ,
(Side'Window)
3. Accordion Shutter 37 09
(Back,Window)
4. AccordiomShutter 74x3.9
(Back Window)
4 3
f
F, s
F:
3
1
m
C cIL
d `nm
N cCU .
YZI
..
U)
a
s
C0PYRIONTE•ItMPE9T.00N
SCALE:
Vl+'�r r iA NOT TO SCALE
p DATE:
o ® May 02,2018
OPAGE DESCRIPTION:
C r v Site Plan
�' PAGE: OF1
K N
T
1
Property Information Building Information
Owner: Olsen Wind Zone: 160 MPH.
Address: 17 Lake Vista Trail Exposure Category: B
101 Minimum Building Dimension: 24 ft.
Port St Lucie,F134952 Mean Roof Height: 20 ft.
JR Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) JIHeight(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 74 63 7 27.5 -30.0
--............_..__._._ .._.... -- -...__...._......._... .__.....
_ _._......_._.__._.. _._..
2 Int 74 39 7 28.4 -30.9
_._...-- —......---
...._......-.......
3 Int 37 397 29.7 -32.2
............. ....-...-......._....._ _..._...._--------._.......----.............._.. __.._..................
..._...
_
4 Int 74 39 7 28.4 -30.9
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1