Loading...
HomeMy WebLinkAboutdrawing/placement Opening Sizes (W ) , 1.,Accordion,Shutter`` 53 x 63, ,:(Front Window) 1-`Accordion Shutterr '- 74 x 63 g `(Back Window) p 3, Accordion Shutter.' 53.x55, (Side Window) m 0 C4 4. Accordion Shutter 53 x 55 °c d o v (Side Window)] 3 OD CD CP C 2 O r3 LOLO 4 �. Z M O � u- O -0 ai M c� tiU- LOPYRIOHT E-TEMPE9T.COM SCALE: NOT TO SCALE . ATE,* May May 02,2018 PAGE DESCRIPTION: Site Plan PAGE: OF1 Property Information Building Information Owner: Woolf Wind Zone: 150 MPH. Address: 7 Villas del Norte Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device JDevice Device Max Positive Max Negative Number Zone Width(in) Height(in) IF 11 Elevation(ft) Pressure(psfj Pressure(psf) 1 End 53 63 7 27.0 -35.1 - --....._...— --.........__.. _-.........._..........---- ................._. _..._.._ .......... ............. - 2 Int 74 63 7 26.4 -28.8 3 Int 53 55 7 27.2 -29.7 --...__..__ _.._.. _............-- -........_............--- ............... ----- 4 Int 53 55 7 27.2 -29.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1