Property Information Building Information
Owner: Reynolds Wind Zone: 150 MPH.
Address: 14357 Amapola Cir Exposure Category: B
Ft Pierce,F134951 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
JR Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 53 55 7 27.2 -29.7
2 Int 26 40 7 28.5 -31.0
--- ---. —._......._... --- ..... – —_ —
3 Int 26 40 7 28.5 -31.0
4_ Int 74 �— 55 7 26.6 -29.0
5 Int 53 55 _ 7 27.2 -29.7
6 _ Int - 53 —�- 55 7 27.2 -29.7
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.