G March 27,2018
Bryanne&Jon Rodriquez
7406 Roberts Rd. Bryanne.rodriquez@gmail.com
Fort Pierce FL,34951 Shingles
i
Dillon Roofing LLC,a Florida licensed contractor(Florida License No.CCC#1331348)proposes to the Owner to
perform in a workmanlike manner the roofing construction work described below under Specifications for the
Owner at the above-referenced building.
1.NATURE OF WORK:Dillon Roofing LLC shall furnish the labor and material necessary to perform the
construction work described herein or in the referenced contract documents.Dillon Roofing LLC does not provide
engineering,consulting or architectural services. It is the Owner's responsibility to retain a licensed architect or
engineer to determine proper design and code compliance.Dillon Roofing LLC assumes no responsibility for
structural integrity or compliance with building codes and design. If plans,specifications or other design
documents have been furnished to Dillon Roofing LLC.Customer warrants that they are sufficient and conform to
all applicable laws and building codes.Dillon Roofing LLC is not responsible for any loss,damage or expense due to
defects in plans or specifications or building code violations unless such damage results form a deviation by Dillon
Roofing LLC from the contract documents: Customer warrants all structures to be in sound condition capable of
withstanding normal activities of roofing construction equipment and operations.
2.CONTRACT PRICE: Dillon Roofing LLC proposed to perform the work in accordance with the above specifications
for the"Cash Price"sum of$12,950.00. If contractor incurs any expenses in collecting money due under this
contract,Owner shall reimburse Contractor for all such expenses,including reasonable attorney's fees. Contractor
is entitled to interest at the rate of 1.5%per month on all amount not paid when due.
3.TERMS AND CONDITIONS: The terms and conditions set forth herein are part of the Proposal and Contract.
4.CONTRACTORS RIGHT TO RESCIND: Contractor reserves the right to withdraw or revise this Proposal until
Owner communicates his acceptance to Contractor. This proposal may be withdrawn after communication of
acceptance where an error by Contractor has occurred. This Proposal expires thirty(30)days after the date stated
above if not earlier accepted,revised or withdrawn.
5.ACCEPTANCE: Acceptance of this Proposal by Owner shall be acceptance of all terms and conditions recited
herein.Upon acceptance,this Proposal shall become a binding contract between Contractor and the Owner. The
Proposal and the plans,specifications and other documents,if any referenced in this proposal shall constitute the
entire agreement between the parties.
Repres tive of Dillon Roofing LLC. Accg ted By
pp ,
Date: 2, ��9 /`z I Date: 31 o8 I11
is-
Dillon Roofing LLC. 1450 SE Grapeland Ave (772)-494-9539
Port St. Lucie FI,34952
i
Scope of Work:
1. Tear off existing roof downto sheathing and haul off all debris.
2. Remove gutter
3. Nail off sheathing to code as needed.
4. Install 1 ply of Polyglass SAV straight to deck on flat deck.
i
S. Install 1 ply of Polyglass SAP on flat deck
6. Install#30 underlayment nailed off to code.
7. Install Aluminum Drip edge,.
i8. All plumbing flashings to be released with new.
9. Install architectural shingles to manufactures specifications.
10. Dillon Roofing LLC.5-year workmanship warranty upon completion.
I
Main house total amount:$8,850.00 I
Garage:$4,100.00
Total Contract Amount:$12,950.00
Terms:35%deposit 30%upon tear off,25'/;upon delivery of roof materials,and 10%upon completion.
Notes
• All woodwork to be on a time and material basis at a rate of$75.00 per man-hour and the cost of materials.
• IF REQUIRED:As per updated Florida Building Code;When a roof covering on an existing site-built single-
family residential structure that has an insured or a taxation assessed value of$300,000 or more is removed
and replaced,roof to wall connections shall be improved up to 15916 of the cost of re-roofing.
• Existing driveway to be protected with plywood during tear-off and loading phases.However,Dillon Roofing
LLC.will NOT be responsible for anV damage that might occur.
• Dillon Roofing LLC_ is not responslble for any roof arstructural related issues that may occur as a result combining
sealed attic system with an impermeable roof covering.
• Exclusions: Asbestos abatement if necessary,painting,wood replacement,concrete repair and replacement,
gypsum deck repair and replacement,metal deck repair and replacement.
i
i
I
i
Initials
i
Dillon Roofing LLC. 1450 SE Grapeland Ave (772)-494-9539
Port St.Lucie FI,34952
Florida Building Code Online https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDq...
i
1W I
Business
t
1 . al Rgu lation
1305 Home 1 Log In I User Registration Hot Topics ' Submit Surcharge Stats&Facts I Publications FBC Staff BCIS Site Map
bUSERa
Product Approval
:
Public User
- E�'`Pa�tnYPa�t�m
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL12328-R8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
I
Archived ❑
Product Manufacturer TAMKO Building Products, Inc.
j Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
i
Subcategory Underlayments
i
Compliance Method Evaluation Report from a Florida Registered Architect or
Florida Professional Engineer
I ❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden P.E.
L1 Validation Checklist- Hardcopy Received
1 of 4 4/23/2018, 12:35 PM
Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDq...
Certificate of Independence FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAI
Underlayments final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4869 2016
ASTM D6380 2003
TAS 103 1995
I
Equivalence of Product Standards
Certified By
i
Sections from the Code
I
I
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
jDate Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
j Other:See evaluation report for limits of,use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.2 ASTM Tile Underlayment Coated organic underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
iCreated by Independent Third Party: Yes
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits of Use Installation instructions
Approved for use in HVHZ: No FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
2 of 4 4/23/2018, 12:35 PM
Florida Building Code Online https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDq...
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.4 Moisture Guard A self-adhering modified bitumen underlaymei
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva]
Underlayments final.pdf
Created by Independent Third Party: Yes
' 12328.5 No. 15 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.6 No. 15 UL Asphalt saturated organic felt
i` Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.7 No. 30 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.8 No. 30 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval
Underlayments final.pdf
Created by Independent Third Party: Yes
i
1 12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlaymei
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval F
3 of 4 i 4/23/2018, 12:35 PM
1
CREEK
Certificate ofAuthorization bur 29824
L.yyL•yy 17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES,LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6P EDITION(2017)
Manufacturer. TAMKO BUILDING PRODUCTS,INC. Issued October 19,2017
P.O.Box 1404
Joplin,MO 64802
(417)624-6644
httpi//www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380,Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
i
TAMKOO ASTM Tile ASTM D 6380,Class M,Type II underlayment constructed from an organic felt saturated
i Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO®Master ASTM D 6380,Class S,Type IV underlayment constructed from an organic felt saturated
i Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKO®Moisture Self-adhered,ASTM D 1970,fiberglass reinforced,modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film an the adhesive side and
removable selvedge release tape.
TAMKOO No.15 ASTM ASTM D 226,Type 1 undedayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO®No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAM KOO No.30 ASTM ASTM D 226,Type 11 undedayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO®TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103,rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKOaTW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 616203. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
i
II
1
I
{
r.r i' TAMKO BUILDING PRODCUTS,INC.
CREEK K TAMKO Underlayments
TECHNICAL SERVICES,LLC
TAMKOS TAM-FELT Alternate to ASTM D 226,Type I and Type 11 undedayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturers installation instructions, the FBC, and the
requirements below.
I
j Deck substrates shall be clean,dry,and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underiayment application.
I
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8'gap at abutting
joints.
! The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKOS TW Metal and Tile Underlayment and TAMKO®TW
Undedayment shall be 40`F.
j b) The minimum application temperature df TAMKOS Moisture Guard®shall be 35°F.
j The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOS ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underiayments shall be exposed in accordance with the manufacturers recommendations, but in no case shall
exposure exceed 30 days.
Exception:TAMKOS TW Metal and Tile Undedayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underiayment to the roof deck.
Allowable Roof Coverin s:
Metal Roof Mineral Wood.
' "Asphalt Panels and Sud'acedltoll Shinglesand. Slate Clay and
i
Underlayment Shingles Shingles Roofing Shakes Shin les ConcreteTile
TAMKOS ASTM Slate Y, N N N N Y
Surfaced Roll Roofing
TAMKOS ASTM Tile N N N N N Y
Underlayment
TAMKOSMaster Smooth Y, N N N N N
TAMKOSMoisture Guard® Y N N N N N
TAMKOS No.15 ASTM
Asphalt Saturated Organic Y Y Y Y2 N N
Felt
TAMKOS No.15 UL Asphalt Y Y Y Yz Y N
Saturated Organic Felt
TAMKOS No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKOS No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOS TW Metal and Tile Y Y N N N Y
Underlayment
TAMKOSTW Underlayment Y Y N N N N
TAMKOSTAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001A FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
f
I
I
i
i
CREEK TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation_
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published
application instructions. Where discrepancies exist between these sources,the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave,and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturers application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
I
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(rST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 20D3(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6D49) TAP-019-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
I
I
I
I
I
I
����� TAMKOBUILDINGPRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R.Priest,P.E.have demonstrated compliance with the Florida Building
Code,6"Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
11111111111
G� P RY R. p 9,
.�
No 74021
'33Z
STATE OF
'O'� < Zachary R.Priest,P.E.
�i' O R �� Florida Registration No.74021
S,ON All� % , Organization No.ANE9641
I
j CERTIFICATION OF INDEPENDENCE
Ii
I CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest In any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
{ Zachary R.Priest,P.E.does not have,nor wig acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
+I Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity invoked in the approval process of the product.
t
4
END OF REPORT
TBP14001A FL12328-R6 Page 4 of
This evaluation report is provided for State of Florida product approval under Rule 61G20: . The manufacturer shall notify CREEK
i Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not e>press nor imply waminty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
I
i
i
i
t
Florida Building Code Online https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQWtD...
Business: ® o . ® r .
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats&Facts Publications I FBC Staff I BCIS Site Map
Florida
pr
� Product Approval
USER:Public User
0.��a�y*r�SOI I,4Ciy
F<RGY,.�.YP2r
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL10674-1113
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or
Florida Professional Engineer
Lil Evaluation Report- Hardcopy Received
I Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.odf
I
1 of 2 4/23/2018, 12:56 PM
Florida Building Code Online https://floridabuilding.org/pr/pr app_dtI.aspx?param=wGEVXQwtt)...
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab, laminated,starter and hip
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R13 II 2017 10 FINAL ER OC AE
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE- 5916E
Design Pressure: N/A Created by Independent Third Party: Yes
1 Other: Refer to ER, Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC A
SHINGLES FL10674-R13.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
i
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refr,
i Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records reque
electronic mail to this entity.Instead,contact the office by phone or by traditional maid.If you have any questions,please contact 850.487.13
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with
they have one.The emaits provided may be used for official communication with the licensee.However email addresses are public record.If y.
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you.
Chapter 455,F.S.,please click here.
i
Product Approval Accepts:
OcChz'ck i-
I
7 Credit Card
Safe
2 oft 4/23/2018, 12:56 PM
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
Q0TR1NrrYJERD353 CHRISTIAN STREET,UNIT 478 OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-118
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6"t Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
j its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: 4q�Srlgrnrfq�"
�`.'�:;?G� Ems.•..;,':
C�: •.*
Robert J.M.Nieminen,P.E. '-•� The facsimile seal appearing was authorized by Robert
NxvFlorida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
i
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
I
i
i
QOTRINIWIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
I
3. REFERENCES:
I
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
1 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shinsles:
4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition® Duration% Duration® Premium Cool, TruDefinition® Duration® Designer Color
Collection, TruDefinition®Oakridge', Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridse Shinsles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge,WeatherGuard HP Hip&Ridge Shingles, ProEdge Hip & Ridge
Shingles and Dura Ridge'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RB
Certificate of Authorization#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
I
I
QOTRINITYIERD
5.4 Wind Classification:
j 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasa = 150 mph (Vnit = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph(Vult=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609,4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
I
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
j Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shinales:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
{ minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuardo HP shingles require minimum six(6)nails per shingle.
➢ Devonshire"m shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation)imitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck Feltundedayment Deck Selbodhered
Weathedockm
Self-adhered undedaymerd
WeatherLocko
undedayment
Drip edge
edge Drip edge
g
Nails locatedNags located
2'�"Irom cave
2=3"from eave
Install fust Self-sealing adhesiveSelfrteating adhesive
Starter Strip positioned along eave �stal reo
with6' mveerSt
dnpFNs pasitionedalongeave
shingle with '•.,, \
S"removed `\
Starter STrip shingle overhangs eaves and rakes'/�—'/i Starter Stdp Plus overhangs eaves and rakes 1141-3W
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate DfAuthorization A9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
1
F)o
-rRINrn�ER®
6.2.6 Minimum Nailing—Classic®&Supreme:
I
t
Normal Mansard or Area para Normal Mansard or Area pard
Wind AreasHigh Wind desvenas y Wind Areas High Wind desvones y
Area pare Weintos normales Areas vientos fuertes Area para vlentos normafes Areas vientos faartas
�1- z- B 2• r� �` (A) 1•1 r1• 2• lei z' T.
7T 121 ,21
W Exposure 5 511"Exposure
Exposieidn. Exposieidn
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip Sealant strip
La IN de seliador /is tka de sellador
J( NOW
•.---i .----.! • •_..-.•
r
r
Standard Fastening Pattern 6-Nail Fastening Pattern
I
Sealant strip _
La tka de settador
R.E--►.4-�• •F----0 4 pe
B Yf 8 Yf 8 Yf' 8 Yf
r
r �c
t
I Asphalt roofing cement
Cemento de techo do Wado
I
Mansard or Steep Slope Fastening Pattern
I
I
I
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8
Certificate ofAethorization 119503 6EDITION(2017)FBC NON-HVHZ EVALUATION F1.30674-1113
Owens Coming Asphalt Roof Shingles Revision 5:10/09/2017
Page 4 of 8
TRINITY I ERD
6.2.8 Minimum Nailing—Devonshire"":
I
I
I
1.. 7" 8n 8" H-- 8 •I off I 1
n
Nei 4'
Tdews
----.- Nails
• r r e• T r
5-5/8eexposure Sealantlocation
Exposicibn de 5.5/8 pulp Ubicacibn del sellador et:
Ten 1"Spots of Asphaft Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6'.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition®
Duration"Designer Color Collection:
4-Nail Fastening Pattern 6-Nail Fastening Pattern
SureNaastastemme area width SaeNm0fastening SIN Wdth.
Nail.lypleat NA 7ypWt
r 1r 1r r 1r I I 12• �^
•]awCmnOlul4al • G o..V '.O�m TVMtYo.. • PA.T�v4lmNY •....• T *o.a "•O.®fs.mNTveNY. •.
s-ua•BSI6^ tM
I
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SureNallfl festomng eras wldm
Nae,Typkal
r 12- I 1r 1-
wsca.wl..a. . ...ol....o •
I
e•f>s•s6m^
T,
Foul-Spots ofAsphah RoofNg cement
Mansard or Steep Slope Fastening Pattern
I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate ofAuthorization#9503 6TM EDITION(2017)FBC NON•HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
i
I
QOTRINITYIERD
6:2.1 Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
4 Nall Pattern 6 Nail Pattem
Fsgaema con 4 davos Fs4uema con 6 davos
r r
`, 1• '1 V P
12.
A A . .
5578"Exposure Nalls 5 578"Exposure NaUs
Expos[Wn de 5 518 pufg. Clavos ExposidiFde5618putg 5578"Exposure Claws 558"Exposure
Exposfeldn de W pufg. Exposfdda de 6618 pufg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21.12
S—NNwhsto.]gmen wfmh
NA TWcd
� 8-UBn=1
�Z•
Four 1"SpoU olAsphNl Roofing Cement
11 Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
I
I■ t silollb'61de Vbw
z.�!k�li Lend
IQs. �•s'a' .•:••
.i:• :�.4• FW'Wm 7hu&Nil Itis
Ctw ira w 64 if r a i f!jdd 6.
I
I
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118
Certif7cate of Authorization/9503 6'"EDITION(20171 FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
i
i
TRINITY ER®
6.3 Hip&Ridge Shingles:
6:3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge"* Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R90S.2.5."Staples are not permitted.
6.3.3 Minimum Nailing_Berkshire's Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
E-- Fmeauogwma
01reiYbn TvPtliew'; SitleView
.
4 Nans -T— Nails
j"'�
a I ! A• TOFLaninalCYl. r 1
A , Fiece
'.l4 p. I i 1" .r •
A I
A I I I
i
1 -—� g t
�Ex{iostrte �1;
VI
i
i
i
6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge:
Fig.i4. 9?
Fig.C"l9ip;&Ridge.Shingle Fasteniiig`� '
Prevanntg Wind - Topftw'
E'—aitebtgn A
Nails".,`-.• T '4
I 1
A I j Nglis Nails
44 ! 2
2'•
A I I l t
i' 'i' ♦ W
I Exposure
S'. a posure
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate ofAuthorizatian#9503 6'N EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
! Page 7 of 8
.J T•R1N11Y ER®
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard —tt•_y
Wind Direction SealantStdp
Pattern
ning
6'Exposure ~
ty I Sealant
Fasten7'h'. 7y= 6"Exposure
•St0 Br5 wit
Roof Cement
6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
=ifn®Wind Diracdm Vue ennpi o
Dirottlaa6DW1Mntadxoat VistaI�- .euperin I')
Dirocdtrt dal rknto pradornimnto
Nu'1
Mal;
25 r • Ovmna Coming:SurcNen' • a0�1O
ClCaiot�
A
J I i + alm�
V I�cs
A 12"--
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2,7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
1I 9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 OA
requirements.
i
10. QUALITYASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
i - END OF EVALUATION REPORT=
I
i
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118
Certif&ate ofAuthorization#9503 6'EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8