HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10674 R13 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2016
2010
2011
https:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT... 2/7/2018
BCIS Home Log In I User Registration Hot Topics 'II
Submit Surcharge Stats & Facts
Publications ; FBC Staff
BCIS Site Map Links Search
Florida
_
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application
List > Application Detail
///►►►
-
FL #
FL10674 R13
Application Type
Code Version
Revision
2017
v
�� ,
Application Status
Approved
IT
V
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10674 R13 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2016
2010
2011
https:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT... 2/7/2018
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
10/10/2017
10/11/2017
10/15/2017
12/12/2017
Page 2 of 2
FL # Model, Number or Name
Description
10674.1 Owens Corning Asphalt Roofing
3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.ndf
Created by Independent Third Party: Yes
Oack FN 7- t
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 650.467.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
httns:Hfloridabuildina.org/Dr/Dr ann dtl.asnx?naram=wGEVXOwtDatBNbEY5V%2boOT... 2/7/2018
Q0TR1N1*ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 037940.02.12-R8
FL10674-1113
Date of Issuance: 02/06/2012
Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
,��rnrr„•
LU
Robert J.M. Nieminen, P.E.
Florida Registration No. 59165, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
\l l RINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161
2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158
2011
3. REFERENCES:
Entity Examination Reference
Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453
05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263
04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308
02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137
02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532
02/10/2014
UL LLC (TST9628) Physical Properties Classification letter
02/13/2014
UL LLC (TST9628) Physical Properties Classification letter
10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs
Various
UL LLC (QUA9625) Quality Control Service Confirmation
Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supremem are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire® are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 DevonshireTm are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition®
Duration® Designer Color
Collection, TruDefinition® Oakridge®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles,
ProEdge Hip & Ridge
Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge
asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization 119503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 8
TRINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vaed = 150 mph (Vt,lt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa = 150 mph (V„It = 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 611320-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuarde HP shingles require minimum six (6) nails per shingle.
➢ Devonshire•" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt underlayment
Deck
f
Self -adhered
i Weatheri-ocke
underlayment
Drip_
Drip edge
edge
Nails located
2"-3" from eave
Install first
Self-sealing adhesive
Starter Strip
positioned along eave
shingle with \
6" removed
Starter Strip shingle overhangs eaves and rakes %"-3/4"
Felt underlaymentDeck Sel!Wdhered
t Weathed-ock�
underlayment
Drip Drip edge
edge
Nail located
2"-3"from save
Instal first Starter StripPlus Sal sealing adhesive
with 6" removed positioned along eave
' \
Starter Strip Plus overhangs eaves and rakes 1/4"-3/4"
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1313
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 3 of 8
6.2.6 Minimum Nailing — Classic®& Supreme:
Normal Mansard or Aro. para
Wind Areas High Wind desvanes y
Area pore vientos normales Areas vientos fuertes
61,
1t• 1r
V'Exposure
Exposici6n
6.2.7 Minimum Nailing — Berkshire®:
Standard Fastening Pattern
�PTRINI*ERD
Normal Mansard or Aran pare
Wind Areas High Wind desvenes y
Area para vientos normales Areas vientos fuertes
�•
121 121
5 51W Exposure
Exposici6n
Sealant strip
La tira de sellador
6 -Nail Fastening Pattern
Sealant strip
La tlra de sellador
e! ►
04 ---------- 0. e a e4 ----------- ) e
R r/i' R'/t' R 11f
Z Asphah roofing cement
Cemeato de techo de astaho
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 4of8
s Vile
8 rh,�
1 112.".7"
r
r
6 -Nail Fastening Pattern
Sealant strip
La tlra de sellador
e! ►
04 ---------- 0. e a e4 ----------- ) e
R r/i' R'/t' R 11f
Z Asphah roofing cement
Cemeato de techo de astaho
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 4of8
6.2.8 Minimum Nailing— Devonshire'":
7" l rl
•
Nal
claws
5-5/8" exposure Sealant location
Exposicion de 5 -5/8 pulg Ubiracion del sellador
Standard 6 -Nail Fastening Pattern
�I TRINITY ERD
Nails
Ten 1" Spots of Asphalt Roof Cement tII
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & TruDefinition®
Duration• Designer Color Collection:
4 -Nall Fastening Pattern
sumNalm tasnning area width
Nall, Typlml
1:l 12" i
r"118
ED F] I
Standard Fastening Pattern
6 -Nall Fastening Pattern
SunNall>D fastening — width
Nall, Typical
1" 12' I 12" t"
•w.mcwyrvw..v
F1feE5-5tV F�
6 -Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
Sur,N,Iw r,—ning •r.. width
Nell, Typlul
1"I 12" 12" 1'
r � i
ave" s ve
Four 1Sp.. of Aaphall Rooting Cement
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12 -RS
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 5 of 8
6.2.1 Minimum Nailing — TruDefinition Oakridge®, Oakridge®:
4 Nail Pattern
Fsquema con 4 clavos
5 5/8" Exposure Nails 5 5/8" Exposure
Fxposid6nde6619pu1g. Clams Fxposici6nde6656/8pulg.
Standard Fastening Pattern
�I TRINITY ERD
6 Nail Pattem
Fsquema con 6 clavos
1. 1..
It— ,z- —3►{ f f— �2 —�►I
5 5/8" Exposure clavas 5 5/8" Exposure
Erposlcion de 5 618 pulg. Exposicion de 6 5/8 pulg.
Fastening for Slopes Greater Than 21:12
1r S—ii, J faafanlnp ma rrldlh
I FNail, Typi-1
12- I 11"
Four 1' Spob of Asphax Routing Camanl
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuard® HP:
6 -Nail Fastening Pattern
@—f2"I
' • "Y1r ' single
t• AN& lrbid
Ir— 7 =r1
-7�
F..wnr7l�w+� wl Lirr
10boW ads... -M=
Exterior Research and Design, LLC. Evaluation Report 037940.02.12 -RS
Certificate ofAuthori:ation #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 6 of 8
VT_R`INI*ERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig. 2
T.plfi w Sld'View
Nals if
Nails
z"
Z Top Larninalrzl I
4" Piece
I
I
I
I
ul
�I
a^ �l
�I
VI
I
I `SII
'Z- I
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig. A q 4
PmvallIng Wind
Dftdlbn A
A
Nal Is
A �\ A
I I
I I I
A\ I I I I
p \l I I I
I I I I
S' I
Ezposum
Fig. C Hip & Ridge Shingle Fastening
Top ftvi
Nails Nails
T'
S' Exposure
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
A---- 6" Exposure
Fasten 711a'
Cover Exposed
Fasteners with
Roof Cement
�l TRINITY ERD
Standard
Fastening
Pattern
72'1 I=E.p
Sealant
77 i
6.3.6 Minimum Nailing — DuraRidge'" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Preraifng Wind Directim
{— Dimaiondrnimntadjv t
DiracdCn del vienta prodornitante
- T -
Nails .- - - -- s—
Clo c I
arot� I I
H I I
I I
0-
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@uI.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 8 of 8
TIP View
H
I
Ween plan
yl...superior I- q
T
2 t/i
Owona Cotdrta SurcNall'
I
I
I�
"lo €
ala$
� IJ„ic
I
If
12- 'I
0-
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@uI.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 8 of 8