HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online Page 1 of 3 Professional -gs SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links _I Search b' ar `' RECEIVED ' �=` Product Approval USER:Public User Protluct Approval Menu>Product or Aoolication Search>Application List>Application Detail MAY 072018 FL# FL22513 R2 5T. Lucie County, Permitting Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@qpmic Authorized Signature Steve Schrei r E C011- v1 sschreiber@ soni Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 04/16/2018 Date Validated 04/18/2018 Date Pending FBC Approval Date Approved 04/24/2018 https://www.floridabui lding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgtdytNblepz46Q... 5/7/2018 Florida Building Code Online Page 2 of 3 t Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747 01-Rl.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 11 FL0212,pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R2 AE 514008 ocif system is required. Door top rails stamped"HPC". See DWG- Created by Independent Third Party:Yes MA-FL0212 for details. 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.04.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other:Evaluated for use in locations adhering to the FL22513 R2 II FL0215 Ddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed.3'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R2 AE 514009.Ddf system not required. See DWG-MA-FLO215 for details. Created by Independent Third Party: Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2...0 CAC N1013747 04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0215.udf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective F1 22513 R2 AE 514007.odf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed Sidelites. See DWG-MA-FLO215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747 04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0215.0f Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R2 AE 514007.odf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed sidelites.See DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.06.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0217 Ddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 R2 AE 514007 udf system is required. See DWG-MA-FL0217 for details. Created by Independent Third Party: Yes 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single Door Unit https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46Q... 5/7/2018 Florida Building Code Online Page 3 of 3 Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C GAC N1013747-R1.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0211.0f Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed.3'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective F122513 R2 AE 514010 odf system not required. See DWG-MA-FL0211 for details. Created by Independent Third Party: Yes 22513.7 Wood edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C__.._ 'j_1;; �2,..l.udf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0211.L)jr Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R2 AE 514008.uclf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed sidelites. See DWG-MA-FL0211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC N1013747.03-Rl.udf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 R2 II FL0214.Dddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 R2 AE 514008 Ddf system is required. See DWG-MA-FL0214 for details. Created by Independent Third Party: Yes Back Neat Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone•850-487-1824 The State of Florida is an AA/EEO employer.('novriaht 2007-2013 State of Florida.::Privacy Sta_temennt::Ac-11,hrlity S a[ nt::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here-. Product Approval Accepts: ROME IM E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46Q... 5/7/2018 NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: NI013747-R1 1955 Powis Road Certification Date: 06/08/2017 West Chicago,IL 60185 Expiration Date: 06/30/2021 Revision Date: 04/13/2018 Product: Wood-Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites (w/Wood Frame unless noted) Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non-Impact Glazing: Insulating Glass(Tempered) The"Notice of Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listin at www.Namicertification.com. NAMI's Certification Pro ram is accredited by The American National Standards Institute(ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& OutswinR Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0"x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size:3'0"x 618" Anchor Details-DWG-MA-FL0211-17 X O/S Opaque 3'0"x 6'8" +70/-70 3.0 psfl Yes ATLNC 1001.01-13/W-1857 Single psf' MaximuAnchor Deo is DWG MA FL021Panel Size:3'0"x 8-17 7.5050 psf,,< XX 1/S Opaque 6'0"x 6'8" +551-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 XX O/S Opaque 6'0"x 6'8" +55/-55 3.0 pst' Yes NCTL-210-2930-1 Double 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50psf' Anchor Details-DW&MA-FL0211-17 XO/OX I/S Opaque Door 6'0"x 6'8" 1-55/-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size:3'0"x 6'8"%Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 XO/OX O/S Opaque Door 6'0"x 6'8" +55/-55 3.0 psfl Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 OXO 1/S Opaque Door 910"x 6'8" +551-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FL0211-17 OXO O,/S Opaque Door 9'0"x 6'8" +551-55 3.0 psfl Door-Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf. Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0'"x 6'8" 7.50psf' AnchorDetails-DWG-MA-FL0211-17 OXXO US Opaque Door 12'4"x 6'8" +551-55 0 psf Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-F1,0211-17 OXXO O/S Opaque Door 12'4"x 6'8" +551-55 3.0 psf Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50psf' I Anchor Details-DWG-MA-F1,0211-17 I-Denotes Bumper Oalswing Threshold 2-Denotes/-Series Outswing Threshold 3-Hi-Dorn Outswing Threshold 4-Pro 74'ritreshold 5-HP Outswing Threshold National Accreditation & Management Institute,Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804)684-5124/Fax: (804)684-5122 NAMI AUTHORIZED SIGNATURE: � A � 111 MASONITC. r` 149"MAX. OVERALL FRAME WIDTH - a - 21 MAX 36.375" MAX. 8 0 p WOOD-EDGE STEEL DOOR UNIT �- D.L.O. PANEL WIDTH- 37.5" MAX. ( rc p 6'-8"DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH �) fYY J ti GEN__ FRdE f NOTES f - ; a 3 O 1. EVALUATED FOR USE IN LOCATIONS ADHERING Q U THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, _ DOES NOT EXCEED THE DESIGN PRESSURES LISTED. j ku In U 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON a^o N Z M� OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELTTES. o -� n 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, Q I uj EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), g HURRICANE PROTECTNE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED �„ z ON PANELS WITH NON-IMPACT GLASS. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: I EST DESCRIPTION DESIGNATION LITE FRAME � } SELF IGNITION TEMP ASTM D7929 842 'F > 650'F RATE OF BURNING ASTM D635 1.28 IN MIN -� e Nco SMOKE DENSITY ASTM D2843 IV 8 y TENSILE STRENGTH- ASTM D636 1. 1.8X DIFF Sl. • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING S 4500 HOURS XENON ARC METHOD 1 DOUBLE DOOR UNIT WfSIDELIT S o 0 a a ® 13 1313 0[3 ® ® ® ® 1313 1311 00 0, n 0' 0 1 U ' i j L L o w *0 L L__j SINGLE DOOR UNIT DOUBLE D04R UNIT a 51C1GLE DOOR UNI SINGLE DOOR UNI ,�rNGLE DOOR UNIT WfSIDELITES DOUBLE DOOR INf7 W✓�10 m c WITH SID£LtTE WITH S(DELITE Ll a 0 WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15X OF DESIGN PRESSURE MAX WI TH IOUTSWING IN WING BUM ER 0 S Z-S RIES HIGH DAM 4 0 S HP BU X 7.5 +70.0 -70.0 + . - N A +20.0 -20.0 +30.0 - + -50.0 +50.0 0.0 XX 74 +55.0 - +55, - .0 N A +20.0 -20.0 +30.0 -30.0 + 0.0 -50.0 N A N a z OX or 0 7 + .0 -55.0 + .0 -55.0 N A +20.0 -2 . + - + 0.0 - 0.0 N A N A I 0X0 11 t5 - + .0 4 -5 .0 N A +20.0 -20.0 +30.0 - .0 +50.0 -50.0 N A N A OXXO 14 + - +55.0 -55.0 N A +2 .0 -20.0 +30.0 - 0. + .0 -50.0 N A N A ATE 5 26 17 Ahkrdun to NO DWG.BY. SINS TABLE OF CONTENTS _ SHEET iT DESCRIPTION ;e Uron tb.: �Ytu ll7h'Zc CHK,Ix: 1 TYPICAL ELEVATIONS 8t GENERAL NOTES KURT BALTHAZOR DRAMING NO.'. 2 ANCHORING LOCATIONS & DETAILS Do I FLORIDA P.E. DWG-MA-FLO211-17 156533 3 ANCHORING LOCATIONS & DETAILS sH117 1 OF