Loading...
HomeMy WebLinkAboutProduct Approval (2)Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema. ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext 3327 memathieu @soprema . ca Quality Assurance Representative Jean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CI Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich, PE G Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN odf fig.:.... Business & Professional . ASTM D1970 2015 ASTM D4798 2011 SCIS Home i Lag In I User Registration Hot Topic; Submit Surcharge Stats & Facts Publications FBC Staff i BCIS Slte Map Links Search FM 4474 Florida Product Approval FRSAfrRI April 2012 (04-12) 2012 dL"% .rj USER; Public User i.'.•.c: .:s": h'.Stp� Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL2569-R14 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema. ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext 3327 memathieu @soprema . ca Quality Assurance Representative Jean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CI Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich, PE G Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN odf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSAfrRI April 2012 (04-12) 2012 UL 1897 2012 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2018 Date Validated 02/14/2018 Date Pending FBC Approval 02/17/2018 Date Approved 04/10/2018 Summary of rodacts FL # Model, Number or Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Approved for use in HVHZ: No Installation Instructions FL2569 R14 II 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- R14,Dd_f Verified By: Robert Nieminen, P.E. PE -59166 Approved for use outside HVHZ: Yes Impact.Resistant: N/A Design Pressure: +N/A/ -150 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure Evaluation Reports FL2569 R14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- R14.pd noted herein pertains to underlayment systems used beneath adhesive -set tile Created by Independent Third Party: Yes systems. Refer to ER Section 5.6.4 for details. Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 950-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Und r Florida law, email addresses are public records. if you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval AA�ccceepts: WN Is Credit Card Safe NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Soprema, Inc. Evaluation Report S18010.06.09-1112 1640 rue Haggerty 1`12569-1114 Drummondville, Qu6bec J2C 5P8 Canada Date of Issuance: 06/15/2009 (819) 478-2400 Revision 12:02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO Ietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEM01etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4 ANE1983 CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. The facsimile seal appearing was authorized by Robert r''. Fs; ••••�••••�? �• Nieminen, P.E. on 02/12/2018. This does not serve as an .:'��+.�•,��•�«`''�• electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: SCOPE:1. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: intpl Examination Reference Date ERD (TST6049) ASTM D1970 / TAS 110 2968.05.04-2 05/14/2004 ERD (TST6049) Physical Properties 2757.02.05 02/03/2005 ERD (TST6049) ASTM D1970 / TAS 110 2974.03.05-2 05/17/2005 ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD (TST6049) TAS 103 / TAS 110 57120.11.07-2 11/02/2007 ERD (TST6049) ASTM D1970 / TAS 110 S13190.02.09 -R1 04/01/2010 ERD (TST6049) ASTM D1970 / TAS 110 531370.03.10-1-R1 04/07/2010 ERD (TST6049) Physical Properties / Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD (TST6049) Physical Properties / Tensile Adhesion 511150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties/ Tensile Adhesion 543530.02.14-1 02/21/2014 ERD (TST6049) Physical Properties/ Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M -D (CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC -ES (EVL2396) 2015 IBC Compliance ESR -1524 03/01/2017 PRI (TST5878) Physical Properties SOP -064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 PRODUCT4. DESCRIPTION: 4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970. 4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. NEMO ETC, LLC Evaluation Report 518010.06.09-1112 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 2 of 8 ONEMO I etc. 4.5 Lastobond Pro HT -N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.6 Lastobond Pro HT -S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.7 EnviroShield is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.8 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.10 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.11 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.12 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36 -inch sheet width; meets ASTM D1970. 4.13 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36 -inch sheet width; meets ASTM D1970. 4.14 RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 44 -inch sheet width; meets ASTM D1970. 4.15 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 5. UmITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Allowable Roof Covers: NEMO ETC, LLC Evaluation Report S18010.06.09-1112 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 3 of 8 ONEMOIetc. 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives/ underlayment combinations. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 518010.06.09-R12 Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 4 of 8 Wood or Slate or Underlayment Asphalt Nail -On Foam -On Metal Composite Composite Shingles Tile Tile Shakes& Slate Shingles Lastobond Eaves Protection Sheet/ Yes No No No .' Yes Yes Lastobond 195 Lastobond ECO / RESISTO LB1236, Grip -Rite Eave & Valley Protector / Yes No No No '; Yes Yes RESISTO LB1244 Lastobond Smooth Seal HT Yes No >No Yes Yes Yes Colphene FR GR Yes Yes Yes See 5.5.1 No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives/ underlayment combinations. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 518010.06.09-R12 Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 4 of 8 ONEMO I etc. 5.6.3 Bond to Mechanically Attached Base Layer: Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having 5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report 518010.06.09-R12 Certificate ofAuthorization 1132455 CH EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12:02/12/2018 Page 5 of 8 Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #3 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32 -inch APA -rated BCX plywood (may be installed C -side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end - laps. #4 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6 -inch o.c. at the 4 -inch laps and 6 -inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered 5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report 518010.06.09-R12 Certificate ofAuthorization 1132455 CH EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12:02/12/2018 Page 5 of 8 ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30 -days after installation. Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT- S, EnviroShield shall not be left exposed for longer than 90 -days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180 -days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10 -tile stack 6:12 Lugged Max. 10 -tile stack 5:12 Max. 10 -tile stack (bottom 2 -tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT Lugged Max. 10 -tile stack 5:12 Flat Colphene FR GR Lugged Max. 10 -tile stack 6:12 NEMO ETC, LLC Evaluation Report 518010.06.09-1112 Certificate ofAuthorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1114 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 6 of 8 ONEMOletc. 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT; Lastobond Pro HT -S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, RESISTO 1.61236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Colphene FIR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6 -inches and staggered not less than 2 -ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. . When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the sheet at 12 -inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and Soprema published requirements for tile staging. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. NEMO ETC, LLC Evaluation Report 518010.06.09-1112 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1114 Soprema Roof Underlayments Revision 12:02/12/2018 Page 7 of 8 ONEMO I etc. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product(s) Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT -N, Lastobond Pro HT -S, EnviroShield, Lastobond 195, Drummondville, ASTM D1970 Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth QC (Canada) Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/TRI 04-12 Colphene FR GR Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, Wadsworth, OH ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/TRI 04-12 Lastobond TU HT; Colphene FR GR Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, Gulfport, MS ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 QUALITY9. UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com NEMO ETC, LLC Certificate of Authorization #32455 - END OF EVALUATION REPORT - 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Soprema Roof Underlayments Evaluation Report S18010.06.09-1112 FL2569-R14 Revision 12:02/12/2018 Page 8 of 8