Loading...
HomeMy WebLinkAboutDrawing Opening I ; Size 1 Accordion Shutter. 53 x 55, (Front M7ndow) 2.`Accordion Shutter'`' 26x40 m (Side Window) in 3. Accordion Shutter, '26 x 46 �l (SidelWfndow) CD 4. Accordion Shutter 74 x 55; Q m vCAD rn m (Back Window) o v rn 5:"AccordionShutter '. ,53 x 55'! (Side Wfndow)• .. _ ` q3 6 Accordion.Shutter, 53 x 55 de Window) 4 3 L r ULO c� 0) 'C O M 5 C c6 LL � Q U 2 LO a M U- 6 CCPYMGHT E•TEMPEBT.CCM - A SCALE: 1 NOT TO SCALE WE: May 02,2018 PACE DESCRIPTION: Site Plan PAGE: OF1 1 Property Information Building Information Owner: Reynolds Wind Zone: 150 MPH. Address: 14357 Amapola Cir Exposure Category: B Ft Pierce,F134951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. JR Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 53 55 7 27.2 -29.7 2 Int 26 40 7 28.5 -31.0 --- ---. —._......._... --- ..... – —_ — 3 Int 26 40 7 28.5 -31.0 4_ Int 74 �— 55 7 26.6 -29.0 5 Int 53 55 _ 7 27.2 -29.7 6 _ Int - 53 —�- 55 7 27.2 -29.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1